Brand: Teledyne (Detcon)
Teledyne S02312 SP3X FC Free Chlorine Sensor, Low Range 0.5-20ppm
Description
Overview
The Teledyne S02312 is a genuine SP3X FC free chlorine sensor built on Teledyne Analytical Instruments’ SP3X Smart Sensor platform, configured for low-range measurement from 0.5 to 20ppm with a PVC sensor body, flanged mounting configuration, and a 4ft integral cable terminating at the transmitter connection. The SP3 and SP3X Smart Sensor family covers a wide range of liquid measurement parameters, including pH, ORP, conductivity, dissolved oxygen, and free and total chlorine, using an interchangeable amperometric sensing electrode design that shares a common mechanical and electrical platform across the product line.
Backed by manufacturer datasheet documentation, Seven Star LLC supplies the Teledyne S02312 free chlorine sensor to municipal water treatment plants, desalination facilities, and industrial process water systems across Muscat, Sohar, and Salalah, supporting continuous disinfection monitoring programs that protect public health and process water quality throughout the region.
Operating Principle
The Teledyne S02312 measures free chlorine concentration using an amperometric, membrane-covered polarographic sensing method. A polarizing voltage is applied across the sensor’s working and counter electrodes, and free chlorine diffusing through the selective membrane generates a current proportional to its concentration in the sample water. Because the measurement is diffusion-limited by the membrane rather than dependent on sample flow turbulence, the SP3X platform delivers stable, repeatable readings across the 0.5–20ppm low measurement range specified for this sensor variant.
The sensor communicates digitally with compatible SP3X-ready transmitters such as the Teledyne LXT-380, which automatically recognizes the connected sensor type and configures its menus and calibration routines accordingly, reducing setup time and the potential for configuration errors. This digital smart-sensor architecture also supports on-sensor storage of calibration history and electrode life data, giving operators visibility into remaining sensor service life without needing to reference separate paper logs.
Across the broader SP3X free and total chlorine electrode family, the sensing element is built around a gold measuring cathode and a silver/silver chloride reference anode held behind a selective PTFE membrane, with a typical T90 response time on the order of two minutes once the membrane has equilibrated to a new sample condition. Because amperometric output current is temperature-dependent, the compatible transmitter applies automatic temperature compensation – typically on the order of several percent per degree Celsius for chlorine measurement – using the integral temperature element to hold the displayed reading stable as process water temperature drifts through the day. Supported calibration workflows include automatic two-point calibration against buffer or standard solutions, single-point standardization against a grab sample analyzed by DPD or another referee method, and manual entry of laboratory results, giving plant chemists flexibility in how they maintain traceability to their regulatory chlorine residual monitoring program.
Engineering Design of the Teledyne S02312
The Teledyne S02312 is constructed with a chemically resistant PVC body suited to continuous immersion in chlorinated water and wastewater streams, with a flanged mounting configuration that allows secure installation into flow cells, sample chambers, or in-line tees without additional adapter hardware. The 4ft integral cable provides a sealed, factory-terminated connection between the sensor and its transmitter, eliminating field-wiring splices that can introduce moisture ingress or signal noise over time.
Routine maintenance follows the SP3X platform’s standard membrane and electrolyte replacement procedure: the sensor is removed from its mounting, the membrane cap is unscrewed, the electrode surface is inspected and cleaned, fresh electrolyte and a new membrane cap are installed, and the sensor is recalibrated against a known chlorine standard before being returned to service. This modular maintenance approach keeps ongoing operating costs low compared to sensors requiring full electrode replacement at each service interval. Electrolyte and membrane service intervals are concentration-dependent: sensors operating in the lower part of their range typically need a refill on an annual cycle, while continuous duty at the higher end of the 0.5–20ppm band can call for membrane and electrolyte renewal as often as every six months to keep the diffusion-limited response within specification.
Key Features
The Teledyne S02312 free chlorine sensor is engineered to deliver dependable low-range chlorine monitoring for water treatment applications:
- Amperometric polarographic sensing provides stable, membrane-limited free chlorine measurement from 0.5 to 20ppm.
- Chemically resistant PVC body withstands continuous immersion in chlorinated water and wastewater streams.
- Flanged mounting configuration simplifies installation into flow cells and sample chambers without adapters.
- 4ft integral cable with factory-sealed termination eliminates field-wiring splices and moisture ingress points.
- SP3X Smart Sensor digital communication enables automatic transmitter configuration and reduced setup time.
- On-sensor calibration history storage improves maintenance planning and traceability for compliance reporting.
- Modular membrane and electrolyte replacement keeps ongoing maintenance costs lower than full-electrode designs.
- Supported by Seven Star LLC’s technical support for water treatment plant maintenance teams.
Industrial Applications
The Teledyne S02312 free chlorine sensor serves municipal and industrial water treatment facilities that require continuous, low-range chlorine residual monitoring for disinfection control and regulatory compliance. Typical applications include potable water treatment plant clearwell and distribution monitoring, seawater and brackish water desalination plant post-treatment disinfection verification, and cooling water and process water systems where chlorine dosing must be tightly controlled to balance disinfection efficacy against corrosion and discharge limits.
Working closely with plant engineers in the region, Seven Star LLC distributes this sensor to municipal utilities, desalination plant operators, and industrial water treatment contractors across the Sultanate of Oman, Muscat, and the Sohar and Salalah economic zones. Contact Seven Star LLC for a quotation and current lead time for the Teledyne S02312 SP3X FC Free Chlorine Sensor, Low Range 0.5-20ppm.
Technical Specifications
The table below summarizes the key specifications relevant to the Teledyne S02312 SP3X FC free chlorine sensor.
| Parameter | Specification |
|---|---|
| Model | Teledyne S02312 |
| Sensor Platform | SP3X Smart Sensor |
| Measured Parameter | Free Chlorine (FC) |
| Measurement Range | 0.5–20ppm (low range) |
| Sensing Method | Amperometric, membrane-covered polarographic |
| Body Material | PVC |
| Mounting | Flanged |
| Cable Length | 4ft integral, factory-sealed termination |
| Compatible Transmitters | SP3X-ready Teledyne transmitters (e.g., LXT-380) |
| Electrode Construction | Gold cathode, silver/silver chloride anode, PTFE selective membrane |
| Typical T90 Response | ≈ 2 minutes |
| Calibration Methods | Automatic two-point, single-point standardization, manual entry |
Request a Quote for Teledyne S02312 SP3X FC Free Chlorine Sensor, Low Range 0.5-20ppm
Seven Star LLC invites water treatment plant engineers and procurement teams across Oman and the GCC to submit a formal RFQ for the Teledyne S02312 SP3X FC free chlorine sensor. With fast quotation turnaround and technical support, we supply SP3X sensor family components on request, provide technical datasheets on request, and connect customers directly with our instrumentation division for water treatment application support. Contact Seven Star LLC today to confirm availability, lead time, and pricing for your disinfection monitoring program.
Related Products
Datasheets & Documents
- Brochure Teledyne SP3/SP3X Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Two different product lines sit behind the Teledyne name on this page: process gas analyzers and sensors from Teledyne Analytical Instruments, and fixed gas and flame detectors from Teledyne Gas and Flame Detection, the home of the Detcon name. Seven Star LLC lists Teledyne oxygen and moisture analyzers, analyzer circuit boards, replacement sensors and Detcon detectors, and sources them by part number for plants and utilities in Oman.
Teledyne analyzers, sensors and Detcon detectors listed
The listing is weighted toward spare parts for installed analyzers:
- 3000 series oxygen analyzers, such as the 3000RS, with PCB assemblies for Model 3000 and 3020M units and the P01962 power supply, which replaces the obsolete B70284
- 8800B trace moisture analyzer from the 8800 series
- B71875 InstaTrace oxygen sensor
- Liquid analysis parts: the CP03030 pH sensor cartridge and the S02312 free chlorine sensor
- Fire and gas: the Spyglass SG50-F-IR3 triple IR flame detector, listed here under Teledyne Detcon, and the iTrans 2 fixed gas monitor
Where Teledyne analyzers and Detcon gas detectors are used
Teledyne oxygen analyzers measure trace and percent oxygen in nitrogen, hydrocarbon and inert gas streams, for example on air separation units, blanketing systems and gas pipelines. Trace moisture analyzers serve instrument air and dry gas service. Teledyne Detcon gas detectors and flame detectors are used on wellsites, compressor stations, tank farms and water treatment plants in the GCC, wired to a controller or the plant safety system.
Ordering Teledyne parts: what we need
Teledyne Analytical Instruments parts are identified by a letter and number code, such as C70043A or B71875, and by the analyzer model and serial number. Send all of them. Oxygen sensors are selected by class for the background gas and range, so name the sample gas composition and the analyzer model. For a Teledyne Detcon gas detector or flame detector, send the model and full part number from the label, the target gas and range, output, and the area approval required. We check each code against the manufacturer's documentation and propose the listed replacement when a part has been superseded.
Browse Teledyne (Detcon) products by category: Gas Analyzer Accessories, Fire & Gas Detector, Liquid Analysis Sensors, Gas Analyzer Systems.
Related products
Frequently Asked Questions
The S02312 is the low-range SP3X FC free chlorine sensor variant, covering 0.5 to 20ppm, suitable for potable water and process water applications where chlorine residuals are maintained at lower disinfection levels.
The S02312 uses the SP3X Smart Sensor digital platform and is compatible with SP3X-ready Teledyne transmitters, which automatically recognize the sensor type and configure calibration menus accordingly.
Maintenance intervals depend on water quality and fouling potential, but the sensor uses a modular membrane and electrolyte replacement procedure that keeps routine servicing quick and low-cost compared to full electrode replacement designs.
Yes, the PVC sensor body is chemically resistant to continuous immersion in chlorinated seawater, brackish water, and process water streams typical of desalination plant post-treatment monitoring.
Yes, Seven Star LLC is an experienced supplier of Teledyne (Detcon) analytical and water treatment products across the Sultanate of Oman and the GCC.