Brand:

ifm PN7093 Pressure Sensor with Display

Description

Overview

ifm PN7093 is a ceramic-capacitive pressure sensor with an integrated red-green switch-point display, engineered by ifm electronic for compressed air, hydraulic, and general industrial pressure monitoring from 0 to 25 bar (0…362 psi). The ifm PN7093 combines two configurable PNP/NPN switching outputs with an IO-Link communication interface on a single M12 connector, giving plant engineers both simple discrete switching and full digital process-value access from one compact stainless steel body with a G1/4 internal (female) process thread.

Working closely with plant engineers in the region, Seven Star LLC proudly supplies the ifm PN7093 pressure sensor to facility engineers, system integrators, and OEM panel builders across Oman and the wider GCC, backed by technical support with selection for critical process lines.

Measurement Principle

The ifm PN7093 uses a ceramic-capacitive measuring cell in which process pressure deflects a rugged ceramic diaphragm bonded to a fixed ceramic counter-electrode. The resulting change in capacitance is converted by onboard electronics into a linear, temperature-compensated output signal. Because the ceramic diaphragm has no metallic bourdon elements in the pressure path, the sensor tolerates overload and pressure-spike events far beyond its nominal range without permanent zero-point drift, delivering repeatability of better than ±0.1% of the span (with temperature fluctuations below 10 K) within the −25…80°C operating window.

Two independent switch points are freely programmable via the front-panel keys or over IO-Link, each assignable as a hysteresis window, single-point switch, or window function, and each mapped to one of the two PNP/NPN outputs. In practice this means no moving parts are exposed to the media, no pressure drop is introduced into the line, and there is no risk of media contamination from lubricants or seal wear – a critical advantage for the clean compressed-air and hydraulic circuits common in Omani manufacturing and desalination plants.

Beyond its published measuring span, the ifm PN7093 carries a nominal pressure rating of 150 bar and a minimum burst pressure of 350 bar, giving hydraulic power units and compressor discharge lines a substantial safety margin against transient pressure spikes and water-hammer events. The sensor additionally tolerates vacuum conditions down to −1 bar, making it equally suitable for suction-side monitoring on pumps and vacuum-assisted process equipment, and its wetted parts – 1.4404 stainless steel, technical ceramic, and an FKM seal – resist the mineral oils, water-glycol hydraulic fluids, and compressed air commonly encountered on Omani industrial sites without seal degradation or long-term drift.

Engineering Design of the ifm PN7093

The ifm PN7093 is built into a housing with a 1.4404 stainless steel process connection, rated IP65/IP67, with a G1/4 internal (female) process connection sized for direct manifold or hydraulic block mounting. The rotatable housing allows the display to be oriented for readability regardless of installation angle, and the large two-color (red/green) segment display shows the live process value while indicating switch-point status at a glance – eliminating the need for a separate gauge on the same tapping point.

Electrical connection is made through a single M12x1 4-pin connector carrying both switching outputs and the IO-Link (COM2, 38.4 kBaud) interface, simplifying cabling to PLC digital inputs or an IO-Link master for SCADA-level diagnostics. Supply voltage is 18…30 VDC, and the sensor’s compact profile – 34 mm in diameter and 90.7 mm long – suits tight panel and skid layouts where space around hydraulic manifolds or compressor headers is limited. The unit weighs just 0.235 kg complete, its housing combining a 1.4404 stainless steel wetted section with a glass-fibre-reinforced PBT/PC shell, and it carries DIN EN 60068-2-6 vibration resistance (20 g, 10…2000 Hz) and DIN EN 60068-2-27 shock resistance (50 g, 11 ms) ratings that matter on compressor skids and vibrating machine-tool bases where lighter-duty sensors work loose or fail prematurely. The M12 connector uses gold-plated contacts for long-term corrosion resistance in humid, coastal GCC environments, and the ifm PN7093 carries CE marking to the DIN EN 61000-6-2/6-3 EMC standards together with UL recognized-component status, easing specification into both European- and North American-engineered skids supplied into the region.

Key Features

The ifm PN7093 pressure sensor delivers the accuracy, robustness, and connectivity that Oman’s process and OEM industries expect from a modern pressure sensor with display.

  • Ceramic-capacitive measuring cell rated 0…25 bar with immunity to overload and pressure-spike damage.
  • Two freely configurable PNP/NPN switching outputs for independent high/low or window alarm functions.
  • Integrated IO-Link (COM2) interface for continuous digital process data and remote parameter configuration.
  • Bright red/green 4-digit display for local switch-point status and process-value readout.
  • Wetted parts in 1.4404 stainless steel, ceramic and FKM, with G1/4 internal (female) thread for direct hydraulic and pneumatic mounting.
  • IP65/IP67-rated housing suited to washdown and outdoor equipment yards.
  • Wide −25…80°C ambient operating range for both indoor plant rooms and exposed GCC rooftop installations.
  • Repeatability better than ±0.1% of the span ensures dependable long-term switching accuracy without recalibration drift.
  • Burst pressure rated to 350 bar and vacuum resistance to −1 bar provide a wide safety margin for hydraulic-spike and suction-side applications.
  • DIN EN 60068-2-6 vibration and DIN EN 60068-2-27 shock ratings, plus a gold-plated M12 connector, suit compressor and machine-tool duty.

Industrial Applications

The ifm PN7093 is widely specified for compressor stations, hydraulic power units, pneumatic control panels, and machine-tool cooling circuits, where its dual-output switching plus IO-Link readout simplifies both machine safety interlocks and predictive-maintenance data collection. Typical deployments in the Sultanate of Oman include compressed-air header monitoring in manufacturing plants, hydraulic clamping-pressure verification on production lines, and pump-protection switching on RO desalination skids where dry-run or over-pressure conditions must trip a PLC input instantly.

With fast quotation turnaround and technical support, Seven Star LLC distributes the PN7093 to industrial buyers throughout Muscat, the Sohar and Salalah economic zones, and neighboring GCC states, supporting district cooling plants, food and beverage packaging lines, and marine terminal utilities that depend on dependable local-display pressure switching. Our technical team helps integrators confirm availability and lead time when a PN7093 needs replacing on a live line.

Technical Specifications

The table below summarizes the core specifications relevant to sizing and installing the ifm PN7093 pressure sensor.

Parameter Specification
Model ifm PN7093
Measuring range 0…25 bar (0…362 psi / 0…2.5 MPa)
Measuring principle Ceramic-capacitive
Repeatability < ±0.1 % of the span (with temperature fluctuations < 10 K)
Outputs 2 x PNP/NPN switching, configurable + IO-Link (COM2)
Display 4-digit, red/green switch status indication
Process connection G1/4 internal (female), stainless steel
Housing material Stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Electrical connection M12x1, 4-pin connector
Supply voltage 18…30 VDC
Ambient temperature −25…80°C
Operating pressure rating 150 bar (2175 psi)
Burst pressure 350 bar (5075 psi) minimum
Vacuum resistance −1 bar
Wetted parts 1.4404 stainless steel, ceramic, FKM seal
Current consumption < 35 mA
Weight 0.235 kg
Protection rating IP65 / IP67
Vibration / shock resistance DIN EN 60068-2-6 (20 g) / DIN EN 60068-2-27 (50 g)
Certifications CE (DIN EN 61000-6-2/6-3), UL recognized component
Switch point accuracy < ±0.5 % of the span
Characteristics deviation < ±0.25 % of the span (BFSL) / < ±0.5 % (limit value setting)
Long-term stability < ±0.05 % of the span per 6 months
Response time < 3 ms
Switching frequency < 170 Hz
Output current rating 150 mA per switching output (200 mA up to 60 °C, 250 mA up to 40 °C)
Storage temperature -40…100 °C
Dimensions Diameter 34 mm, length 90.7 mm

IO-Link Operating Modes and Device IDs

ifm lists the PN7093 under the type designation PN-025-RER14-QFRKG/US/ /V. Its IO-Link interface is revision 1.1 with COM2 transmission (38.4 kBaud), supports SIO mode and needs a class A master port. Two operating modes with different device IDs are available. In the factory setting (DeviceID 402) the sensor follows Smart Sensor Profile SSP 0, sends a 14-bit pressure value plus two binary switching bits, resolves 0.1 bar over IO-Link and has a minimum process cycle time of 2.3 ms.

The second mode, called Status_B High Resolution (DeviceID 600), follows Smart Sensor Profile SSP 3.1 as a measuring sensor. Here the cyclic process data consists of a 16-bit pressure value, four device status bits and two binary switching bits, the IO-Link pressure resolution improves to 0.01 bar and the minimum process cycle time is 3 ms. When replacing a unit or preparing a master configuration, check which DeviceID the existing project expects, because the two modes use different process data layouts.

Switch Point Ranges and Output Loading

The set point SP can be adjusted from 0.2 to 25 bar and the reset point rP from 0.1 to 24.9 bar, in steps of 0.1 bar, with a minimum difference of 0.2 bar between them. Switch-on and switch-off delays are programmable from 0 to 50 s. Each switching output is rated for 150 mA continuous current, rising to 200 mA up to 60 °C and 250 mA up to 40 °C, with a maximum voltage drop of 2.5 V. ifm states that a restrictor element is not integrated but can be retrofitted, and that the unit suits group 2 fluids under the pressure equipment directive.

ifm PN7093 – Frequently Asked Questions

What type of sensor is the ifm PN7093?

A pressure sensor with display that uses a ceramic-capacitive measuring cell.

What outputs does it have?

Two switching outputs (PNP/NPN) and IO-Link on a single M12 connector.

How much overpressure can it withstand?

It has a nominal pressure rating of 150 bar and a minimum burst pressure of 350 bar, and tolerates vacuum down to -1 bar.

What is the process connection?

G1/4 internal (female) thread, with wetted parts in 1.4404 stainless steel, ceramic and FKM.

Where can I buy the ifm PN7093 in Oman?

Seven Star LLC supplies the ifm PN7093 in Oman and the GCC. Request a quote below for price and lead time.

Request a Quote for ifm PN7093 Pressure Sensor with Display

Seven Star LLC invites facility engineers and procurement teams across Oman and the GCC to submit a formal RFQ for the ifm PN7093 pressure sensor. With engineering support in Muscat, we supply on request with lead time confirmed at quotation, provide the full technical datasheet on request, and connect buyers directly with our instrumentation division for application sizing, IO-Link integration guidance, and technical support.

Related Products

Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Founded in 1969 and based in Essen, Germany, ifm builds industrial sensors and control components for machine and process automation, from proximity switches to pressure and distance sensors. Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.

ifm sensors listed on this page

ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:
  • O1D100: laser distance sensor for position and distance measurement
  • PN7093: pressure sensor with local display
  • NG5021: inductive proximity sensor with NAMUR output
Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.

Ordering ifm sensors: what we need

Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.

Frequently Asked Questions

What pressure range does the ifm PN7093 measure?
The ifm PN7093 measures 0 to 25 bar (0 to 362 psi) using a ceramic-capacitive measuring cell, with a repeatability of ±0.1% of the span within its -25 to 80°C operating range.
Does the PN7093 support IO-Link communication?
Yes. In addition to two configurable PNP/NPN switching outputs, the PN7093 carries an IO-Link (COM2) interface on the same M12 connector, allowing continuous digital process-value transmission and remote parameter configuration from an IO-Link master.
What process connection and materials does the PN7093 use?
The PN7093 has a G1/4 internal (female) thread stainless steel process connection and a fully stainless steel wetted housing, rated IP65/IP67, suitable for hydraulic, pneumatic, and washdown environments.
Can the PN7093 replace an older analogue pressure switch?
Yes. Its dual PNP/NPN switching outputs can directly replace legacy mechanical pressure switches on existing panels, while the added IO-Link channel provides a straightforward upgrade path to digital monitoring without rewiring the switching circuit.
Is Seven Star LLC an experienced supply partner for ifm products?
Yes, Seven Star LLC is an experienced supplier of ifm in Oman and the GCC, supplying PN7093 sensors on request with local technical support.