Panametrics AquaTrans AT620 Two-Channel Clamp-On Flowmeter
Description
AT620: two-channel AquaTrans flowmeter from Panametrics
The Panametrics AquaTrans AT620 is presented as a next-generation clamp-on ultrasonic flowmeter for jobs that need flexibility, redundancy and confidence in the reading. It builds on the AT600 platform but allows a single small transmitter to run two independent measurement paths, either across two separate pipes or as two paths on one pipe. That halves the hardware for a two-line site and, on a single line, offers a second signal that can take over if the first path is interrupted or degraded. Like its predecessor it is aimed at industrial water and wastewater applications in full pipes and uses patented correlation transit-time technology with solid couplant, so there is no routine maintenance.
What the second channel gives the AT620 user
- Dual path on a single pipe: velocity is calculated from both paths together, improving immunity to swirl, asymmetry and upstream piping effects.
- Built-in redundancy: if one path loses signal, the other keeps delivering a flow reading.
- Two pipes, one transmitter: each signal gives an independent flow measurement for its own pipe, lowering installation cost.
- Selectable single-channel, two-channel one-pipe or two-channel two-pipe system codes (C1 or C2).
- Pipe sizes from 0.5 in to 300 in (15 mm to 7600 mm).
AT620 data sheet values
| Parameter | AT620 |
|---|---|
| Channels | One or two: one path, two paths on one pipe, or one path on each of two pipes |
| Accuracy | 1% of reading for pipes 2 in (50 mm) and larger above 1 ft/s; 2% below 2 in; 0.5% in field calibration |
| Repeatability and range | 0.2% of reading; -40 to 40 ft/s (-12.19 to 12.19 m/s); rangeability 400:1; higher velocities by consultation |
| Enclosure | Epoxy-coated aluminum Type 4X / IP67; 6.6 x 5.0 x 2.4 in; 3.5 lb (1.5 kg) |
| Display | 128 x 64 graphic LCD with six-button keypad and green or red indicator |
| Supply | 85 to 265 VAC or 12 to 28 VDC; 5 W normal, 10 W inrush |
| Outputs | 4-20 mA with 600 ohm load; frequency, pulse or alarm; HART 7.5; Modbus RS485, all isolated to 1500 VDC |
| Transducer temperature | -40 to 302 F (-40 to 150 C) standard; optional -328 to 752 F |
| Fixture | Anodized aluminum or stainless steel, with stainless strapping |
| Certification | CE, UL, CSA |
How AT620 differs from AT600
The one concrete change is channel count: AT620 offers C1 single-channel and C2 two-channel systems where the AT600 offers C1 only. The AT620 order string adds a second transducer system, second pipe size, second pipe units and second cable length (letters G to J in the datasheet), and lists extra cable lengths of 160 ft (50 m) and 230 ft (70 m) beside the 10, 25, 50, 100 and 300 ft options. It also adds the C-RS 2 MHz CR20 and CR20SUB transducers for small pipes. The AT600 lists MCERTS (UK) among its certifications, whereas the AT620 datasheet lists CE, UL and CSA.
Reading the AT620 order code
The string A to P plus Z begins with model AT620, then the meter system C1 or C2, the first transducer system (0 for spare electronics only, AT05, AT10, AT20, CFLP, CFJR, CR05, CR05SUB, CR10, CR10SUB, CR20, CR20SUB, CR10HT), first pipe size in text with unit IN or MM, first cable length, and the same family of choices for the second channel. The remaining positions cover power, analog and digital output, discrete outputs, language and default units. C-AT transducers are IP68 at 0.5, 1 and 2 MHz, while CR10HT is rated to 230 C.
Use cases for AT620 in Oman and the GCC
A pumping station with duty and standby delivery lines can be metered with one transmitter and two transducer pairs. A critical cooling-water header can be fitted with two paths for redundancy. Treated water leaving a plant can be cross-checked against what the network receives. Industrial effluent lines, district cooling circuits and desalination feed pipes are comparable cases where the combined path averaging helps with non-ideal straight runs.
Installation notes
Each path uses its own matched pair of transducers mounted with the strap-and-fixture method. Assume about 10 diameters of straight pipe upstream and 5 downstream; the datasheet notes final installation accuracy depends on fluid, temperature range, pipe centricity and other factors. When combining two paths on one pipe, mount them in the geometry that best averages out profile distortion. Use PanaViewPlus software to log and inspect each channel, and record the transducer spacing, couplant type and pipe wall data in the commissioning file so that a replacement transmitter can be configured identically if the unit is ever swapped.
Planning tip: when two pipes share one AT620, the two cable runs can differ in length (the first and second cable codes are chosen independently), and each channel can use a different transducer type and pipe size. That makes it practical to meter, for instance, a 6 in line with 2 MHz transducers and a 16 in line with 1 MHz transducers from the same wall-mounted unit. Keep in mind that each channel still needs its own straight run and its own pipe data entered correctly; the accuracy statement applies per path and assumes a fully developed symmetrical profile. Redundancy also has a diagnostic benefit, because disagreement between the two paths on one pipe is an early warning of coupling loss, fouling, or a flow profile that no longer matches the assumed model.
Supplier note and ordering help
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; we can help you decide whether one channel or two is more economical.
Documents and quotation
A manufacturer datasheet for AT620 is available here. Send an RFQ with AT620, C1 or C2 system, pipe diameters, transducer codes, cable lengths, power and output choices, and quantity.
Other Models in the Panametrics Aquatrans Range
Seven Star LLC supplies models from the Panametrics Aquatrans range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Panametrics AquaTrans AT868 Water Ultrasonic Flow Transmitter | Ultrasonic Flowmeters | View details |
| Panametrics AquaTrans AT620 Two-Channel Clamp-On Flowmeter | Ultrasonic Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Panametrics AquaTrans AT620 Two-Channel Clamp-On Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics AquaTrans AT620 Two-Channel Clamp-On
Answers from our engineering team on installation, compatibility and integration.
01How is the AT620 different from the AT600?
The AT620 supports two channels, so one transmitter can run two paths on one pipe or one path on each of two pipes, while the AT600 has a single channel.
02Does AT620 provide redundancy?
In a dual-path single-pipe layout the second path keeps measuring if one signal path is interrupted or degraded.
03What pipe sizes does AT620 handle?
0.5 in to 300 in (15 mm to 7600 mm) for metals and most plastics, with 1 percent accuracy in applications of 2 in and larger.
04What communication does AT620 offer?
4-20 mA, frequency, pulse or alarm outputs, HART 7.5 and Modbus RS485, each isolated to 1500 VDC.
05Which approvals does the AT620 datasheet list?
The AT620 datasheet lists CE, UL and CSA certification for the transmitter, and general purpose rating for the transducers.