Brand:

Panametrics PanaFlow FLI GZ1 Insertion Ultrasonic Gas Flowmeter

Description

PanaFlow FLI GZ1 single-path gas meter system

Panametrics sells the PanaFlow FLI as a family of insertion-type ultrasonic gas flowmeters, and GZ1 is the model code of the one-path system (GZ2 is the two-path version). The meter is delivered either as a flowcell, meaning a flanged spool with the transducer nozzles already built in, or as a nozzle-only kit that is welded onto an existing line. It is designed for fuel gas, natural gas, vent and waste gas, shale and coal-seam gas, vapor recovery, biogas, flare gas and even steam. What distinguishes the GZ1 from the cast ZxG meters is its retractable transducer mechanism: the transducers can be withdrawn and reinserted while the process stays on line, around the clock.

GZ1 feature summary

  • Measuring range of 0 to 100 m/s (328 ft/s), set finally by the transmitter selected.
  • Field-proven T5 and T5Max titanium transducers tolerant of wet and corrosive gas; Monel, Hastelloy or SS316 available.
  • Compact insertion mechanism with packing and o-ring seal, usable 24 hours a day, 7 days a week.
  • Meter sizes 3 in to 24 in (80 mm to 600 mm) as standard.
  • Diagnostics including sound speed and signal strength; percent methane for biogas and molecular weight for fuel or waste gas, depending on the transmitter.
  • Works with XGM868i, XGS868i or XGS868 transmitters.

GZ1 technical data

Item PanaFlow FLI GZ1
Flow accuracy, flowcell 1.5% of reading standard calibration; 1.0% enhanced calibration, velocity 5 ft/s and above
Accuracy, nozzle system 1.5% to 2.5% of reading
Low-flow sensitivity 0.02 m/s (0.075 ft/s) for 0.15 to 1.5 m/s
Repeatability 0.5% of reading
Straight run assumed About 20 diameters upstream and 5 downstream
Transducer temperature NT -55 to 150 C; HT -50 to 250 C; XT -50 to 300 C
Pressure MAOP 285 psig (18.63 bar); retraction at 50 psig (4.46 bar) or less
Insertion mechanism 1.5 in 150 lb flange or 1.5 in NPT, stainless steel; options super duplex, Hastelloy, Inconel
O-ring ratings FKM -54 to 204 C; Markez Z1321 -45 to 250 C; Markez Z1400 -15 to 335 C
Flowcell body Carbon steel or stainless steel, 150 lb flange, ASME B31.3 or PED, NACE MR0103
Hazardous area Explosion-proof Class I Div 1 Group CD (B on request); II 2G Ex d IIC T6 to T2 Gb, ATEX and IECEx

How GZ1 differs from other PanaFlow gas meters

Compared with the ZxG range, the FLI GZ1 is limited to a 150 lb flowcell and a maximum pressure of 285 psig, where the ZxG goes to 600 lb flanges. In return the GZ1 allows hot-tap style access to the transducers, supports process temperatures up to 300 C with extreme-temperature transducers, and can be supplied as a nozzle kit. Single-path accuracy of 1.5 percent matches the Z1G, and the two-path GZ2 improves on it in the same way that Z2G improves on Z1G.

Decoding the GZ1 order string

The one-path ordering string begins with GZ1 followed by body paths (1), size (03 to 24), 150 flange, material (CS or SS), schedule (STD for carbon steel, 40S for stainless), design (A for B31.3 with NACE, P for PED), paint (A none, B primer to 400 C, C epoxy to 230 C), documentation (A to E, from none up to PMI with 3.2 certificates), hazardous-area code (0 to 5 plus national marks such as Taiwan TS, Russia EAC, Korea KCS, China NEPSI, India CCOE, South Africa), transducer temperature class (NT, HT, XT or NTMAX), holder (TSS, F1SS, F1SD, F1IN, F1HC), o-ring (F, M1, M2), isolation valve (for example VTSST1 up to VF1HCT2), preamplifier gain (00, 02, 10, 20 or 40), junction box, and calibration (CAL for 1.5 percent or CALE for 1 percent).

Use in Oman and the GCC

Insertion meters fit refinery fuel gas headers, wellsite gas gathering, landfill and digester gas at municipal plants, and steam lines on utility sites. Because transducers can be pulled out under pressure up to 50 psig, a maintenance crew does not need to shut a header, a major benefit on lines feeding continuous process units. Isolation valves with ratings up to 425 C are listed for NPT carbon steel or stainless steel versions.

Several design decisions are worth settling before an RFQ goes out for GZ1. First, pick the transducer temperature class from the real gas temperature including upset conditions: the NT and NTMAX types stop at 150 C, while HT and XT versions are needed for hot vent or steam service. Second, match the isolation valve to both temperature and pressure rating; the datasheet lists stainless NPT valves rated -50 to 260 C or to 425 C, and 150 lb flanged valves in stainless, carbon steel, super duplex, Inconel and Hastelloy C. Third, decide the documentation package, because material certificates to EN 10204 3.1 or 3.2 and PMI add traceability for regulated plants. Finally remember that the stated 285 psig maximum and the 50 psig retraction limit mean live withdrawal is for low-pressure gas systems such as flares and fuel headers rather than high-pressure transmission.

Installing GZ1 and keeping it running

A flowcell GZ1 is bolted between flanges. Nozzle-only systems use 1.5 in 150 lb long-weld-neck nozzles on angle-cut 3 in to 24 in pipes in tilted-diameter configuration, and two nozzle systems are ordered if two paths are needed. Choose the o-ring material to suit the gas: FKM for general duty, Markez for higher temperatures or aggressive chemistry. Check the preamplifier gain and cable runs when using the remote XGM868i or XGS868i transmitter.

Supplier note

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Spare transducers, preamplifiers and holders can be quoted on request.

Documents and quotation

The manufacturer datasheet for GZ1 is provided. In your RFQ list GZ1, size, flowcell or nozzle, material, hazardous-area code, transmitter model and quantity.

Other Models in the Panametrics Panaflow Gas Range

Seven Star LLC supplies models from the Panametrics Panaflow Gas range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics PanaFlow PF8M-Z2G Two-Path Ultrasonic Gas FlowmeterUltrasonic FlowmetersView details
Panametrics PanaFlow FLI GZ1 Insertion Ultrasonic Gas FlowmeterUltrasonic FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Panametrics PanaFlow FLI GZ1 Insertion Ultrasonic Gas Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics PanaFlow FLI GZ1 Insertion Ultrasonic

Answers from our engineering team on installation, compatibility and integration.

01What does GZ1 mean in PanaFlow FLI?
GZ1 is the model code for the one-path PanaFlow FLI meter system; GZ2 is the two-path system.
02What maximum pressure applies to PanaFlow FLI GZ1?
The maximum allowable operating pressure is 285 psig (18.63 bar), and transducer retraction is allowed at 50 psig or less.
03Which transmitters can run with the GZ1?
The datasheet lists the XGM868i, XGS868i and XGS868 transmitters.
04What temperature classes of transducer exist for GZ1?
Normal, minus 55 to 150 C; high, minus 50 to 250 C; extreme, minus 50 to 300 C, all titanium T5 types.
05Can GZ1 be fitted to an existing pipe without a spool?
Yes. A nozzle-only design uses 1.5 in 150 lb nozzles on angle-cut 3 in to 24 in pipes, with accuracy of 1.5 to 2.5 percent.