PanaFlow LZ: a wetted spool-piece ultrasonic meter for liquids

Where PanaFlow LC clamps to an existing pipe, the Panametrics PanaFlow LZ arrives as a complete flanged meter body with transducers already installed, welded and factory tested. It is a one- or two-path wetted ultrasonic flowmeter built on the XMT1000 electronics platform, intended for hydrocarbon liquids, crude oils, fuel oils, internal allocation metering, loading and unloading, pipeline metering, blending, solvents, chemicals, weak acid solutions and water, cooling water and wastewater. There is nothing in the flow path that can clog and nothing that moves, so the PanaFlow LZ needs no filters, strainers or periodic calibration according to the datasheet.

PanaFlow LZ main benefits

  • Accuracy of 0.5% of reading for velocities above 2 ft/s (0.6 m/s) up to 40 ft/s (12.2 m/s), resolution of 2 mm/s.
  • Repeatability 0.3% of reading typical; bidirectional range of 0.1 to 40 ft/s (0.03 to 12.19 m/s).
  • No pressure drop and no obstruction, so a pump does not have to be oversized to carry the meter.
  • All-welded construction with explosion-proof, field-replaceable transducers and no o-ring leak paths.
  • Optional Bundle Waveguide Technology (BWT) transducers for wider temperature limits.
  • Optional SIL-certified configuration when ordered with the matching XMT1000.

PanaFlow LZ specification table

Item PanaFlow LZ
Paths and sizes 1 path: 2 in to 24 in (50 to 600 mm); 2 path: 3 in to 24 in (80 to 600 mm)
Body material Carbon steel (A106 Gr. B / A105) or stainless steel (316/316L)
Flange ratings ANSI 150, 300 or 600 RF slip-on, per ASME B16.5
Pipe schedule STD or XS for carbon steel; 40S or 80S for stainless steel
WT transducers -40 to 175 C (-40 to 347 F), 316L buffers
BWT transducers -40 to 100 C or -40 to 250 C (-40 to 482 F)
Carbon steel minimum -20 C when a carbon steel body is used
Local electronics limit Not recommended above 149 F (65 C)
Design codes ASME B31.3, NACE MR0175/MR0103; CRN or PED 2014/68/EU as chosen
Hazardous area Class I Div 1 Groups B, C, D; ATEX and IECEx Ex d IIC T6
Remote cables RG62, up to 1000 ft (300 m), ordered separately
Paint choices High-temperature primer to 400 C, epoxy to 230 C, or none for stainless

Reading the LZ part number string

The code follows LZ-B-C-D E F G H I-J-K L M-Z. Position B selects the paths (1 or 2), C the body size from 002 (2 in) through 024 (24 in), then schedule, flange rating, body material, design standard, paint, testing, electronics mounting (L1000 local XMT1000, L868I local XMT868i, or RM remote), the transducer and buffer system, the junction box and hazardous-area rating, and the calibration code. The datasheet example is LZ-2-008-AA2CA1-RM-1AX1-0, a dual-path 8 in carbon steel meter with remote electronics. Transducer codes 1 and 2 give WT wetted transducers with 316SS Panadapta buffers to 175 C, while codes 3 and 4 select BWT1 transducers with FWPA buffers rated to 100 C or 250 C.

LZ differences from the other PanaFlow liquid meters

Compared with PanaFlow LC the LZ is a wetted design: 0.5% accuracy over 2 to 40 ft/s instead of 1% over 1 ft/s and up, but restricted to 24 in as the largest size instead of 300 in, and fixed to a prepared meter body. Compared with Z3, the LZ is a pure liquid meter with one or two paths and a standard flanged spool. The LZ supports calibration points recorded 3 as found and 2 as left, with ISO 17025 and SIL options.

Where PanaFlow LZ is used

For terminals, loading arms, tank farms and pipeline stations in Oman and the GCC, the LZ offers an alternative to turbine or positive displacement meters that foul or wear. In utilities and water the same body handles cooling water circuits and treated wastewater. Chemical plants can specify stainless 316L bodies for solvents and weak acid solutions, while refineries often pick carbon steel bodies with NACE-compliant design.

Installation and commissioning of PanaFlow LZ

The meter body is a length of pipe with flanged ends and transducer ports rated to the pressure class, so installation is like fitting a spool. Local electronics are already wired to the transducers; with remote electronics the transducer cable must be run to the transmitter. Electronics ordered with the system are pre-programmed from the application data, so the meter is ready after the body is bolted in. Drawings 712-2122 to 712-2125 cover the general arrangements, for example 4 in to 24 in single-path, and 6 in to 24 in dual-path mid-radius designs.

Several points are worth checking before a purchase request is raised. The accuracy statement in the datasheet assumes a single-phase homogeneous liquid and a fully developed symmetrical profile, so a meter installed just after a pump discharge or a partly open valve may need extra straight run or flow conditioning. Pipe schedule matters too: carbon steel systems are offered in STD or XS wall, stainless systems in 40S or 80S, and the flange class must match the line rating because pressure capability follows the maximum allowable flange pressure at temperature. Paint choice should reflect the ambient and insulation arrangement, with the high-temperature primer rated to 400 C (750 F) and the epoxy to 230 C (450 F). Because remote cables are not included, add them to the same RFQ, using armored RG62 for ATEX or IECEx and non-armored RG62 in conduit for US and Canadian areas.

Servicing and spares

Transducers are field replaceable, and the buffer assemblies in the BWT option let them be swapped under operating conditions. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Documents and quotation

The manufacturer datasheet for PanaFlow LZ accompanies this page. Send an RFQ with the LZ order string, pipe size, flange class, body material, fluid and quantity for a quotation.

Other Models in the Panametrics Panaflow Liquid Range

Seven Star LLC supplies models from the Panametrics Panaflow Liquid range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics PanaFlow Z3 PF10-Z3 Three-Path Liquid FlowmeterUltrasonic FlowmetersView details
Panametrics PanaFlow LC Clamp-On Ultrasonic Liquid FlowmeterUltrasonic FlowmetersView details
Panametrics PanaFlow LZ Wetted Ultrasonic Liquid Flowmeter SystemUltrasonic FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Panametrics PanaFlow LZ Wetted Ultrasonic Liquid Flowmeter System Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics PanaFlow LZ Wetted Ultrasonic Liquid

Answers from our engineering team on installation, compatibility and integration.

01What accuracy does PanaFlow LZ achieve?
The datasheet states plus or minus 0.5 percent of reading for velocities above 2 ft/s up to 40 ft/s, with repeatability of 0.3 percent typical.
02What pipe sizes is the PanaFlow LZ offered in?
Single-path meters cover 2 in to 24 in and dual-path meters 3 in to 24 in, in carbon steel or 316/316L stainless steel.
03Can PanaFlow LZ use local electronics at high temperature?
Local electronics are not recommended above 149 F (65 C); remote mounting is the alternative.
04What temperature ranges do the LZ transducers cover?
WT transducers run -40 to 175 C and BWT transducers -40 to 100 C or -40 to 250 C, subject to the -20 C limit with a carbon steel body.
05How is PanaFlow LZ calibrated?
The order code selects three points as found and two points as left, optionally ISO 17025 and SIL variants.