Description
Panametrics AT868 overview
The Panametrics AquaTrans AT868 is a liquid flow ultrasonic transmitter designed specifically for water and wastewater applications in full pipes. It is a complete flow metering system for potable water, wastewater, sewage, discharge water, treated water, cooling and heating water and other liquids. The transmitter is a low-cost package that is installed at the process measurement point.
Inside, the all-digital AT868 has no moving parts and needs minimal maintenance. An onboard microprocessor uses the patented Correlation Transit-Time technology for long-term, drift-free operation, with automatic adjustment to changing fluid properties. Clamp-on transducers never touch the process fluid, so the meter suits lined pipes, while wetted transducers with Pan-Adapta plugs can be installed and removed without interrupting the process or emptying the pipe.
Key features of the AT868
- Economical, nonintrusive flow measurement.
- Simple setup with an internal six-button keypad.
- Suitable for a wide range of pipe sizes and materials, including lined pipes.
- Two-channel, two-path version available.
- Velocity, volumetric and totalized flow.
- Weatherproof Type 4X/IP66 epoxy-coated aluminum housing weighing about 2 lb (0.9 kg).
- Optional submersible IP67/68 transducers and 12 to 28 VDC supply.
Panametrics AquaTrans AT868 technical specifications
| Parameter | Value |
|---|---|
| Clamp-on pipe sizes | 0.5 to 300 in (12.7 mm to 7.6 m) and larger |
| Wetted pipe sizes | 1 in to 200 in (25.4 mm to 5 m) and larger |
| Pipe wall thickness | Up to 3 in (76.2 mm) |
| Accuracy (velocity) | 0.5 percent of reading with process calibration |
| Typical clamp-on accuracy | Pipe ID above 6 in: 1 to 2 percent; below 6 in: 2 to 5 percent |
| Typical wetted accuracy | Plus or minus 1 percent of reading |
| Repeatability | Plus or minus 0.1 to 0.3 percent of reading |
| Range (bidirectional) | -40 to 40 ft/s (-12.2 to 12.2 m/s); rangeability 400:1 |
| Power | 85 to 265 VAC, 50/60 Hz; optional 12 to 28 VDC; 20 W maximum |
| Operating temperature | 14 to 131 deg F (-10 to 55 deg C) |
| Standard outputs | One 0/4 to 20 mA output (600 ohm max) and one frequency/pulse/totalizer output per channel |
| Digital interface | RS232 standard; optional RS485 |
| Enclosure | Type 4X/IP66; 7.25 x 5.9 x 3.5 in (184 x 150 x 89 mm) |
| Clamp-on transducer temperature | -40 to 150 deg C standard; optional -200 to 400 deg C |
| Wetted transducers | -40 to 100 deg C, 0 to 3000 psig (207 bar); 1 in or 3/8 in NPTM |
Wetted transducers are stainless steel as standard, with titanium, Hastelloy, Monel, duplex, CPVC, PVDF and other materials available for Pan-Adapta plugs.
Typical applications in Oman and the GCC
In Oman and the GCC the AT868 suits municipal water transmission lines, treated effluent discharge, sewage rising mains flowing full, cooling water circuits and district cooling. Utilities that need to check a line without cutting the pipe can use clamp-on transducers for temporary or permanent flow measurement.
Selection and compatibility notes
Choose clamp-on for fastest installation or wetted for best accuracy. Confirm that the pipe runs full, state material and wall thickness, and choose one or two channels. For harsh outdoor sites ask for the submersible transducer option, and select between AC and DC supply.
The AT868 is built for full-pipe water service, so the first check is that the pipe stays full at the proposed measurement point. Siphons, vertical downward runs and open discharges can leave a partially filled pipe, which ultrasonic transit-time meters cannot measure correctly. A point near a low spot or after a pump is usually better.
The AT868 is one of the simpler meters in the Panametrics range, so it suits utilities that want a clear, low-cost water meter and do not need hazardous area housings. For those, consider the XMT868i instead.
When you request an AT868 quotation, include the pipe outside diameter, wall thickness, material and any lining, because these set the transducer choice and spacing. Mention also whether the readout will be local only or tied into a SCADA system, so the correct output and digital interface options are quoted.
Installation and commissioning
Pick a section with straight run of roughly 10 diameters upstream and 5 downstream, flow above 1 ft/s. Fit the clamp-on transducers with the supplied fixtures or install wetted transducers in a flowcell, hot tap or cold tap, then wire power, outputs and transducer cables (RG62 AU coaxial, up to 1000 ft). Program through the internal keypad.
Maintenance and service life
There are few maintenance needs. Check transducer cable glands and fixtures, and review diagnostics when readings appear unstable. The PanaViewPlus PC interface software can be used over RS232.
Related products and ordering notes
For larger or hazardous liquid duties see the XMT868i and DF868. Include pipe details, fluid, power supply, channels and transducer type in the RFQ for the AT868. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about the AT868
- What is the AT868 designed for? It is a liquid flow ultrasonic transmitter designed specifically for water and wastewater applications in full pipes.
- Can the AT868 be used on lined pipes? Yes. The datasheet lists suitability for lined pipes when used with clamp-on transducers.
- What outputs does the AT868 have? One 0/4 to 20 mA output and one frequency, pulse rate or totalizer output per channel, plus RS232 as standard.
Documents and quotation
A manufacturer datasheet for the AT868 is available from Seven Star LLC on request and is attached to this listing where provided. To receive a quotation, send the RFQ with the part number AT868, the quantity required and your delivery location, together with any hazardous area, range or configuration details from your project specification.
Ordering Checklist for Panametrics AquaTrans AT868
Before you request a quotation for the Panametrics AquaTrans AT868, confirm the complete order code shown on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If you are upgrading rather than replacing like for like, tell us the existing make and model so the mounting, wiring and connection details can be checked against the flowmeters you already run. For multi-unit orders, list the quantity per site and the required delivery location in Oman or the wider GCC, so packing, documentation and lead time can be confirmed in one quotation instead of several follow-up emails.
Datasheets & Documents
- Datasheet Panametrics AquaTrans AT868 Water Ultrasonic Flow Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics AquaTrans AT868 Water Ultrasonic Flow
Answers from our engineering team on installation, compatibility and integration.
01What is the AT868 designed for?
It is a liquid flow ultrasonic transmitter designed specifically for water and wastewater applications in full pipes.
02Can the AT868 be used on lined pipes?
Yes. The datasheet lists suitability for lined pipes when used with clamp-on transducers.
03What outputs does the AT868 have?
One 0/4 to 20 mA output and one frequency, pulse rate or totalizer output per channel, plus RS232 as standard.
04What power supply does the AT868 use?
85 to 265 VAC at 50/60 Hz as standard, or 12 to 28 VDC optionally, at 20 W maximum.
05Is a two-channel AT868 available?
Yes. An optional second channel measures two pipes or averages two paths on one pipe.