- Automation & ControlView all 2,856 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Panametrics
Panametrics DigitalFlow DF868 Liquid Ultrasonic Flowmeter
Description
Panametrics DF868 overview
The Panametrics DigitalFlow DF868 is a full-featured, fixed-installation liquid flowmeter designed for flow metering and energy measurement. Its patented Correlation Transit-Time digital signal processing gives drift-free measurements in ultraclean liquids and in most dirty liquids, including fluids with gas bubbles and entrained solids that earlier needed Doppler-type meters.
With clamp-on transducers the DF868 measures flow through metal, plastic or even concrete-lined pipe without penetrating the wall. A range of clamping fixtures covers different pipe sizes and attachment methods, including a special small-pipe fixture with miniaturized transducers for 0.5 to 2 in (15 to 50 mm) lines. For maximum accuracy, obstructionless wetted transducers can be used, giving transit-time accuracy better than 1 percent in most applications. Every DF868 has two independent graphic LCDs and a built-in 43,000 point datalogger.
Key features of the DF868
- Clamp-on or wetted transducer measurement, 400 to 1 turndown.
- Two independent, user-programmable graphic LCDs.
- Built-in 43,000 point datalogger.
- Energy measurement software in every meter, with RTD or analog input boards, for water and water/glycol systems from -20 to 210 deg C.
- Automatic Tracking Window for changing sound speed.
- Up to 12 isolated 4 to 20 mA outputs, six alarm relays and 12 frequency/totalizer outputs.
- Optional two-channel version and hazardous area certifications.
Panametrics DigitalFlow DF868 technical specifications
| Parameter | Value |
|---|---|
| Fluid types | Acoustically conductive fluids, including liquids with entrained solids or gas bubbles |
| Clamp-on pipe sizes | 0.5 to 300 in (12.7 mm to 7.6 m) and larger |
| Wetted pipe sizes | 1 to 200 in (25.4 mm to 5 m) and larger |
| Pipe wall thickness | Up to 3 in (76.2 mm) |
| Accuracy (velocity) | Plus or minus 0.5 percent of reading with process calibration |
| Typical clamp-on accuracy | Above 6 in: 1 to 2 percent; below 6 in: 2 to 5 percent |
| Typical wetted accuracy | Plus or minus 1 percent of reading |
| Repeatability | Plus or minus 0.1 to 0.3 percent of reading |
| Range (bidirectional) | -40 to 40 ft/s (-12.2 to 12.2 m/s); rangeability 400:1 |
| Power | 100 to 130 VAC or 200 to 265 VAC, 50/60 Hz; optional 12 to 28 VDC; 20 W maximum |
| Standard outputs | Two isolated 0/4 to 20 mA, 550 ohm maximum, NAMUR NE043 |
| Operating temperature | -4 to 131 deg F (-20 to 55 deg C) |
| Enclosure | Epoxy-coated aluminum Type 4X/IP66 Class I Division 2 Groups A, B, C, D; options stainless, fiberglass, explosion-proof, flameproof |
| Size and weight | 14.24 x 11.4 x 5.1 in (362 x 290 x 130 mm); 11 lb (5 kg) |
| Clamp-on transducer temperature | -40 to 150 deg C standard; optional -200 to 400 deg C |
| Keypad and display | 39-key membrane keypad; two 64 x 128 pixel backlit LCDs |
Six additional slots hold analog output, analog input, RTD input, totalizer or frequency output and relay boards in any combination, according to the manufacturer.
Typical applications in Oman and the GCC
The listed fluids are water and wastewater, hot and chilled water, water and glycol solutions, refined hydrocarbons, petroleum products, crude oil, lubricating oils, diesel and fuel oils, solvents and chemicals. In the GCC the DF868 is used for hydrocarbon transfer metering, cooling water and chilled water energy measurement, and process liquid monitoring on existing pipes without shutdown.
Selection and compatibility notes
Choose clamp-on or wetted transducers by accuracy needs and whether the pipe can be opened. Specify pipe data, fluid and temperature, the number of channels and the I/O boards. For BTU or energy metering, add RTD or analog temperature input boards. Compare with the XMT868i, which has a hazardous-area rated field transmitter housing, if you need that style.
The DF868 is a good fit when you need one meter that can be used on a temporary basis and later made permanent. A clamp-on setup can be applied to an existing line for a survey, and the same electronics can later be paired with wetted transducers if tighter accuracy is needed. The two displays let operators view flow numbers and a graph or waveform at the same time, which helps during commissioning.
State the fluid and temperature clearly in the RFQ. Sound speed, pipe wall condition and lining all affect the choice of transducer, and the more complete the data, the more accurately the correct transducer set can be quoted.
Installation and commissioning
Choose a measurement point with a fully developed flow profile, typically 10 diameters upstream and 5 downstream, and flow above 1 ft/s (0.3 m/s). Fit the clamping fixture using the ruled slide track to set transducer spacing, apply couplant, enter pipe parameters and verify signal strength on the diagnostic display.
Maintenance and service life
The meter is all digital, with no moving parts to wear out or orifices to clog. Routine checks cover cable condition, fixture tightness and signal diagnostics. Use the datalogger to review flow history.
Related products and ordering notes
Related Panametrics liquid flow items are the XMT868i, AT868 and PanaFlow HT. For a DF868 RFQ please list pipe, liquid, temperature, transducer type, channel count, I/O and area classification. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about the DF868
- What does the DF868 measure? It measures liquid flow and energy flow using ultrasonic correlation transit-time technology, with clamp-on or wetted transducers.
- Can the DF868 work on dirty liquids? Yes. The manufacturer states it handles most dirty liquids including those with gas bubbles and entrained solids that previously needed Doppler meters.
- Does the DF868 have a datalogger? Yes. It has a built-in 43,000 point datalogger and two independent graphic displays.
Documents and quotation
A manufacturer datasheet for the DF868 is available from Seven Star LLC on request and is attached to this listing where provided. To receive a quotation, send the RFQ with the part number DF868, the quantity required and your delivery location, together with any hazardous area, range or configuration details from your project specification.
Other Models in the Panametrics Digitalflow Range
Seven Star LLC supplies models from the Panametrics Digitalflow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Panametrics DigitalFlow XMT868i Liquid Ultrasonic Flow Transmitter | Ultrasonic Flowmeters | View details |
| Panametrics DigitalFlow XGS868i Steam Ultrasonic Flow Transmitter | Ultrasonic Flowmeters | View details |
| Panametrics DigitalFlow GC868 Clamp-On Gas Ultrasonic Flowmeter | Ultrasonic Flowmeters | View details |
| Panametrics DigitalFlow DF868 Liquid Ultrasonic Flowmeter | Ultrasonic Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Panametrics DigitalFlow DF868 Liquid Ultrasonic Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics DigitalFlow DF868 Liquid Ultrasonic
Answers from our engineering team on installation, compatibility and integration.
01What does the DF868 measure?
It measures liquid flow and energy flow using ultrasonic correlation transit-time technology, with clamp-on or wetted transducers.
02Can the DF868 work on dirty liquids?
Yes. The manufacturer states it handles most dirty liquids including those with gas bubbles and entrained solids that previously needed Doppler meters.
03Does the DF868 have a datalogger?
Yes. It has a built-in 43,000 point datalogger and two independent graphic displays.
04Can the DF868 measure energy?
Yes. Energy measurement software is included, with optional RTD or analog input boards, for water and water/glycol systems.
05What turndown does the DF868 have?
Overall rangeability is 400:1 across a bidirectional range of -40 to 40 ft/s.


















Reviews
There are no reviews yet.