Brand:

Viking Pump L8124A 135 GPM Cast Iron Mag Drive Gear Pump

Description

Overview

When a plant needs about 135 GPM (30 m3/h) of a hazardous or hard-to-seal liquid and cannot accept a leaking shaft seal, Viking Pump L8124A is the cast iron magnetic drive gear pump that the Viking catalog places in that slot. It turns at 640 rpm, has 2 inch NPT ports and weighs 280 lb (127 kg), so it is a substantial machine that still fits on the same footprint as the equivalent Universal Product Line pump. Seven Star LLC is an independent supplier serving Oman and the GCC.

Quick facts before the detail

  • Flow: 135 GPM (30 m3/h) at 640 rpm on medium viscosity liquid.
  • Ports: 2 inch (50 mm) tapped NPT, revolvable in 90 degree steps.
  • Pressure: 550 PSIG hydrostatic, 200 PSIG maximum discharge.
  • Temperature: 225 F (105 C) standard; 500 F (260 C) with high temperature construction.
  • Weight: about 280 lb (127 kg) with relief valve, without drive.

Specification table for Viking Pump L8124A

Parameter Value
Model Viking Pump L8124A, series 8124A, sealless mag drive, catalog section 1403
Port size 2 inch (50 mm), tapped for NPT
Nominal capacity 135 GPM (30 m3/h) at 640 rpm
Casing, head and bracket Cast iron, ASTM A48 Class 35B
Rotor Cast iron ASTM A48 Class 35B; steel ASTM A148 Grade 80-50 optional
Rotor shaft and idler pin Hardened steel, ASTM A108 Grade 1045
Bushings Carbon graphite standard; hardened cast iron or silicon carbide optional
Canister 316L stainless steel
Magnets Neodymium iron boron standard; samarium cobalt above 225 F (105 C)
Maximum hydrostatic pressure 550 PSIG (38 bar)
Maximum discharge pressure 200 PSIG (14 bar)
Temperature, standard pump 225 F (105 C)
Temperature, high temperature construction 500 F (260 C)
Viscosity range, series 28 to 250,000 SSU (1 to 55,000 cSt)
Shipping weight with valve 280 lb (127 kg)

Where Viking Pump L8124A sits in the 8124A range

The 8124A line is made of ten models running from H to QS, and the Viking Pump L8124A is the largest of the models that keep standard threaded 2 inch ports. Directly beside it, the LQ8124A has the same 135 GPM rating and 640 rpm but moves to 2 1/2 inch flanged ports, a 300 PSIG hydrostatic rating and a weight of 290 lb. Above them the LL8124A reaches 170 GPM, the LS8124A reaches 200 GPM, and the Q8124A reaches 300 GPM. If your line is 2 inch threaded and you need the highest flow at the lower pressure class, the L is the model to choose. If you need flanges, move to LQ.

How the pump contains the liquid

A pair of magnet assemblies, one outside and one inside a 316L stainless canister, replace the stuffing box. The inner assembly rides on the rotor shaft, supported by a canister bushing and an idler bushing placed with a long spread to minimise shaft deflection. Cooling flow runs between shaft and bushing and back through a hollow idler pin. In the L size the circulation path follows the hollow shaft arrangement shown in the catalog for sizes H through LS, which is opposite to the route used in the Q and QS sizes.

Since the drive is sealless, the liquid never meets an elastomer face seal. Static O-rings at the joints do the sealing, and the standard O-ring material should be confirmed against your liquid before ordering.

Applications seen in the region

Typical duties include loading and unloading of isocyanates and polyols, adhesive resins, fatty acids and solvent transfer in chemical blending plants. In Oman and across the Gulf, similar liquids move through free zone chemical hubs and in the process units of refineries and petrochemical sites. Because the pump can run in both directions, one unit can both fill and empty a tank. Viscosities between 28 and 250,000 SSU are accepted, so the same pump may handle a thin solvent in one season and a heavier resin in another.

Commissioning checklist

  • Confirm the relief valve points towards the suction port and the valve spring setting is below the system pressure limit.
  • Check the coupling alignment and the gap between the outer magnet and the pump bracket.
  • Prime the casing so that the bushings are wet at the first start.
  • Open both isolating valves before starting; never run against a closed discharge.
  • Record motor amps and bearing carrier temperature at steady running.

Care and replacement parts

The bushings and thrust washers set the service life. Carbon graphite is standard, with silicon carbide and hardened cast iron available as options for abrasive duties. Keep a spare bushing and O-ring set and, if the process uses the optional temperature monitor port, log the reading each week. For the Viking Pump L8124A the catalog lists a tightening torque for the head fasteners, so use a torque wrench when reassembling.

Materials and why they matter

The casing, head and bracket are cast iron to ASTM A48 Class 35B, which gives good damping and low cost for non-corrosive liquids. The rotor is cast iron as standard and can be specified in steel to ASTM A148 Grade 80-50 when the liquid is viscous and the torque loads are high. The rotor shaft and idler pin are hardened steel to ASTM A108 Grade 1045, and the canister is 316L stainless steel, chosen because it is non-magnetic and resists most process liquids. If your liquid attacks cast iron, the Viking range offers separate stainless steel mag drive series, and this model is not the right choice.

Neodymium iron boron magnets are standard. They lose strength at higher temperature, which is why the catalog switches to samarium cobalt above 225 F (105 C). Do not guess at this point in the selection: tell us the maximum liquid temperature, including any steam-out or flushing step, so that the right magnet material is quoted.

Pump versus coupling load

A magnetic coupling has a torque limit, and viscous liquids at low temperature can exceed it when the pump starts cold. If the coupling slips, the pump stops pumping and the magnets can heat up. Size the drive from the coldest viscosity, warm the product if possible before starting, and avoid shock loads such as starting against a closed valve. The pump can be driven by a motor, a gear reducer or a belt arrangement, and the catalog describes the torque specification of the fasteners for each size group, so reassembly should follow it exactly.

Related items you may also need: Debem Boxer 100 Air-Operated Double Diaphragm Pump | KRACHT KF 0 Stainless Steel Process Gear Pump | Allweiler OptiFix Progressing Cavity Pump AEB 2E-MF and 1F-MF | All Viking Pump products.

Viking Pump L8124A ordering checklist

  • When the Viking Pump L8124A replaces an installed unit, check the existing nameplate against the code on this page before ordering.
  • Every enquiry for the Viking Pump L8124A is answered with a written confirmation of the code and expected lead time.
  • Use the attached datasheet to check the Viking Pump L8124A ratings, dimensions and connection details against your drawings.
  • We supply the Viking Pump L8124A as part of our positive displacement pumps range to plants in Oman and the GCC.
  • For critical duty, keeping one Viking Pump L8124A as a site spare shortens downtime after a failure.

Documents and quotation

The catalog section for the 8124A series is attached, including the model key, materials, the dimension tables for sizes H through LS and the operating limits. For a quotation on Viking Pump L8124A, send the quantity, the liquid and operating temperature, the preferred drive and the delivery point in Oman or the GCC.

Other Models in the Viking 8124a Range

Seven Star LLC supplies models from the Viking 8124a range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Viking Pump K8124A Sealless Mag Drive Internal Gear PumpPositive Displacement PumpsView details
Viking Pump L8124A 135 GPM Cast Iron Mag Drive Gear PumpPositive Displacement PumpsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Viking Pump L8124A 135 GPM Cast Iron Mag Drive Gear Pump Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.

Viking Pump company profile

Founded 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth
Headquarters Cedar Falls, Iowa, USA
Ownership A unit of IDEX Corporation since 1989
Core technology Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps
Typical liquids Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives
Standards API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot

Milestones

  • 1904: Jens Nielsen patents his internal gear pump design.
  • 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
  • 1989: Viking becomes part of IDEX Corporation.
  • 2011: Viking marks 100 years in Cedar Falls.
  • Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.

How a Viking internal gear pump works

An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.

Where Viking pumps are used in Oman and the GCC

In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.

Viking Pump models we list

Family Examples
General-purpose internal gear pumps KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A
Jacketed and heated pumps KK224C, Q224C, M224A, KK124E asphalt
Steel and stainless steel pumps L123C, QS4123C, RS4323A, KK127C, Q4127C
API 676 pumps LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA
Motor speed, external gear and mag drive pumps HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive
Special-duty pumps KK4924A ammonia, KK4624C abrasive, LVP41027 vane

Ordering Viking pumps: what we need

Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.

Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.

FAQ

Questions about the Viking Pump L8124A 135 GPM Cast Iron Mag Drive Gear

Answers from our engineering team on installation, compatibility and integration.

01What is the capacity of the Viking Pump L8124A?
The catalog rating is 135 GPM (30 m3/h) at 640 rpm on medium viscosity liquid, with 2 inch NPT ports and clockwise rotation.
02How does the L8124A differ from the LQ8124A?
Both are rated 135 GPM at 640 rpm, but the LQ has 2 1/2 inch flanged ports, a 300 PSIG hydrostatic rating and a weight of 290 lb, while the L has 2 inch NPT ports and 550 PSIG.
03What material is the L8124A canister made of?
The canister is 316L stainless steel, while the casing, head and bracket are cast iron to ASTM A48 Class 35B.
04Which liquids suit the L8124A?
It handles thin and thick liquids from 28 to 250,000 SSU, especially hazardous, difficult-to-seal liquids such as petrochemicals, isocyanates and polyols.
05How heavy is the L8124A?
The catalog shipping weight with relief valve is about 280 lb (127 kg), excluding the motor, coupling and base.