Viking Pump L123C Steel Gear Pump 135 GPM 2.5 in
Description
Overview
Viking Pump L123C is a packed, all-steel internal gear pump with 2.5 inch flanged ports and a nominal capacity of 135 GPM (31 m3/h) at 640 rpm. The 123C Series is positioned by the manufacturer for refinery and petrochemical applications and for extremely high temperatures, with a steel casing, head and bracket and the U-Plus bracket for sealing flexibility. Its packed gland is rated 450 F (230 C). Seven Star LLC is an independent supplier serving Oman and the GCC.
The 2.5 inch port is unusual
Most pumps in the range have ports of 1.5, 2, 3 or 4 inches. The L size is the one that uses 2.5 inch ports, which sits between the 2 inch KK and 3 inch LL. Many plants only discover this when piping drawings arrive, so confirm the size you need. The ProPort casing lists 2.5 inch Class 150 and Class 300 flanges for the L size, as well as DIN 65 options in the cast iron line, so check the flange class against your line specification.
Key data for Viking Pump L123C
| Parameter | Value |
|---|---|
| Model | Viking Pump L123C, steel externals, non-jacketed, packed |
| Port size | 2.5 inch flanged, 90 degree |
| Nominal rating | 135 GPM (31 m3/h) |
| Rated speed | 640 rpm |
| Maximum hydrostatic pressure | 400 PSIG (28 bar) |
| Maximum discharge pressure | 200 PSIG (14 bar) |
| Maximum temperature, standard pump | 450 F (230 C) |
| Approx. shipping weight with valve | 221 lb (100 kg) |
| Casing, head, bracket | Steel ASTM A216 Class WCB |
| Shaft | High strength steel ASTM A434 Type 4140 Grade BC |
| Bushings | Bronze ASTM B584 alloy C93700 |
| Packing | Braided PTFE |
| Relief valve body | Stainless steel (L, LL, LS sizes) |
| Series temperature range | minus 20 to 800 F (minus 30 to 425 C) |
Why choose packing
Braided PTFE packing is the standard seal in the 123C Series. It is adjustable in service, it tolerates solids and crystallising liquids, and the catalog lists packed gland service as good up to 2,000,000 SSU, equal to the best cartridge seals. For heavy fuel oil, crude residue and waxes that foul a mechanical seal, a packed Viking Pump L123C is a proven choice. The cost is a controlled drip at the gland that must be piped or managed, so plants with zero-leak policies should consider the L4123C with a mechanical seal instead.
Placing the L123C in the 123C range
Below it the KK123C is 100 GPM at 780 rpm with 2 inch ports and 132 lb. Above it the LL123C is 140 GPM at 520 rpm through 3 inch ports and 234 lb, and the LS123C is 200 GPM at 640 rpm and 250 lb. The L4123C has the same capacity but a mechanical seal and a 350 F limit. The Viking Pump L123C is the only 2.5 inch steel pump in this line, with the 135 GPM rating that suits mid-sized transfer lines.
Typical applications in Oman and the GCC
Hot lube oil and fuel oil transfer, asphalt and residue lines in refineries, thermal oil circuits and polymer or resin transfer are typical duties. Steel externals are specified when plant standards demand cast steel pressure containing parts. Marine fuel bunkering and power station heavy fuel oil skids also use pumps of this construction.
Selection notes
- NPSH required for the L size is 1.6 ft at 100 rpm, 3.8 ft at 350 rpm, 5.0 ft at 420 rpm, 7.3 ft at 520 rpm and 10.8 ft at 640 rpm for viscosities up to 750 SSU.
- Steel fitted construction is recommended above 25,000 SSU (5,500 cSt) for the L size.
- Above 225 F (105 C) request extra clearances and high-temperature bushings.
- Heat exchanger fluids and hot oil may need a pump slower than rated, which can mean a larger size.
Installation of the Viking Pump L123C
Mount on a rigid baseplate, using a spacer coupling so cartridge seals can be added later if the duty changes. Pipe with expansion loops to prevent pipe loads on the flanges, since hot lines move. Pack the gland gently at first, run the pump, and tighten only until the drip is controlled. Confirm the relief valve return piping before starting.
Maintenance
Check gland leakage each shift in the first week, replace rings when adjustment cannot control the weep, and grease bearings by the service manual. Bronze bushings are the main wear parts, and rotor end clearance can be reset by rotating the bearing housing.
Specifying a hot service pump
When the Viking Pump L123C is used on hot service, send the maximum operating temperature, not just the normal temperature. Upset conditions matter: the catalog allows higher temperatures with special construction, but the standard bushings, clearances and gaskets are chosen for the stated limit. Include whether the heat-up is slow or rapid, since steel casings tolerate thermal gradients better than cast iron but still need careful warm-up. Mention whether you want the relief valve in a stainless body, which is the standard for L size, or a return-to-tank valve. A complete description allows the factory to confirm the clearance set and elastomers, and avoids delays after the order.
Bearing, bushing and clearance details of the Viking Pump L123C
Inside the Viking Pump L123C the rotor turns on a shaft supported by a bracket bushing and a bronze idler bushing, with axial thrust taken by a double row ball bearing or by tapered roller bearings. The bronze bushings are standard for packed pumps, whereas the mechanical seal L4123C uses carbon graphite for dry running tolerance. For clean lubricating liquids the bronze is an excellent compromise between cost and life. For thin or non-lubricating liquids below 100 SSU, the catalog advises carbon graphite bushings and a slower pump speed. For abrasive services, hardened or coated bushings and idler pins are listed as options, along with a hardened shaft and abrasive-resistant seals.
Rotor end clearance can be adjusted by rotating the threaded bearing housing. This helps maintain capacity as parts wear, and it lets the factory set a larger clearance when ordering a pump for viscous or hot liquid. The catalog also lists steel fitted construction, in which the rotor and idler are steel instead of cast iron, as the recommendation for viscosities above 25,000 SSU on the L size.
What the manufacturer recommends for hot service
Above 225 F the catalog recommends additional clearances, high temperature elastomers and bushings chosen for the temperature. PTFE is good to 450 F, FKM to 350 F and Buna to 225 F, so the packing and any gaskets should match your highest expected temperature. Beyond 450 F, special materials and sealing arrangements are required, and the factory should be contacted.
Related items you may also need: Verder VA25 Air-Operated Double Diaphragm Pump | Alfa Laval OptiLobe Hygienic Rotary Lobe Pump | KRACHT KP 1/4 A10A K0A 4NL1 High-Pressure Gear Pump | All Viking Pump products.
Checklist before ordering the Viking Pump L123C
- Before ordering the Viking Pump L123C, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
- Our team confirms the Viking Pump L123C code and lead time in writing before any order is placed.
Documents and quotation
The catalog section for the 123C and related series is attached. To request a quotation for Viking Pump L123C, send the RFQ with part number Viking Pump L123C, quantity, liquid and temperature data, and delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Viking Pump L123C Steel Gear Pump 135 GPM 2.5 in Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Viking Pump is a global leader in positive displacement pumping solutions, building internal and external gear pumps at its base in Cedar Falls, Iowa, as an IDEX company. Its range includes the 1124C Series internal gear pumps with U-Plus bracket design and O-Pro seal technology, GB-425 Series external gear pumps for pipeline injection, RTPg tanker pumps, and hygienic rotary lobe and circumferential piston pumps. These pumps move viscous and problematic liquids across industrial, energy, hygienic and transport applications, from lubrication, fuel transfer and chemical processing to asphalt and food-grade duty. Seven Star LLC is an independent supplier serving Oman and the GCC, helping buyers specify Viking Pump models matched to their liquid, flow rate and sealing needs for dependable uptime.
FAQ
Questions about the Viking Pump L123C Steel Gear Pump 135 GPM 2.5 in
Answers from our engineering team on installation, compatibility and integration.
01What capacity does the Viking Pump L123C have?
The catalog lists a nominal 135 GPM (31 m3/h) at 640 rpm through 2.5 inch ports, with 200 PSIG maximum discharge pressure.
02What is the casing material of the L123C?
Casing, head and bracket are steel to ASTM A216 Class WCB, the standard for the steel externals line.
03Is the L123C packed or sealed?
It is supplied with braided PTFE packing. The mechanical seal version has the code L4123C and a 350 F rating.
04What temperature can the L123C handle?
The standard packed pump is recommended up to 450 F (230 C), with extra clearances above 225 F (105 C).
05How heavy is the L123C?
The approximate shipping weight with the valve is 221 lb (100 kg).