Viking Pump H124C Cast Iron Internal Gear Pump 15 GPM

Description

Overview

The Viking Pump H124C is the smallest threaded pump of the cast iron 124C family from Viking Pump, an internal gear positive displacement pump for oils, resins, adhesives, fuels, inks and many other viscous liquids. Its 1 1/2 inch NPT ports, nominal rating of 15 gallons per minute at 1750 rpm and sturdy one-piece bracket make it a typical transfer, lube and burner-supply pump for skids and workshops. Because it is an internal gear design with only two moving parts in the pumping chamber, it delivers a steady, low-pulsation flow that rises and falls with speed rather than with pressure. Seven Star LLC is an independent supplier serving Oman and the GCC.

How the Viking Pump H124C moves liquid

A rotor with external teeth turns inside the casing, and a smaller idler gear rides on a fixed pin and meshes with the rotor on the inside of a crescent. As the teeth come out of mesh, the chambers open and draw fluid in through the suction port. The crescent separates inlet from outlet while fluid is carried in the tooth spaces, and the teeth mesh again at the discharge side to push the liquid out. There are no valves, no reciprocating parts and very few wearing surfaces, which is why the pump handles thick liquids that would starve a centrifugal pump and can keep working with viscosity from 28 to 2,000,000 SSU for the 124C series.

Rating and specification of Viking Pump H124C

Item Catalog value
Series 124C, cast iron, non-jacketed, U-Plus bracket
Nominal rating 15 GPM (3.5 m3/h) at 1750 rpm, liquids of 100 SSU and below
Standard port size 1 1/2 inch NPT
Maximum discharge pressure 200 PSIG (14 bar)
Maximum hydrostatic pressure 400 PSIG (28 bar)
Maximum recommended temperature 450 degrees F (230 degrees C)
Series temperature range minus 60 to plus 450 degrees F
Viscosity range of series 28 to 2,000,000 SSU (0.1 to 440,000 cSt)
Casing, head, bracket Cast iron, ASTM A48 Class 35B
Idler pin Hardened steel, ASTM A108 grade 1045 (4124C series)
Approximate shipping weight with valve 38.62 lb (17.5 kg)

How Viking Pump H124C differs from other 124C models

Inside the 124C range the first letters set the size. The H model sits above the G size, which is only 1 inch and 8 GPM, and below the HL, which has the same 1 1/2 inch ports but 30 GPM and 7 m3/h at the same 1750 rpm. Larger models slow the shaft to keep the tooth speed in check: the AK runs at 1450 rpm for 65 GPM, the K at 780 rpm for 80 GPM and the L at 640 rpm for 135 GPM. The Viking Pump H124C stays at 1750 rpm, so it can be driven directly by a four-pole motor, while the H1124C sibling with O-Pro seal is rated 8 GPM at 1000 rpm. These differences let buyers match flow and speed precisely.

Where the Viking Pump H124C serves in Oman and the GCC

Small internal gear pumps are fitted on lube oil skids, fuel transfer sets, burner pump stations, resin and adhesive dosing lines, paint and ink circuits and diesel generator day tank systems. In Oman and elsewhere in the GCC they are specified for maintenance workshops and small process plants where the liquid is too thick for a centrifugal pump but flow is modest. The cast iron body suits non-corrosive liquids, and the temperature rating of 450 degrees F allows hot oils and heated asphalt-type products with suitable options.

Installation practice

Mount the pump on a rigid base with the driver aligned through a flexible or spacer coupling, and size the suction line generously with short runs and few bends, since viscous liquids cause large suction losses. Provide a relief valve in the discharge, either integral on the head or in the pipe, because positive displacement pumps cannot be dead-headed. The catalog describes port location options, with ports at 90 degrees as standard and an opposite-port option for the larger sizes. Check rotation before filling the line and prime the pump with some liquid for first start-up.

Sealing options

The U-Plus bracket of the C series accepts packing, single component seals, lip seals, cartridge seals and the O-Pro barrier seal, which gives the buyer a wide choice according to the liquid, pressure and emission rules. The code in the model number tells which seal is fitted: a plain code means packing, a 4 means a mechanical seal and a 1 indicates an O-Pro seal. Confirm the seal choice with the liquid before ordering, because chemical compatibility decides the elastomer.

Maintenance

Inspect the packing or seal for leakage, check the bushings for wear during scheduled stops and replace the idler pin when it shows scoring. Keep records of flow and motor current: a gradual drop in flow at constant speed points to internal wear, and an increase in current points to a blocked strainer or a viscosity change. Use a suction strainer to protect the teeth from solids.

Ordering notes

When requesting Viking Pump H124C, state the liquid, temperature, viscosity, required flow and the seal preference. Mention whether you need a relief valve, a base plate or a motor, as they affect the quotation.

Selecting drive and relief protection for a small gear pump

A pump of this size is easily driven by a standard four-pole motor, but the motor power depends on the liquid. The catalog graphs show that viscous liquids need much more torque at the same speed, so check the starting torque when pumping cold oil, and consider a heated line or a soft starter. The relief valve should open before the discharge reaches the casing limit and should return liquid to the suction side of the pump or to the tank. Mark the direction arrow on the base so that wiring changes do not cause the pump to run backward.

Related items you may also need: Danfoss 180B3010 APP 10.2 Seawater High-Pressure Pump | KRACHT KP 1/4 F10A K0A 4NL1 High-Pressure Gear Pump | Danfoss 180B0040 PAH 63 High-Flow Water Pump | All Viking Pump products.

Documents and quotation

The catalog section covering the 124C series is attached to this page, with operating ranges, material lists, specifications and dimensions. Please send your RFQ with Viking Pump H124C, the quantity and your delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Viking Pump H124C Cast Iron Internal Gear Pump 15 GPM Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.

Viking Pump company profile

Founded 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth
Headquarters Cedar Falls, Iowa, USA
Ownership A unit of IDEX Corporation since 1989
Core technology Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps
Typical liquids Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives
Standards API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot

Milestones

  • 1904: Jens Nielsen patents his internal gear pump design.
  • 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
  • 1989: Viking becomes part of IDEX Corporation.
  • 2011: Viking marks 100 years in Cedar Falls.
  • Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.

How a Viking internal gear pump works

An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.

Where Viking pumps are used in Oman and the GCC

In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.

Viking Pump models we list

Family Examples
General-purpose internal gear pumps KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A
Jacketed and heated pumps KK224C, Q224C, M224A, KK124E asphalt
Steel and stainless steel pumps L123C, QS4123C, RS4323A, KK127C, Q4127C
API 676 pumps LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA
Motor speed, external gear and mag drive pumps HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive
Special-duty pumps KK4924A ammonia, KK4624C abrasive, LVP41027 vane

Ordering Viking pumps: what we need

Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.

Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.

FAQ

Questions about the Viking Pump H124C Cast Iron Internal Gear Pump 15

Answers from our engineering team on installation, compatibility and integration.

01What flow does the Viking Pump H124C deliver?
The catalog gives a nominal rating of 15 GPM, 3.5 m3/h, at 1750 rpm for liquids of 100 SSU and below.
02What port size does the H124C have?
The standard port size is 1 1/2 inch NPT, with optional opposite port arrangements for H to Q sizes in the 124C series.
03What is the maximum temperature of the H124C?
The maximum recommended temperature for the standard pump is 450 degrees F, or 230 degrees C.
04What is the H124C made of?
The casing, head and bracket are cast iron to ASTM A48 Class 35B, with options for bushings, shaft, rotor and idler materials.
05How does the H124C differ from the HL124C?
Both have 1 1/2 inch ports and run at 1750 rpm, but the H is rated 15 GPM while the HL is rated 30 GPM (7 m3/h).