Viking Pump K8124A Sealless Mag Drive Internal Gear Pump
Description
Overview
Viking Pump K8124A is a cast iron internal gear pump with a sealless magnetic drive, built to move 80 GPM (18 m3/h) at 780 rpm through 2 inch NPT ports. Because the outer magnet drives the rotor through a 316L stainless canister, there is no dynamic shaft seal to weep, and every drop of liquid stays inside the pump body. That is the whole point of the 8124A family, and the K size is the one that tends to be picked for mid-sized transfer duties on solvents, polyols, resins and other liquids that are hazardous or simply awkward to seal. Seven Star LLC is an independent supplier serving Oman and the GCC.
What follows is a read-through of the Viking catalog section for the family, written for engineers and buyers who have a Viking Pump K8124A on a drawing or a spare parts list and want to confirm that it is the right pump before sending an enquiry.
How the Viking Pump K8124A sealless drive works
Behind the pump casing sits a bracket that carries a bearing assembly with an outer magnet ring. Inside the canister, an inner magnet ring is fixed to the rotor shaft. As the motor turns the outer ring, magnetic force passes through the canister wall and carries the inner ring and rotor around with it. A stepped housing keeps the outer magnet from touching the canister if a bearing should ever fail, and tapered roller bearings hold the outer magnet securely. Nothing rubs on a shaft seal, so nothing needs a seal flush, a barrier fluid or a leak monitor.
A small stream of the pumped liquid is routed from the discharge side between the shaft and its bushing and through the hollow shaft and idler pin back to suction. It cools the magnet area and keeps the product from overheating inside the canister. Reverse the flow direction and that cooling circuit reverses with it, which is one reason the manual tells you to think about the relief valve position when changing rotation.
Viking Pump K8124A data from the catalog
| Parameter | Value |
|---|---|
| Model | Viking Pump K8124A, series 8124A, sealless mag drive, catalog section 1403 |
| Port size | 2 inch (50 mm), tapped for NPT |
| Nominal capacity | 80 GPM (18 m3/h) at 780 rpm |
| Casing, head and bracket | Cast iron, ASTM A48 Class 35B |
| Rotor | Cast iron ASTM A48 Class 35B; steel ASTM A148 Grade 80-50 optional |
| Rotor shaft and idler pin | Hardened steel, ASTM A108 Grade 1045 |
| Bushings | Carbon graphite standard; hardened cast iron or silicon carbide optional |
| Canister | 316L stainless steel |
| Magnets | Neodymium iron boron standard; samarium cobalt above 225 F (105 C) |
| Maximum hydrostatic pressure | 550 PSIG (38 bar) |
| Maximum discharge pressure | 200 PSIG (14 bar) |
| Temperature, standard pump | 225 F (105 C) |
| Temperature, high temperature construction | 500 F (260 C) |
| Viscosity range, series | 28 to 250,000 SSU (1 to 55,000 cSt) |
| Shipping weight with valve | 195 lb (88 kg) |
How K8124A differs from other 8124A variants
The family runs from the H8124A at 15 GPM up to the QS8124A at 500 GPM. Within it, the Viking Pump K8124A sits one step above the HL8124A, which delivers 30 GPM at 1750 rpm through 1 1/2 inch ports and weighs 60 lb. The K size delivers nearly three times that flow at less than half the shaft speed and carries 2 inch ports. Its next neighbour, the KK8124A, shares the 2 inch ports and the 195 lb weight but is rated 100 GPM. Above it, the L8124A delivers 135 GPM at 640 rpm at 280 lb. All of H through L keep a 550 PSIG hydrostatic rating, whereas the LQ to QS sizes drop to 300 PSIG because of their flanged ports.
Typical uses in Oman and the GCC
Chemical blending sites, resin plants and polyol or isocyanate transfer stations are the natural home for a pump like this, together with fuel additive dosing skids and solvent loading racks at industrial ports. The sealless layout keeps vapour out of the plant, which helps where emission targets are strict. Viscosity can range from 28 to 250,000 SSU, so thin solvents and heavy syrups can use the same pump with different speeds. The catalog also notes short-term dry running capability, useful when clearing a line or emptying a tank to the last drop.
Features and options worth knowing
- Revolvable pump casing in 90 degree steps, giving four port positions without re-piping.
- Adjustable internal relief valve as standard; return-to-tank and jacketed valve options are listed.
- Head shims give adjustable end clearance to suit liquid viscosity or temperature.
- Static O-rings at key joints for liquid containment.
- Temperature monitor port available as an option; ATEX conforming pumps can be supplied.
- Same footprint as the matching Universal Product Line pump, so a packed or mechanically sealed unit can be upgraded without moving the base.
Selection and installation notes
Check the liquid temperature first. The standard pump with neodymium magnets is rated to 225 F (105 C), and anything hotter needs samarium cobalt magnets and the high temperature construction rated to 500 F (260 C) in the catalog. Next, compare the discharge pressure with the relief valve setting and the 200 PSIG limit, and remember that the quoted flow is for medium viscosity liquids with clockwise rotation, with slightly lower output on thin liquids when turned the other way. Size the motor for the cold start viscosity rather than the running value.
Mount the pump on a rigid base with a coupling or reducer matched to the drive, keep the suction line short and large, and fit a strainer upstream because the bushings run on the liquid itself. Fill the casing before the first start. After installation, turn the shaft by hand and check that the bearing carrier rotates without scraping.
Maintenance and spares
With no shaft seal to replace, routine attention shifts to bushings, thrust washers and the bearings that carry the outer magnet. The catalog lists carbon graphite bushings as standard and silicon carbide or hardened cast iron when the liquid is abrasive. Record the running temperature and the motor current at commissioning so that later changes stand out. When ordering spares, quote the complete model string from the nameplate, since the coupling and drive codes after the series number are part of it.
Related items you may also need: KRACHT KF 3/112 F10B P00 7DP2 Transfer Gear Pump | KRACHT RG 42-Z50/55-Z75/42 Coupling for KF Gear Pump | Allweiler OptiFix Progressing Cavity Pump AEB 2E-MF and 1F-MF | All Viking Pump products.
Points to confirm for the Viking Pump K8124A
- If the Viking Pump K8124A is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Viking Pump K8124A request we confirm the exact code and lead time in writing.
- Dimensions, ratings and connection data for the Viking Pump K8124A are in the datasheet attached to this page.
- The Viking Pump K8124A belongs to our positive displacement pumps range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Viking Pump K8124A on critical service often hold a spare unit in the store.
Documents and quotation
The Viking catalog section for the 8124A family, with dimensions, materials, the model key and operating limits, is attached to this page. To request a quotation for Viking Pump K8124A, send us the quantity, the liquid and temperature, the drive arrangement and your delivery location in Oman or the GCC. Please include the full nameplate string if you are replacing an installed unit.
Datasheets & Documents
- Datasheet Viking Pump K8124A Sealless Mag Drive Internal Gear Pump Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.
Viking Pump company profile
| Founded | 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth |
|---|---|
| Headquarters | Cedar Falls, Iowa, USA |
| Ownership | A unit of IDEX Corporation since 1989 |
| Core technology | Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps |
| Typical liquids | Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives |
| Standards | API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot |
Milestones
- 1904: Jens Nielsen patents his internal gear pump design.
- 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
- 1989: Viking becomes part of IDEX Corporation.
- 2011: Viking marks 100 years in Cedar Falls.
- Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.
How a Viking internal gear pump works
An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.
Where Viking pumps are used in Oman and the GCC
In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.
Viking Pump models we list
| Family | Examples |
|---|---|
| General-purpose internal gear pumps | KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A |
| Jacketed and heated pumps | KK224C, Q224C, M224A, KK124E asphalt |
| Steel and stainless steel pumps | L123C, QS4123C, RS4323A, KK127C, Q4127C |
| API 676 pumps | LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA |
| Motor speed, external gear and mag drive pumps | HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive |
| Special-duty pumps | KK4924A ammonia, KK4624C abrasive, LVP41027 vane |
Ordering Viking pumps: what we need
Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.
Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.
Browse Viking Pump products by category: Positive Displacement Pumps.
FAQ
Questions about the Viking Pump K8124A Sealless Mag Drive Internal Gear
Answers from our engineering team on installation, compatibility and integration.
01What flow does the Viking Pump K8124A deliver?
The catalog rates the K8124A at 80 GPM (18 m3/h) at 780 rpm on medium viscosity liquid with clockwise rotation, through 2 inch NPT ports.
02Does the K8124A have a shaft seal?
No. It is a sealless mag drive pump. The rotor is driven through a 316L stainless canister, so no dynamic shaft seal is needed.
03What are the temperature limits of the K8124A?
The standard pump with neodymium magnets is rated to 225 F (105 C). Samarium cobalt magnets and high temperature construction are listed for up to 500 F (260 C).
04What is the shipping weight of the K8124A?
The catalog gives approximately 195 lb (88 kg) for the pump with relief valve, before any coupling, base or motor is added.
05Can the K8124A run dry?
The catalog states that the 8124A series can run dry for short periods, such as clearing lines when unloading, but it is not intended for continuous dry running.