Brand:

SERVOMEX MultiExact 5400 Dual-Stream Oxygen Analyzer

Description

Overview

An air separation unit has many sampling points and only so much room in its analyzer house. The SERVOMEX MultiExact 5400 was developed for that situation. It is a digital multi-gas analyzer for industrial gas monitoring that can follow one or two streams at once, using a choice of two sensing technologies in a single 19 inch chassis. Seven Star LLC is an independent supplier serving Oman and the GCC. The facts on this page are taken from the manufacturer’s brochure for the SERVOPRO MultiExact 5400 and describe the unit as it is published there.

Measurement channels of SERVOMEX MultiExact 5400

Three measurement types are available. Paramagnetic sensing covers oxygen purity from 0 to 100 percent with an intrinsic error of plus or minus 0.01 percent oxygen. Paramagnetic sensing is also used for oxygen control from 0 to 100 percent with plus or minus 0.1 percent accuracy. Zirconia sensing serves oxygen trace work from 0 to 210,000 ppm with plus or minus 0.1 ppm accuracy. Repeatability is better than 0.01 percent for purity, better than 0.1 percent for control and better than 0.1 ppm for trace, and the T90 response is under 10 seconds at sample flows of 200 millilitres per minute for the percent channels and 400 millilitres per minute for the trace channel.

Specification table for SERVOMEX MultiExact 5400

Characteristic Published value
Technologies Paramagnetic and zirconia, both non-depleting
Streams Single or dual simultaneous gas monitoring
O2 purity range and accuracy 0 to 100 percent, plus or minus 0.01 percent O2
O2 control range and accuracy 0 to 100 percent, plus or minus 0.1 percent O2
O2 trace range and accuracy 0 to 210,000 ppm, plus or minus 0.1 ppm
Zero drift per week Plus or minus 0.01 percent (purity), 0.05 percent (control), 1 percent of reading or 250 ppb (trace)
Analog outputs Isolated 4-20 mA or 0-20 mA, one per channel; isolated 0-10 V option
Relays Four volt-free single pole relays, 30 V at 1 A, NAMUR compliant
Digital communications Modbus ASCII or RTU on RS485, Profibus on RS485, Ethernet Modbus TCP
Flow alarm One per channel, using Flowcube F3 sensor; not available for O2 purity
Sample pressure 35 plus or minus 21 kPa (5 plus or minus 3 psig)
Sample condition Oil free, non-corrosive, non-condensing, non-flammable, vented to atmosphere
Dimensions 132 mm high x 482 mm wide x 458 mm deep
Weight Less than 12 kg (26 lb)
Compliance IEC 61010-1, North American approval, Overvoltage Category II, Pollution Degree 2

How SERVOMEX MultiExact 5400 differs from other SERVOPRO analyzers

The MultiExact 4100, an earlier model in the same family, is the simpler multi-gas unit. The 5400 adds the option of dual-stream measurement, a colour touch interface with auto-validation, more digital protocols including Profibus and Ethernet, and the integrated stream switching valve block option. Compared with the single-gas MonoExact DF310E, which concentrates on trace oxygen, the SERVOMEX MultiExact 5400 also covers percent-level purity through paramagnetic cells. Choose the 5400 when one analyzer must handle product purity and ppm trace on separate streams, or when a medical gas assay needs a method accepted by the European and US pharmacopoeias.

Typical duties in the Gulf

Industrial gas companies in the region use analyzers of this class for purity release of oxygen, nitrogen and argon on air separation plants, for bottling and filling lines and for validating medical oxygen, nitrogen and air. The brochure states that the paramagnetic oxygen measurement is compliant with the US and European pharmacopoeias. Because the zirconia trace cell works from ppm up to 21 percent, it can also be used in nitrogen and argon product lines that occasionally see air ingress.

Operation and sampling

The analyzer provides easy access to alarm, fault and calibration history logs and independent auto-validation or calibration for each measurement. A pressure-driven or flow-driven sample system can be selected, and up to four fascia-mounted items can be chosen from a sample filter for the paramagnetic measurement, a sample flowmeter and a bypass flowmeter. The unit can be installed on a bench, in a panel or in a 19 inch rack, and three power lead formats are offered: UK, European and North American.

Why two sensing technologies matter

Paramagnetic and zirconia sensors answer different questions. A paramagnetic cell exploits the fact that oxygen is drawn into a magnetic field while most other gases are not, which gives a selective and very stable reading at percent levels, almost independent of the background mixture. A zirconia cell generates a voltage that depends on the ratio of oxygen across a heated ceramic, which makes it exceptionally sensitive in the parts per million region. Having both in one case lets a plant use identical operator screens, spare parts and training for purity and trace duties, and neither technology consumes itself in service, so the cost of ownership stays low over years. Selecting the sensor for each stream is therefore the first design decision on any new order.

Installation notes

Route the sample through suitable filtration and a pressure regulator so that the inlet falls within the 35 kPa window. Vent the exhaust to a safe location at atmospheric pressure, leave clearance around the case and connect the analog and digital outputs according to the channel configuration ordered. For multi-stream use choose the optional valve block, which brings stream selection inside the analyzer and reduces external tubing.

Care and calibration

Both sensing technologies are non-depleting and low drift, so the brochure promises long calibration intervals and long cell life. Periodic auto-validation can confirm readings against a reference gas without manual intervention. Keep the sample system clean and dry, and replace filters when flow indications fall.

Ordering notes

State the number of channels, the gas and range for each, the communication protocol, mounting style, the optional valve block and the power lead. If your plant already runs a MultiExact, quote the serial number so that compatible options can be advised. If a field in the order code is not clear, confirm the full order code on the nameplate.

Related items you may also need: Servomex S4000984 Rack Mount Kit Short Chassis for SERVOPRO 4900 | Servomex S2500986 Chopper Motor for SpectraExact 2500 | Servomex S1802989B Solvent Resistant O2 Transducer Oxy 1800 | All SERVOMEX products.

Documents and quotation

The manufacturer brochure with technical data for the SERVOMEX MultiExact 5400 is attached to this page. Please send your RFQ with SERVOMEX MultiExact 5400, the channel configuration, quantity and your delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet SERVOMEX MultiExact 5400 Dual-Stream Oxygen Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.

Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.

SERVOMEX company profile

Founded 1952, United Kingdom
Founders Richard Steel, John Crockett and Ronald Mudie
Headquarters Jarvis Brook, Crowborough, East Sussex
Ownership Spectris plc, since 1999
Key technologies Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981)
Product families MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers

Milestones

  • 1952: Servomex is founded.
  • 1961: The first Servomex paramagnetic oxygen analyser is introduced.
  • 1981: Servomex introduces zirconia oxygen sensors.
  • 1999: Spectris acquires Servomex.

Servomex analyzer families listed

Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:

  • SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
  • SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
  • SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
  • SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
  • SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
  • SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer

A flow alarm relay box for the 2700 flue gas analyzer is also listed.

Where Servomex gas analyzers are used

Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.

SERVOMEX products we list

Family Examples
Gas Analyzer Systems SERVOPRO 4900 Multigas Analyzer, SERVOPRO NanoTrace DF-550E Ultra-Trace O…, SERVOTOUGH Laser 3 Plus Combustion TDL G…, SERVOTOUGH OxyExact 2200 Oxygen Analyzer, ServoTough SpectraExact 2500 Gas Analyzer
Portable Test & Measurement Micro i.s. 5100 Portable Oxygen Analyzer
Gas Analyzer Accessories Tough Flue Gas 2700 Flow Alarm Relay Box

Ordering Servomex analyzers and spares: what we need

A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.

Facts checked against Servomex's own 70-year history and company profiles, October 2026.

FAQ

Questions about the SERVOMEX MultiExact 5400 Dual-Stream Oxygen Analyzer

Answers from our engineering team on installation, compatibility and integration.

01What gases and ranges does the SERVOMEX MultiExact 5400 measure?
It measures oxygen: purity and control from 0 to 100 percent using paramagnetic cells and trace from 0 to 210,000 ppm using a zirconia cell, in one or two streams.
02How accurate is the SERVOMEX MultiExact 5400?
Intrinsic error is plus or minus 0.01 percent O2 for purity, 0.1 percent O2 for control and 0.1 ppm for trace, with T90 response under 10 seconds.
03Which communications does the MultiExact 5400 support?
It supports Modbus ASCII or RTU on RS485, Profibus on RS485 and Ethernet Modbus TCP, plus isolated 4-20 mA or 0-20 mA analog outputs and four NAMUR relays.
04How big is the SERVOMEX MultiExact 5400?
The chassis is 132 mm high, 482 mm wide and 458 mm deep, weighs less than 12 kg and fits a bench, a panel or a 19 inch rack.
05Can the MultiExact 5400 be used for medical gas validation?
The brochure says the paramagnetic oxygen measurement complies with the European and US pharmacopoeias and can validate medical oxygen, nitrogen and air.