Brand:

SERVOMEX MultiExact 4100 SERVOPRO Multi-Gas Analyzer

Description

Overview

An air separation plant rarely needs just one gas measured at one point, and the SERVOMEX MultiExact 4100 is built for that reality. This SERVOPRO analyzer is a digital, safe-area, multi-gas instrument that measures up to four sample streams at once, using paramagnetic, zirconia, infrared and aluminum oxide sensing technologies chosen per channel. It targets industrial and medical gas manufacturers who need purity, control and trace measurements from a single bench-top or rack-mount unit. Seven Star LLC is an independent supplier serving Oman and the GCC.

Features of the SERVOMEX MultiExact 4100

  • Third-generation platform built on more than 60 years of Servomex experience, with an icon-driven colour touchscreen interface.
  • Up to four gas streams measured simultaneously, with plug-and-play sensor replacement and ultra-stable, non-depleting digital sensing technologies.
  • Plug and play support for the AquaXact 1688 aluminum oxide moisture transmitter.
  • Up to 32 alarms and 32 relays, four analog outputs and four analog inputs for external temperature, pressure or gas signals.
  • USB serial port for data logging and software upgrades; analyzer configurations transfer to other platform analyzers via a USB thumb drive.
  • Auto-calibration function and self-diagnostics, with system files that can be emailed to remote service experts.

SERVOMEX MultiExact 4100 technical specifications

Technologies Paramagnetic and zirconia for O2; SBSW IR, SBDW IR and GFx infrared for other gases
O2 purity (paramagnetic) 0-100 percent; accuracy plus or minus 0.01 percent O2; zero drift plus or minus 0.01 percent O2 per week; T90 under 10 s at 200 ml/min
O2 control (paramagnetic) 0-210,000 ppm; zero drift plus or minus 0.05 percent O2 per week
O2 trace (zirconia) 0-5 / 100 ppm; accuracy 1 percent of reading or less than 0.1 ppm; zero drift plus or minus 0.25 ppm
Trace CO2 (GFx infrared) 0-50 / 500 ppm; 1 percent of reading or less than 0.5 ppm; zero drift plus or minus 0.2 ppm
Trace CO and CH4 (GFx infrared) CO 0-50 / 500 ppm, CH4 0-10 / 50 ppm; T90 under 20 s at 2000 ml/min
Percent CO2 and CO SBSW or SBDW infrared, ranges from 0.2 to 100 percent
Analog outputs One 4-20 mA per measurement standard; 2 x 4-20 mA per transducer optional; 0-10 V optional
Analog / digital inputs Up to 4 x 4-20 mA; up to 8 digital inputs
Relays / alarms 4 relays standard (8 with autocal), up to 32 relays rated 30 V, 1 A; 2 alarms standard, up to 32
Digital communications RS232/RS485 Modbus, PROFIBUS, Ethernet Modbus TCP/IP (all optional)
Sample conditions 5 to 40 C, dew point 5 C below minimum ambient, oil free, non-condensing, non-flammable, particulates 2 micron
Sample flow 2 to 15 l/min depending on transducers; inlet 1/8 inch NPT male, outlet 1/4 inch NPT female
Bench-top size 432 x 141.2 x 543.6 mm (w x h x d); 482.6 mm wide rack version
Weight Main unit approx 14 kg; expansion chassis approx 13.7 kg
Operating environment 5 to 40 C, 10 to 90 percent RH non-condensing, ambient pressure 101.3 kPa plus or minus 10 percent

Sensing technologies inside the SERVOMEX MultiExact 4100

Oxygen can be measured by paramagnetic cells for percentage purity and control ranges, or by zirconia for trace ppm levels, while other gases rely on gas filter correlation infrared (GFx) or single beam single wavelength and single beam dual wavelength infrared. The datasheet gives each combination its own accuracy and drift figures, for example a plus or minus 0.01 percent O2 zero drift per week for the paramagnetic purity range and plus or minus 0.2 ppm for trace CO2. Because the transducers are digital and plug-and-play, a plant can add a stream or change a range later by fitting another transducer instead of buying a new analyzer.

Applications in Oman and the GCC

Key applications listed are product purity and process control on air separation plants, monitoring trace CO2 on the scrubbed air inlet to an ASU, validation of medical oxygen, nitrogen, air and helium, and mobile laboratories. The datasheet states that a USP and European Pharmacopoeia compliant method is available for the assay of medical oxygen and medical air. Oman and the GCC host industrial gas producers, hospital oxygen plants and nitrogen generators, all of which need this kind of multi-stream purity monitoring.

How MultiExact 4100 differs from other SERVOPRO analyzers

  • MultiExact 4100 is a safe-area analyzer that can mix up to four streams and technologies; MonoExact DF310E measures one gas, oxygen, with a single dedicated sensor.
  • It adds PROFIBUS and Ethernet options and up to 32 relays, which smaller single-gas analyzers lack.
  • It supports plug and play transducer swaps, unlike older fixed-configuration analyzers.

Installation and commissioning

Install on a bench or in a 19 inch rack in a safe area at 5 to 40 C. Connect each sample outlet to a separate atmospheric vent that has no back pressure, and keep the sample oil free, non-condensing and filtered to 2 micron. Wire the analog outputs, relays and any digital protocol, then run the auto-calibration set-up. Configuration files can be saved to a USB drive and copied to other platform analyzers.

Maintenance

With non-depleting sensing there is no sensor replacement cost, and recalibration is needed only at extended intervals, supported by independent auto calibration. Keep the inlet filtration serviced and review self-diagnostic messages.

Related products and ordering notes

For a quotation on MultiExact 4100, state the gas streams, the ranges, the sensor technologies, the mounting form, and the communications and relay options required.

Related items you may also need: Servomex S2500913 Ethernet Communications Board for SpectraExact 2500 | Servomex 2377-3831 Stainless Steel External Filter Unit for SERVOPRO | Servomex 2346-3073 6 mm OD SS Adaptor for Oxy 1900 | All SERVOMEX products.

Before placing an order for the SERVOMEX MultiExact 4100, compare the exact designation on your existing nameplate or bill of materials with the code shown on this page, because small differences in suffix letters often indicate a different option set. Sharing a photo of the nameplate with the enquiry helps the sales team confirm the match quickly and avoids an incorrect shipment to site.

Documents and quotation

The product datasheet for the MultiExact 4100 is attached on this page. To check availability, send an RFQ to Seven Star LLC with the model MultiExact 4100, the quantity and your destination in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet SERVOMEX MultiExact 4100 SERVOPRO Multi-Gas Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.

Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.

SERVOMEX company profile

Founded 1952, United Kingdom
Founders Richard Steel, John Crockett and Ronald Mudie
Headquarters Jarvis Brook, Crowborough, East Sussex
Ownership Spectris plc, since 1999
Key technologies Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981)
Product families MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers

Milestones

  • 1952: Servomex is founded.
  • 1961: The first Servomex paramagnetic oxygen analyser is introduced.
  • 1981: Servomex introduces zirconia oxygen sensors.
  • 1999: Spectris acquires Servomex.

Servomex analyzer families listed

Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:

  • SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
  • SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
  • SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
  • SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
  • SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
  • SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer

A flow alarm relay box for the 2700 flue gas analyzer is also listed.

Where Servomex gas analyzers are used

Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.

SERVOMEX products we list

Family Examples
Gas Analyzer Systems SERVOPRO 4900 Multigas Analyzer, SERVOPRO NanoTrace DF-550E Ultra-Trace O…, SERVOTOUGH Laser 3 Plus Combustion TDL G…, SERVOTOUGH OxyExact 2200 Oxygen Analyzer, ServoTough SpectraExact 2500 Gas Analyzer
Portable Test & Measurement Micro i.s. 5100 Portable Oxygen Analyzer
Gas Analyzer Accessories Tough Flue Gas 2700 Flow Alarm Relay Box

Ordering Servomex analyzers and spares: what we need

A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.

Facts checked against Servomex's own 70-year history and company profiles, October 2026.

FAQ

Questions about the SERVOMEX MultiExact 4100 SERVOPRO Multi-Gas Analyzer

Answers from our engineering team on installation, compatibility and integration.

01How many streams can the MultiExact 4100 measure?
It measures up to four gas streams simultaneously using paramagnetic, zirconia, infrared or aluminum oxide technologies selected for each channel.
02Which communications does the MultiExact 4100 support?
Analog 4-20 mA and optional 0-10 V outputs, plus optional RS232/RS485 Modbus, PROFIBUS and Ethernet Modbus TCP/IP.
03What sample conditions does the MultiExact 4100 need?
Sample must be 5 to 40 C, oil free, non-condensing and non-flammable, filtered to 2 micron, at 2 to 15 l/min depending on the transducers fitted.
04How many relays and alarms does the MultiExact 4100 offer?
It has 4 relays and 2 alarms as standard, expandable to up to 32 relays rated 30 V and 1 A and up to 32 alarms.
05Does the MultiExact 4100 support moisture measurement?
Yes. It has plug and play support for the Servomex AquaXact 1688 aluminum oxide moisture transmitter.