- Automation & ControlView all 2,923 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: SERVOMEX
Servomex S4000979 Mains Fuses T5.0 A 85-132 V for SERVOPRO 4900
Description
Servomex S4000979 Mains Fuses T5.0 A 85-132 V for SERVOPRO 4900: overview
Servomex S4000979 is the pack of 10 mains fuses, 20 mm T 5.0 A HBC, for 85 to 132 V operation, listed in the 4900 spare parts list. The SERVOPRO 4900, also called the xentra 4900 or Multigas, is a modular continuous emissions analyser. The xentra chassis takes up to three modular gas sensors, powers them, supplies the gas connections and calculates sample gas concentrations, which appear on an LCD screen and on the analogue and RS232 serial outputs. It also supports two external analogue inputs. The part is catalogued for the SERVOPRO 4900 (xentra) continuous emissions analyser, and this page describes Servomex S4000979 so that maintenance teams, procurement staff and planners can confirm they are asking for the right item before they raise a request.
This is the lower-voltage counterpart of the 4900 mains fuse pack (S4000978 covers 170 to 264 V). It holds 10 fuses of 20 mm, T 5.0 A, high breaking capacity, intended for 85 to 132 V operation. The manual marks it as a recommended spare and says the electrical supply should be fused at 6 A.
Seven Star LLC offers S4000979 as an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Quote S4000979 exactly as written, because spare part numbers in this analyser family are similar in form and a single wrong character points to a different item.
Key features of S4000979
- Exact part number S4000979, taken from the manufacturer’s own spares documentation for the SERVOPRO 4900.
- Described in the source document as pack of 10 mains fuses, 20 mm T 5.0 A HBC, for 85 to 132 V operation, listed in the 4900 spare parts list.
- Intended for the SERVOPRO 4900 (xentra) continuous emissions analyser; the document links the part to the analyser model rather than to a generic category.
- The manual marks this fuse pack with an asterisk as a recommended spare.
- Useful for planned maintenance and for fast recovery when a fault such as a blown mains fuse on an analyser set for the 85 to 132 V range has been traced to this item.
- Supplied on a request-for-quotation basis with the part number, quantity and analyser serial number confirmed.
Technical specifications for S4000979
| Parameter | Value |
|---|---|
| Manufacturer | Servomex |
| Part number | S4000979 |
| Description | Mains Fuses T5.0 A 85-132 V for SERVOPRO 4900 |
| Item | Main power fuses, 10 off |
| Fuse type | 20 mm, T 5.0 A, HBC |
| Mains range | 85 to 132 V |
| Marked in manual | Recommended spare |
| Host analyser | SERVOPRO 4900 xentra continuous emissions analyser |
| Operating temperature | 5 to 45 degrees C |
| Storage temperature | -20 to +60 degrees C |
| Weight | Nominally 20 kg, up to 22 kg |
| Recommended supply fuse | 6 A |
| Installation category | II |
The values above are taken from the manufacturer’s documents for the SERVOPRO 4900. Figures in the host analyser rows describe the complete instrument, not the individual part S4000979, and are given so that you can check that the analyser in your plant belongs to the same family.
Typical applications in oil, gas, utilities, water and manufacturing
Emissions analysers of this class are used for stack and process monitoring in power generation, refining, petrochemical and manufacturing plants. Where older 4900 units remain in service in Oman and the GCC, replacement of consumable parts such as fuses, filters and mounting hardware keeps them running.
In oil and gas, power, utilities, water treatment and general manufacturing plants in Oman and the GCC, an analyser that is out of service can leave a process without its measurement, so maintenance planners keep a list of exact spare part numbers. Part S4000979 belongs on that list for sites that run the SERVOPRO 4900. Having the part number, the analyser serial number and the fault history ready shortens the time between a diagnosis and an order.
Spare part searches are rarely casual. A maintenance planner usually holds a fault report, an analyser serial number and a part number copied from a manual or from a removed component. Matching those three pieces of information against the manufacturer’s documentation avoids the cost of ordering the wrong item and the downtime that follows. Where an analyser family has been in service for many years, the printed numbers in older manuals remain the dependable way to identify an item, which is why this page repeats the exact designation and the table in which the manufacturer lists it. Whenever a description in a stores system differs from the manufacturer’s wording, trust the part number and confirm the rest by asking.
Selection and compatibility notes for S4000979
The manual says that when ordering spares you should always give the model and serial number of the analyser, which is on the identification label on the underside of the analyser. It also warns that there are no user serviceable parts inside the xentra 4900, so servicing should be referred to qualified personnel.
Servomex lists the 4900 as an obsolete product, and its support page gives service and spare parts availability as Limited, with a recommendation to consult Servomex.
Before you order S4000979, run through this checklist:
- Read the identification label of the analyser and note the model and the serial number.
- Confirm that the description Mains Fuses T5.0 A 85-132 V for SERVOPRO 4900 matches the item you removed or the item the fault points to.
- Check the related part numbers in the same documentation, because a neighbouring item may be the real need.
- Tell us the quantity and any delivery point in Oman or elsewhere in the GCC when you send the request for S4000979.
Installation and commissioning of S4000979
Servicing of the analyser should be carried out by suitably qualified personnel using the manufacturer’s service documentation. Before work on S4000979, isolate the analyser from its supply, release any sample pressure, make the area safe for the sample gas in use and follow the warnings in the manual. Handle the part with care, keep any contact surfaces clean and compare the replacement with the removed item before it is fitted.
After S4000979 has been fitted, close the enclosure correctly, restore power and the sample flow, allow the analyser to stabilise, and then check the calibration and the alarm and output functions against the plant procedure. A typical reason to fit this part is a blown mains fuse on an analyser set for the 85 to 132 V range.
Maintenance and spares planning for S4000979
The manual marks this fuse pack with an asterisk as a recommended spare. Plants that run several analysers usually hold stock by fleet size, and a record of when S4000979 was last changed makes the next change easier to plan. Keep the removed item with a note of the date and the fault description, because that history helps when later faults appear.
Related Servomex spares and ordering notes
Other 4900 spare parts in the same list include the fuse packs S4000978 and S4000979, the signal socket kit S4000986, the fan filter element 2388-1981, the rack mount kits S4000984 and S4000985, and the sample filter kits S4000987 and S4000988. If you are not sure whether S4000979 is the right item, send the analyser model and serial number and the symptom, and we will compare them with the manufacturer’s lists before quoting.
S4000979 frequently asked questions
The questions below cover the points buyers raise most often about S4000979: what the item is, which analyser it fits, what to send with an order, what the manufacturer says about its status, and how Seven Star LLC supplies it in Oman and the GCC.
Documents and quotation
The manufacturer’s document that lists S4000979 is available as a datasheet download on this page, and it also shows the parts that sit around it in the analyser. To receive a quotation, send us the RFQ with the part number S4000979, the quantity, the analyser model and serial number, and the delivery location. Seven Star LLC replies with availability and lead time for Oman and the GCC.
Other Models in the Servomex 49 Range
Seven Star LLC supplies models from the Servomex 49 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex S4000978 Mains Fuses T3.15 A 170-264 V for SERVOPRO 4900 | Gas Analyzer Systems | View details |
| Servomex S4000979 Mains Fuses T5.0 A 85-132 V for SERVOPRO 4900 | Gas Analyzer Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Servomex S4000979 Mains Fuses T5.0 A 85-132 V for SERVOPRO 4900 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex S4000979 Mains Fuses T5.0 A 85-132 V for
Answers from our engineering team on installation, compatibility and integration.
01What is Servomex S4000979?
Servomex S4000979 is the pack of 10 mains fuses, 20 mm T 5.0 A HBC, for 85 to 132 V operation, listed in the 4900 spare parts list. It is catalogued for the SERVOPRO 4900 (xentra) continuous emissions analyser and quoted by exact part number.
02Which analyser does S4000979 fit?
The manufacturer's documents link S4000979 to the SERVOPRO 4900 (xentra) continuous emissions analyser. Confirm the model and serial number on the identification label before ordering.
03What should I send when I request S4000979?
Send the part number S4000979, the quantity, the analyser model and serial number, and the delivery location in Oman or the GCC, so the quotation is accurate.
04Is S4000979 current or obsolete?
Servomex lists the 4900 as an obsolete product, and its support page gives service and spare parts availability as Limited, with a recommendation to consult Servomex. Availability of S4000979 is confirmed on request, because stock changes without notice.
05Does Seven Star LLC supply S4000979 in Oman?
Yes, Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ and we confirm availability for S4000979.


















Reviews