Servomex S2501905C CVDFET Detector Unit for SpectraExact 2500
Description
Servomex S2501905C: CVDFET detector for the 2500
Servomex S2501905C is the CVDFET detector unit in Table 6.4 of the SpectraExact 2500 series manual. In this analyser the infrared beam is chopped through interference filters, crosses the sample cell and finally lands on the detector in the left-hand end casting. The detector converts the alternating measurement and reference energy into the signals the transmitter board turns into concentration. The manual identifies three infrared units, CaF2, CVDFET and KRS-5, which are the part numbers S2501905A, S2501905C and S2501905B respectively, and refers to the Final Specification Sheet to decide which applies.
This summary lets maintenance planners confirm the detector variant before ordering. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Where the detector sits and what it touches
The construction section places the detector assembly together with the main electronic circuit boards in the detector end, with the display and control panel in the hinged lid. The detector faces the cell through a boss, which may be scrubbed or purged depending on the application. Scrubber marked parts such as the H2O, H2O/CO2 and H2O/CO2/CO versions in Table 6.6 protect the detector and cell bosses from cross-interference.
| Parameter | Value |
|---|---|
| Part number | S2501905C |
| Description | Detector, CVDFET, Table 6.4 |
| Siblings | S2501905A CaF2; S2501905B KRS-5; S2600905 photodiode (2520 only) |
| Location | Detector end, left side |
| Intrinsic error of analyser | Less than plus or minus 1 percent fsd |
| Repeatability | Plus or minus 0.5 percent fsd |
| Noise | Less than 1 percent fsd peak to peak at minimum T90 |
| Response T90 | User adjustable from 11 s minimum, electronic only |
| Obscuration tolerance | Less than plus or minus 3 percent fsd zero error for 50 percent broadband obscuration of the windows |
| Warm-up | Typically 2 to 10 h |
Differences from other detector units
- S2501905A: CaF2 detector, the first listed and the usual reference in the table.
- S2501905B: KRS-5 detector.
- S2501905C: CVDFET detector, the part on this page.
- S2600905: photodiode for the 2520 soft ultraviolet analyser only; it is not an infrared unit.
Diagnosing before replacing S2501905C
Detector faults look similar to cell faults, so work through the diagnostics. DETECTOR SIGNAL LOW is listed as probable cell contamination, to be cured by cleaning the cell; the manual recommends removing the cell when the reference detector signals fall below 50 percent of initial. COMPENSATION T SENSOR FAILURE points to the detector temperature sensor being failed or disconnected. DETECTOR SIGNAL HIGH is a serious fault that causes shutdown and may mean loss of an infrared filter or, in liquid analysers, no liquid in the cell. Only after these checks is a new detector justified.
Installation and checks
Open the left cover on its hinges, disconnect the detector leads while noting the connection to the sensor interface board, replace the unit, and reassemble with any scrubbers freshly fitted. After power-up allow the typical 2 to 10 hour warm-up before judging stability. Run a zero on a good zero sample and a span; the manual specifies drift of less than plus or minus 1 percent fsd per week for the 2500.
Spares and planning
Detectors are listed as refer to application in the recommended spares table; sites with four to nine analysers are advised to hold one. Combine the request with the sensor interface PCB 02000934 and the power supply S2000925 if you are building a two-year spares kit.
Where S2501905C is used
Typical homes are process infrared gas analysis duties in petrochemical, gas and power plants across the GCC, usually in hazardous areas where certified versions of the 2500 are specified.
Environmental limits that apply to the detector end are an operating temperature of 0 to 55 degrees Celsius, humidity of 0 to 95 percent non-condensing, and a rate of ambient temperature change below plus or minus 25 degrees per hour. The detector and its compensation temperature sensor respond to this, which is why the manual lists the compensation temperature among the diagnostic readings and why a sudden shade or heat load can move the zero.
The analyser supply is 115/230 V or 100/200 V AC plus or minus 15 percent at 50 or 60 Hz, 120 VA, or 300 VA when an electrically heated cell is fitted; supply voltage effects are below plus or minus 1 percent fsd for a 15 percent change. A new detector therefore should not be blamed for variations that follow the mains.
Orderers should also know that the Special Tools Kit S2500979 and PTFE tape are listed under sample cell spares, not detector spares, so a detector exchange needs no cell tooling. Keep the display and keypad assembly S2501999 in mind if the front lid must be worked on, because the display unit withdraws after its clamp and retaining bracket are released.
Ask for the detector together with its Final Specification Sheet reference when the analyser is a multi-component build, since the manual notes that most applications use one measurement and one reference wavelength per measured component and the detector type is part of that optical design.
Documents and quotation
The Servomex SpectraExact 2500 series manual, part number 02500005D, is the document we attach for Servomex S2501905C; its section 6 spares tables are the source of the part number and description. Please check the Final Specification Sheet for the detector type before ordering, because the three infrared detector units are not interchangeable. To request a quotation, send S2501905C, the quantity, the analyser serial number and the Final Specification Sheet reference if you have it, and your delivery location in Oman or the GCC. Each RFQ is answered with availability and lead time.
Other Models in the Servomex 2500 Range
Seven Star LLC supplies models from the Servomex 2500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex S2500931A Long Wave ZnSe Source Unit for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S2501905C CVDFET Detector Unit for SpectraExact 2500 | Gas Analyzer Systems | You are viewing this model |
| Servomex S2500980B BaF2 Window for SpectraExact 2500 | Gas Analyzer Systems | View details |
| Servomex S1200922 CW Boss Scrubber H2O/CO2 for SpectraExact 2500 | Gas Analyzer Systems | View details |
Datasheets & Documents
- Datasheet Servomex S2501905C CVDFET Detector Unit for SpectraExact 2500 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex S2501905C CVDFET Detector Unit for
Answers from our engineering team on installation, compatibility and integration.
01What is Servomex S2501905C?
S2501905C is the CVDFET detector unit listed in Table 6.4 Detector Spares of the SpectraExact 2500 series manual.
02Which other detector units are listed?
CaF2 S2501905A, KRS-5 S2501905B, and for the 2520 only the photodiode S2600905.
03Where is the detector located?
In the detector end, the left side of the analyser, which also holds the main circuit boards and the hinged display and control panel.
04What does a DETECTOR SIGNAL LOW fault indicate?
The manual lists it as probable cell contamination, so clean the cell before suspecting the detector.
05How many detectors should be stocked?
The recommended spares table gives 0 for one to three analysers and 1 for four to nine, with the type determined by the application.