Viking Pump AL493 Steel Externals Gear Pump 75 GPM 3 in
Description
Overview
Viking Pump AL493 is a steel-externals internal gear pump for petrochemical and general industrial duty, with 3 inch Class 300 flanged ports. It delivers 75 GPM (17 m3/h) at 1150 rpm on 60 Hz power or 95 GPM (22 m3/h) at 1450 rpm on 50 Hz power, which makes it the largest size in the 493 Series. The pump is foot mounted for horizontal installation and is furnished as standard with mechanical seal construction to limit liquid loss and protect the shaft. Seven Star LLC is an independent supplier serving Oman and the GCC.
If your plant specifies steel pressure parts for flammable or hot hydrocarbons, this series is the economical step above cast iron without moving to a full API 676 pump. It is also a sensible choice for maintenance teams and buyers who want a pump with a standard mechanical seal fitted at the factory, rather than assembling packing and a seal housing on site.
Where the Viking Pump AL493 sits in the range
Viking Pump builds the 493 and 4193 pumps in sizes up to 75 GPM, for use in general industry, the petrochemical sector and other industries. Accurate rotor and shaft positioning keeps the pump running at new-pump efficiency through years of heavy duty, according to the catalog description, and the foot-type bracket keeps alignment stable. The catalog gives separate dimension pages for the 493 build and the 4193 build, so confirm the suffix when you replace an existing pump.
Specification data
| Parameter | Value |
|---|---|
| Model | AL493, 493 Series, steel externals |
| Port size | 3 inch, Class 300 flanges |
| Capacity at 60 Hz | 75 GPM (17 m3/h) at 1150 rpm |
| Capacity at 50 Hz | 95 GPM (22 m3/h) at 1450 rpm |
| Maximum differential pressure | 250 PSIG (17 bar) |
| Maximum hydrostatic pressure | 400 PSIG (27 bar) |
| Maximum temperature | 350 F (175 C) |
| Series temperature range | 0 to +350 F (-20 to +175 C) |
| Viscosity range | 28 to 15,000 SSU (1 to 3,300 cSt) |
| Approximate shipping weight | 81 lb (37 kg) |
| Seal | Mechanical seal with FKM elastomers, standard from 0 to 350 F |
The catalog notes that extra internal clearances are required above 225 F (105 C), and that if suction pressure exceeds 100 PSI (7 bar) the factory must be consulted.
How AL493 differs from other 493 Series variants
The 493 Series has six sizes: GG, HJ, HL, AS, AK and AL. GG493 moves 10 GPM through 1 inch ports and weighs 18 lb (8 kg); HJ493 and HL493 move 20 and 30 GPM through 1-1/2 inch ports and weigh 40 lb (18 kg); AS493, AK493 and AL493 use 3 inch ports and move 35, 50 and 75 GPM at 1150 rpm, with weights of 80, 80 and 81 lb (36 to 37 kg), so the larger flow adds almost no weight. The AL493 is therefore the maximum capacity pump. The AL4193 counterpart has the same capacity but weighs 102 lb (46 kg).
Typical applications of AL493
Steel construction also allows the pump to tolerate higher piping loads and thermal stress than cast iron, a benefit in outdoor service in the Gulf where pipe temperatures swing with the sun. Refinery and terminal transfer of light and medium oils, additive blending, petrochemical process feed, ship and barge fuel transfer, and lubricant forwarding are all typical jobs. Steel pressure parts are favoured in these services for their mechanical robustness.
Selecting Viking Pump AL493 against pressure and viscosity
Because the pump is positive displacement, discharge pressure is fixed by the system, not by the pump, and the catalog limits tell you how much the pump can safely deliver. The differential pressure allowed falls as the liquid becomes thinner, because internal slip increases and the idler and bushings are less protected by a liquid film. For this reason the pressure limits below are given by viscosity band and should be compared with your duty.
- 250 PSI (17 bar) for liquids above 100 SSU (20 cSt).
- 150 PSI (10 bar) for 38 to 100 SSU (3 to 20 cSt).
- 100 PSI (7 bar) for liquids below 38 SSU (3 cSt).
- Suction pressure above 100 PSI requires factory consultation.
Installation
Plan the foundation: a steel externals pump with Class 300 flanges is often installed in a hydrocarbon area, so make sure the baseplate is grounded and the coupling guard is non-sparking. Foot mount the pump on a stiff baseplate, connect Class 300 flange piping with suitable gaskets and bolting, and align the drive with a flexible coupling. Check that piping loads do not distort the casing and prime the pump before starting. Guard all rotating parts, and pipe the relief valve discharge to a safe return. Record the first discharge pressure reading as a reference, and label the pump with its model code and flange rating.
Maintenance
Create a maintenance record from day one: first start date, discharge pressure, motor current and seal condition. Comparing these readings over time shows wear early. Check the mechanical seal regularly and replace the seal and elastomers together. Inspect bushings when bearing noise changes, and use performance data to detect wear. Keep spare seals and idler sets in stock, together with the relief valve spring and a set of flange gaskets. When a pump is removed for repair, check the shaft for seal-face wear and the idler pin for scoring before refitting, and record the findings so that the next purchase can specify an upgraded bushing or seal material if needed.
Related items you may also need: KRACHT KP 1/4 G10A X0A 4NL1 High-Pressure Gear Pump | NETZSCH NOTOS 4NS Geared Twin Screw Pump | Verder VA25 Air-Operated Double Diaphragm Pump | All Viking Pump products.
For the Viking Pump AL493, keep the downloaded document together with your purchase order and commissioning records. Having the manufacturer reference available at installation time simplifies acceptance checks, supports later spare-part planning and gives maintenance staff a single place to confirm wiring, mounting and setup information.
Documents and quotation
The attached catalog section covers the 493 and 4193 series with all sizes. To request a quotation for Viking Pump AL493, send the code AL493 and quantity through the RFQ form, together with the line frequency, flange standard and liquid details.
Datasheets & Documents
- Datasheet Viking Pump AL493 Steel Externals Gear Pump 75 GPM 3 in Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Viking Pump is a global leader in positive displacement pumping solutions, building internal and external gear pumps at its base in Cedar Falls, Iowa, as an IDEX company. Its range includes the 1124C Series internal gear pumps with U-Plus bracket design and O-Pro seal technology, GB-425 Series external gear pumps for pipeline injection, RTPg tanker pumps, and hygienic rotary lobe and circumferential piston pumps. These pumps move viscous and problematic liquids across industrial, energy, hygienic and transport applications, from lubrication, fuel transfer and chemical processing to asphalt and food-grade duty. Seven Star LLC is an independent supplier serving Oman and the GCC, helping buyers specify Viking Pump models matched to their liquid, flow rate and sealing needs for dependable uptime.
FAQ
Questions about the Viking Pump AL493 Steel Externals Gear Pump 75 GPM
Answers from our engineering team on installation, compatibility and integration.
01What is the capacity of the AL493?
AL493 is rated 75 GPM (17 m3/h) at 1150 rpm on 60 Hz, or 95 GPM (22 m3/h) at 1450 rpm on 50 Hz, through 3 inch Class 300 flanges.
02What temperature can AL493 handle?
The catalog lists a maximum of 350 F (175 C) with extra clearances above 225 F (105 C).
03What are the pressure limits of the AL493?
Maximum differential pressure is 250 PSIG (17 bar) for liquids above 100 SSU, with lower limits for thinner liquids, and hydrostatic pressure is 400 PSIG (27 bar).
04What seal does the AL493 use?
It is furnished as standard with a mechanical seal and FKM elastomers to minimise liquid loss and protect the shaft.
05What does the AL493 weigh?
The approximate shipping weight with relief valve is 81 lb (37 kg).