Brand:

Viking Pump KK127C Stainless Steel Gear Pump 65 GPM

Description

Overview

Viking Pump KK127C is a stainless steel internal gear pump for corrosive, high-purity or colour-critical liquids, rated 65 GPM (15 m3/h) at 520 rpm through 2 inch ports. It belongs to the 127C Series, the stainless counterpart of the cast iron 124C, and is built on the same U-Plus bracket so that packing, component seals, cartridge seals and the O-Pro Guard Seal can all be fitted. Seven Star LLC is an independent supplier serving Oman and the GCC.

Buyers choose stainless gear pumps when cast iron would rust or contaminate the product: solvents, acids and alkalis within material limits, food-grade oils outside sanitary rules, cosmetics bases, inks, pigments, polyols and a range of chemical intermediates.

Why stainless changes the duty

With stainless wetted parts the pump keeps working where iron corrodes, and the series temperature range widens to minus 120 to plus 500 F (minus 85 to plus 260 C). The 127C series maximum pressure is 175 PSI (12 bar), slightly lower than the 200 PSI of iron series, and the KK size is limited to 150 PSI (10 bar) discharge. The standard Viking Pump KK127C temperature rating in the specification table is 350 F (175 C).

Positive displacement flow is steady and low in shear, so shear-sensitive polymers and emulsions survive the trip. A pressure relief valve is standard on non-jacketed pumps, and a casing drain allows draining without removing the head.

Viking Pump KK127C data sheet figures

Parameter Value
Model Viking Pump KK127C, 127C Series, stainless steel, non-jacketed
Port size 2 inch
Nominal capacity 65 GPM (15 m3/h)
Rated speed 520 rpm
Maximum hydrostatic pressure 400 PSIG (28 bar)
Maximum discharge pressure 150 PSI (10 bar)
Maximum temperature, standard pump 350 F (175 C)
Series temperature range -120 to +500 F (-85 to +260 C)
Series maximum pressure 175 PSI (12 bar)
Viscosity range 28 to 2,000,000 SSU (0.1 to 440,000 cSt)
Shipping weight with valve 137 lb (62 kg)
Shaft sealing Packing (no digit before series number)

Difference between KK127C and its neighbours

Inside the 127C family the KK size is the second 2 inch pump. The code KK1127C is the O-Pro variant and KK4127C is the mechanical seal variant; both are rated to 350 F and are intended for sealed duty. Stepping down, K127C has a lower displacement and stepping up, L127C runs 2 inch ports at 640 rpm with higher capacity. The cast iron KK124C with the same size delivers 100 GPM at 780 rpm, so stainless gives lower flow because of its lower rated speed.

Where KK127C fits in Gulf industry

Desalination and water treatment plants use stainless gear pumps for viscous chemicals such as polymer concentrates. Petrochemical sites use them for additive and inhibitor dosing. Paint, resin and cosmetics factories use them for batch transfer. Pharmaceutical-adjacent processes with non-sanitary requirements also choose them. The pump suits marine and coastal environments where external corrosion is a concern, though the externals should be checked against the site atmosphere.

Selection pointers for Viking Pump KK127C

Corrosion data is the first filter. Stainless steel resists many liquids but not all; chlorides at high temperature, strong reducing acids and some hot caustic solutions can still attack it, so consult a compatibility chart for the exact concentration. Next consider the elastomers in seals and O-rings, which often have lower limits than the metal. Finally think about speed: at 520 rpm the KK size has relatively low slip with thick liquids, but with water-thin solvents the delivered flow falls and pressure capability drops, so check the performance curve for thin liquids.

  • Check corrosion resistance of stainless and elastomers against the actual liquid and temperature.
  • Decide between packing, O-Pro Guard Seal and single or double mechanical seals.
  • Verify the 150 PSI (10 bar) discharge limit at your viscosity.
  • Use ProPort casing options when matching existing flanges.
  • Request performance curves for slow-speed duty.

Drive and speed considerations

The rated speed of 520 rpm is well below the 1450 or 1750 rpm of standard motors, so a gear reducer, gearmotor or belt drive is required. Offset reducers allow the motor to sit beside the pump, saving length on a compact baseplate, while a purchased reducer in line with the pump saves width. Variable frequency drives work well with positive displacement pumps provided that the motor can deliver full torque at low speed, which matters with thick liquids. Allow for starting torque, as a cold, viscous charge may need twice the running torque.

Installation

Before installation, inspect the pump for shipping damage and rotate the shaft by hand to confirm free movement. Store the pump in a dry place with ports covered until piping is ready, because debris entering the casing damages the close-clearance gears. Use a rigid base, a spacer coupling and clean pipework. Flush the system before start-up, since welding debris can score stainless internals. If the liquid can crystallise on standing, install a flush connection. Fill the casing before starting and check the relief valve discharge path.

Maintenance

Keep a short list of critical spares for the Viking Pump KK127C: a packing set, an idler and idler pin assembly, a bushing set and a relief valve spring. Where the pump serves a process that cannot stop, consider a spare pump on the shelf with the same code, since stainless castings can have longer lead times than cast iron. Stainless steel galls if run dry, so protect the pump with a low-level cut-out. Inspect packing and bushings at fixed intervals, and keep spare idler and bushing kits. Use the rotatable bearing housing to reset end clearance when flow declines.

Related items you may also need: KRACHT KP 1/4 Q10A K0A 4NL1 High-Pressure Gear Pump | KRACHT BT / BTH Low-Speed Gear Pump | KRACHT KP 1/4 F10A K0A 4NL1 High-Pressure Gear Pump | All Viking Pump products.

Points to confirm for the Viking Pump KK127C

  • If the Viking Pump KK127C is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each Viking Pump KK127C request we confirm the exact code and lead time in writing.
  • Dimensions, ratings and connection data for the Viking Pump KK127C are in the datasheet attached to this page.

Documents and quotation

The attached catalog section covers the stainless non-jacketed 127C, 1127C, 4127C and larger 327A families. To request a quotation for Viking Pump KK127C, send the code Viking Pump KK127C and the quantity through the RFQ form, with liquid composition and temperature.

Datasheets & Documents
  • PDF Datasheet Viking Pump KK127C Stainless Steel Gear Pump 65 GPM Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is a global leader in positive displacement pumping solutions, building internal and external gear pumps at its base in Cedar Falls, Iowa, as an IDEX company. Its range includes the 1124C Series internal gear pumps with U-Plus bracket design and O-Pro seal technology, GB-425 Series external gear pumps for pipeline injection, RTPg tanker pumps, and hygienic rotary lobe and circumferential piston pumps. These pumps move viscous and problematic liquids across industrial, energy, hygienic and transport applications, from lubrication, fuel transfer and chemical processing to asphalt and food-grade duty. Seven Star LLC is an independent supplier serving Oman and the GCC, helping buyers specify Viking Pump models matched to their liquid, flow rate and sealing needs for dependable uptime.

FAQ

Questions about the Viking Pump KK127C Stainless Steel Gear Pump 65 GPM

Answers from our engineering team on installation, compatibility and integration.

01What flow does the KK127C deliver?
The KK127C is rated 65 GPM (15 m3/h) at 520 rpm through 2 inch ports for liquids of 100 SSU or thinner.
02What temperature can the KK127C pump?
The standard pump is listed to 350 F (175 C), while the 127C series covers minus 120 to plus 500 F depending on construction.
03What is the maximum discharge pressure of the KK127C?
The specification table lists 150 PSI (10 bar) maximum discharge pressure and 400 PSIG (28 bar) maximum hydrostatic pressure.
04Does the KK127C have a mechanical seal?
No, the code without a 4 or 1 before the series number is the packed version. KK4127C has a mechanical seal and KK1127C the O-Pro seal.
05How heavy is the KK127C?
The listed shipping weight with relief valve is 137 lb (62 kg).