Brand: MICHELL Instruments
Michell MDM50 Portable Hygrometer (Obsolete)
Description
Michell MDM50 portable hygrometer, an obsolete spot-check tool
The Michell MDM50 is a self-contained portable hygrometer in a yellow polypropylene case, made for on-site dew-point spot checks in compressed air, gas generators, railway pneumatics, plastic-moulding dryers, additive manufacturing and instrument air. The manufacturer’s product page marks it obsolete: it was replaced by the Easidew PDP Dryer Portable, with a last-time-buy order date of 30 April 2024, and customers are told to contact their local Michell sales or service contact for repair and servicing. That status makes MDM50 a typical spare-and-repair enquiry rather than a new-build choice, and this page describes the instrument as documented in its datasheet. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What MDM50 contains
Everything needed for a measurement is built into the case. A polymer thick-film SF82 sensor sits in a stainless-steel sample block with fixed orifice ports, and a drop-in filter cartridge removes 99.5 percent of particles of 0.3 µm and larger. The bright 3.5-digit, 0.5 inch red LED display remains readable in sunlight, and a 4 to 20 mA output on the side lets the unit drive a recorder or data-logger. Two interchangeable inlet and outlet fittings let the user swap between atmospheric and line-pressure sampling just by changing positions.
MDM50 key figures from the datasheet
| Part number | MDM50 |
| Sensor | SF82 polymer thick-film moisture sensor, field-replaceable |
| Measurement range | -60 to +20 °C (-76 to +68 °F) dew point |
| Accuracy | ±2 °C (±3.6 °F) dew point |
| Response | T95 to -60 °C dew point in under 3 minutes |
| Repeatability | 0.5 °C (0.9 °F) dew point |
| Calibration | 9-point certificate traceable to national standards |
| Output | 4 to 20 mA, 2-wire current source, user-configurable |
| Battery | rechargeable NiMH, 16 hours from full charge; universal charger supplied |
| Maximum pressure, low-pressure version | 2 MPag (20 barg / 290 psig) |
| Recommended flow | 1 to 5 Nl/min |
| Ingress protection | NEMA Type 6 with the case closed |
| Operating temperature | -20 to +50 °C; storage -20 to +60 °C |
| Weight and case | 4 kg; yellow polypropylene case |
| Electrical safety | EN 61010-1 |
How MDM50 differs from MDM50-HP and the replacement
The order-code sheet defines MDM50 as the base model with an SF82 sensor and a 20 barg limit, while MDM50-HP is a separate high-pressure code with an SF72 sensor. Within MDM50 itself, three features are selectable: units in degrees C or F, fittings (6 mm Legris push, 6 mm Swagelok or 1/4 inch Swagelok) and a battery charger for the UK, US, EU, CN or AU. The successor, Easidew PDP Dryer Portable, adds a touchscreen, internal pressure measurement, 2 GB logging and USB-C, so a buyer who only needs to keep an existing MDM50 running should keep the existing instrument and one who wants new functions should look at EA-PDP-A or EA-PDP-B.
Applications of MDM50 in industrial plants
In Oman and the GCC, an instrument of this size is carried by maintenance technicians auditing refrigerant and desiccant dryers, checking nitrogen or oxygen generators, and confirming that pneumatic lines on rolling stock or process skids are dry. It also helps on injection-moulding machines, where resin dryers need a low dew point, and on instrument-air headers feeding control valves and analyzers.
Sensor technology and calibration integrity in MDM50
MDM50 relies on advanced thick-film polymer moisture sensing coupled to a microprocessor circuit, packaged as an interchangeable sensor-transmitter module. Each module is characterised in a 9-point calibration against a fundamental reference hygrometer, and then quality tested so that sensors behave consistently before they are used in the field. The datasheet states that every instrument is supplied with a calibration certificate traceable to national standards (NPL and NIST) from Michell’s accredited laboratory. All calibration data lives in the sensor’s own memory, which is why a freshly calibrated module can simply be swapped in during a service visit and the instrument keeps its traceability without reprogramming.
Sampling system and pressure handling of MDM50
Unlike most hand-held meters, MDM50 has a full sampling system built in: a stainless-steel block, fixed orifices that set the flow, and the filter. Gas can be measured at atmospheric pressure or at line pressure by swapping the two interchangeable inlet and outlet fittings (1/8 inch BSPT threads). The datasheet quotes a 2 MPa (20 barg, 290 psig) limit for the low-pressure version with push-in fittings and tubing of 6 mm PTFE, and a recommended flow of 1 to 5 Nl/min. Do not exceed the pressure printed for the fittings that are installed, and always vent the outlet safely.
Spares and accessories for MDM50
The order codes list MDM50-BAT for the replacement battery pack and MDM50-CHA-UK, -US, -EU and -CH for chargers, alongside filter cartridges, guards, tubing and fittings that store inside the lid. The sensor module stores all its calibration data in its own memory, so on-site exchange can be done by untrained personnel, and the outer case carries a lifetime guarantee under the manufacturer’s terms.
Operating MDM50 correctly
Connect the sample gas to the quick-connect or Swagelok fittings, switch on and wait for the display to settle; the unit starts measuring automatically. Keep flow between 1 and 5 Nl/min, and use the outlet as a pigtail so that ambient moisture cannot diffuse back. If the readings look slow, replace the filter cartridge and check that the fittings are in the intended atmospheric or pressurised positions.
Documents and quotation
The datasheet for MDM50 is attached as a PDF. Because the product is obsolete, availability depends on stock and on repair channels, so please state in the RFQ the exact part number MDM50, the unit option required (units, fittings, charger), the quantity, and whether you need the whole instrument or only a spare such as MDM50-BAT.
Datasheets & Documents
- Datasheet Michell MDM50 Portable Hygrometer (Obsolete) Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell MDM50 Portable Hygrometer (Obsolete)
Answers from our engineering team on installation, compatibility and integration.
01Is MDM50 still in production?
No. The manufacturer's product page marks MDM50 obsolete, replaced by the Easidew PDP Dryer Portable, with a last-time-buy order date of 30 April 2024.
02What dew-point range does MDM50 cover?
MDM50 covers -60 to +20 °C (-76 to +68 °F) dew point with ±2 °C accuracy and T95 to -60 °C in under 3 minutes.
03What pressure is MDM50 rated for?
The base MDM50 code is listed for 20 barg maximum with its integral filter and flow control; a separate MDM50-HP code exists for high-pressure use.
04How long does the MDM50 battery run?
The rechargeable NiMH pack provides about 16 hours of operation from a full charge, and a universal battery charger is supplied.
05Which replacement parts are listed for MDM50?
The order codes include MDM50-BAT for the battery pack and chargers MDM50-CHA-UK, MDM50-CHA-US, MDM50-CHA-EU and MDM50-CHA-CH for the regional versions.