Brand:

Panametrics DigitalFlow GS868 Steam Mass Ultrasonic Flowmeter

Description

GS868: steam mass flow by ultrasound

The Panametrics DigitalFlow GS868 is a console-style ultrasonic flowmeter that measures the mass flow of saturated or superheated steam. Compact wetted transducers are installed in the pipe or duct, one upstream of the other, and they send and receive ultrasonic pulses through the steam. The meter works out the difference between upstream and downstream transit times, applies digital signal processing and correlation detection to find velocity and volumetric flow, and then combines the result with temperature and pressure inputs and built-in steam tables to give mass flow. Conventional steam meters impose a permanent pressure drop and have limited rangeability; the GS868 offers neither of those drawbacks.

GS868 features

  • Rangeability of 1500 to 1 and bidirectional velocity from minus 150 to plus 150 ft/s (minus 46 to plus 46 m/s).
  • Pipe sizes from 2 in to 48 in nominal bore (50 to 1200 mm).
  • One-channel standard; optional two-channel model for two paths on one pipe or one path on each of two pipes.
  • Mass flow, standard and actual volumetric flow, totalized flow and velocity, plus transit time and sound speed diagnostics.
  • Tolerance to dirty streams, no moving parts, and no lubrication or routine cleaning.
  • Dual-window graphic display with 39-key keypad, and PanaView PC software.

GS868 technical data

Item GS868
Accuracy 1% to 2% of reading typical; up to 0.5% achievable with process calibration
Repeatability 0.2% to 0.5% of reading
Straight run assumed 20 diameters upstream, 10 downstream; velocity above 3 ft/s (1 m/s)
Transducer temperature -190 to 450 C (-310 to 842 F)
Transducer pressure 0 to 2700 psig (187 bar) standard; 3480 psig (240 bar) optional
Transducer material and mounting Titanium or stainless steel; flanged port, spool piece or cold tap
Enclosure Epoxy aluminum Type 4X / IP66, FM/CSA Class I Div 2; options stainless steel, fiberglass, explosion-proof
Size and weight 14.24 x 11.4 x 5.12 in; 11 lb (5 kg)
Power 100 to 130 or 200 to 265 VAC; optional 12 to 28 VDC; 20 W
Standard I/O Two isolated 0/4 to 20 mA outputs, 550 ohm, NAMUR NE43
Optional boards Six slots: analog out, analog in, RTD in, totalizer/frequency, alarm relays
Digital interfaces RS232 standard; RS485, Modbus, Ethernet, OPC, Foundation Fieldbus optional
Data logging More than 43,000 points

Pressure loss compared with other steam meters

The datasheet quantifies the cost of conventional steam measurement. At 100 ft/s of saturated steam in a 4 in schedule 40 line at 40 psig, a vortex meter loses about 8.28 in of water column and an orifice plate 14.1 in, whereas the transit-time meter loses 0.05 in. In a 12 in schedule 160 line at 300 F, the vortex meter loses 186 in and the orifice plate 318 in, while the ultrasonic meter shows essentially no loss. On steam headers that serve turbines or process heaters, this saved pressure is real energy.

How GS868 differs from XGS868i and the FLI

The GS868 is the console version with two 64 by 128 graphic displays, six optional I/O slots and a 14 in tall wall-mount housing, driven by the 20 W supply. The newer XGS868i packs the electronics into a compact explosion-proof transmitter, and the PanaFlow FLI uses retractable insertion transducers with a 285 psig limit; the GS868 transducers go to 2700 psig and from minus 190 to 450 C, which is a much harsher envelope than the FLI limit of 300 C. Choose the GS868 where high pressure steam, a cabinet-style console and many I/O options are needed.

To pick the right channel count, remember what the optional second channel gives: on a single pipe, two paths at the same location average out profile effects and are the route to the best accuracy, while on two pipes a single console does the work of two meters at lower cost. The datasheet quotes 1 to 2 percent of reading as typical with accuracy depending on pipe size and whether one or two paths are used, and says that process calibration can reach 0.5 percent of reading. That makes the GS868 suitable both for plant-balance work, where trend and rangeability matter, and for steam sales or allocation, where the figure on the invoice is the figure that counts. Mass flow depends on pressure and temperature inputs, so pressure and temperature transmitters should be located close to the transducers and powered from the optional input boards, which supply 24 V loop power.

Connectivity is flexible as well. The console has an RS232 interface as standard and can be ordered with RS485, Modbus over RS485 or TCP, Ethernet, an OPC server or Foundation Fieldbus. Logged data of over 43,000 points can be reviewed on the display in graph form or downloaded to a PC with PanaView, which helps with commissioning, steam balance studies and root-cause analysis after a boiler trip.

Applications

The datasheet names HVAC, pneumatic power systems, food and beverage, water purification and distillation, chemical and petrochemical, electric power generation, steel and manufacturing, and public works. In Oman and across the GCC that includes steam headers at power and desalination plants, refinery steam balance and tracing circuits, and district heating supplied from central boilers. Mass flow supports boiler efficiency and steam cost allocation between users.

Installation and set-up

The system includes one or two pairs of transducers, preamplifiers and the console, which can sit up to 500 ft (150 m) from the transducers. Transducers are installed in a flowcell or directly into the pipe by cold tap. Enter pipe, steam and transducer data on the keypad or with PanaView, connect temperature and pressure inputs for mass flow, and set up outputs from the same interface. Use a two-channel layout when the best accuracy is wanted.

Supply information

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We can quote GS868 spares such as I/O boards, transducers and preamplifiers.

Documents and quotation

A manufacturer datasheet for GS868 is provided. Please send an RFQ listing GS868, channel count, pipe size, steam pressure and temperature, I/O boards, power option and quantity.

Other Models in the Panametrics Digitalflow Range

Seven Star LLC supplies models from the Panametrics Digitalflow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics DigitalFlow XMT868i Liquid Ultrasonic Flow TransmitterUltrasonic FlowmetersView details
Panametrics DigitalFlow XGS868i Steam Ultrasonic Flow TransmitterUltrasonic FlowmetersView details
Panametrics DigitalFlow GC868 Clamp-On Gas Ultrasonic FlowmeterUltrasonic FlowmetersView details
Panametrics DigitalFlow DF868 Liquid Ultrasonic FlowmeterUltrasonic FlowmetersView details
Panametrics DigitalFlow GS868 Steam Mass Ultrasonic FlowmeterUltrasonic FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Panametrics DigitalFlow GS868 Steam Mass Ultrasonic Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics DigitalFlow GS868 Steam Mass Ultrasonic

Answers from our engineering team on installation, compatibility and integration.

01What does the GS868 measure?
It measures the mass flow of saturated or superheated steam, along with standard and actual volumetric flow, totalized flow and velocity.
02What rangeability does GS868 offer?
The datasheet states a 1500 to 1 overall rangeability, with velocities from minus 150 to plus 150 ft/s in either direction.
03Does the GS868 cause a pressure drop?
Transducers do not obstruct the flow, so the datasheet shows about 0.05 in of water loss versus 8.28 in for a 4 in vortex meter in a comparable case.
04Can GS868 measure two pipes?
Yes. An optional two-channel model measures two paths on one pipe or one path on each of two pipes.
05What temperature and pressure can GS868 transducers withstand?
Minus 190 to 450 C and 0 to 2700 psig (187 bar) standard, with a 3480 psig (240 bar) option.