Brand:

Panametrics PanaFlare XGF1100 Multipath Flare Gas Ultrasonic Meter

Description

PanaFlare XGF1100 in brief

The Panametrics PanaFlare XGF1100 is described by the manufacturer as its most advanced flare gas ultrasonic transmitter, and it is the first in the range that can run up to four acoustic paths. Like earlier flare meters it uses Correlation Transit-Time measurement and a patented molecular weight calculation, but it adds built-in basic computational fluid dynamics correction, optional compressibility compensation, net heating value output and live combustion efficiency and destruction removal efficiency (CE/DRE) monitoring for unassisted flares. The XGF1100 is the model to look at when a site needs flare data that is close to fiscal quality and has to survive tightening emissions rules.

Feature list for the XGF1100

  • Velocity, volumetric flow, mass flow and molecular weight, plus net heating value output.
  • One to four path configurations; up to four channels by consultation with the factory.
  • Velocity to 120 m/s (394 ft/s), low flow down to 0.03 m/s (0.1 ft/s), turndown 4000 to 1.
  • Pipe diameters from 3 in to 130 in (80 mm to 3.25 m).
  • Built-in basic CFD to compensate for short straight runs, and cross-flow immunity in large pipes.
  • Compliance with API 22.3, tested and validated at a third-party calibration laboratory.
  • Nitrogen-purge tolerant at very low flow, relevant to zero routine flaring policies.

XGF1100 electrical and mechanical specifications

Item XGF1100 value
Measurement mode Patented correlation transit-time
Fluid Flare and vent gases; pipes of all metals and fiberglass
Housing Epoxy-coated copper-free aluminum Type 4X / IP66, optional stainless steel; Class I Div 2 configurable; explosion-proof Class I Div 1 Groups BCD, Ex d IIC, IECEx and ATEX II 2G
Size, weight 8.2 in x 6.6 in (208 x 168 mm), 10 lb (4.5 kg)
Display and keypad 128 x 64 monochrome LCD; built-in lockable magnetic six-button keypad
Power 100 to 240 VAC plus or minus 10%, optional 12 to 28 VDC; 15 W maximum
Ambient temperature -40 to 149 F (-40 to 65 C); -40 to 140 F with Foundation Fieldbus
Standard I/O One isolated digital output (alarm, pulse or frequency); one 4 to 20 mA output, 600 ohm, NAMUR NE43
Optional I/O Second digital output, two more 4 to 20 mA outputs, one or two 4-20 mA inputs, one or two 3-wire or 4-wire RTD inputs, 100 or 1000 ohm platinum
Digital interfaces RS485 Modbus and Ethernet 10/100 with PanaView Plus web server; optional HART 7 with four dynamic variables; optional Foundation Fieldbus FISCO
Transducers T5MAX, -55 to 150 C, -2 to 1500 psig, titanium, Hastelloy or SS316
Preamplifier In-line XAMP, gain 20 and 40 standard; 2 and 10 optional

How XGF1100 differs from XGF868i and GF868

The nearest sibling, the XGF868i, tops out at two channels and a 4 in to 120 in pipe range; the XGF1100 extends this to 3 in to 130 in and to up to four paths. Its power draw falls from 20 W to 15 W, the screen moves from a 2 by 16 character text display to a 128 by 64 pixel graphic LCD, and Ethernet with a built-in web server and RS485 Modbus become standard instead of options. On the analog side the XGF1100 has a single standard 4 to 20 mA output where the XGF868i has two, with additional outputs optional. Only the XGF1100 lists CE/DRE monitoring, built-in CFD and API 22.3 compliance.

Why multipath matters for flare accuracy

The manufacturer observes that flare gas measurement is drifting toward fiscal-style metering, so multipath layouts are requested for better accuracy, tolerance of non-ideal installations and redundancy. With four paths the meter can average out swirl and cross-flow that a single chord would misread. Standard mounting patterns remain diagonal 45, mid-radius 90, 90-180, off-diameter diagonal 45 and pipe-rack arrangements, and a six-degree recovery angle on the downstream transducer supports the highest flow rates.

Use cases in Oman and the GCC

Operators of LNG, refining, petrochemical and upstream plants in Oman face methane and flaring reporting. The XGF1100 helps by showing real flare mass flow at the very low base-load rates now common under zero routine flaring, and by tracking destruction removal efficiency where flares are unassisted. It also serves biogas and digester vent lines.

Installation and commissioning for XGF1100

Transducers and insertion mechanisms are installed in a flowcell or by hot or cold tapping, and the transmitter can be as far as 1,000 ft (300 m) away. During commissioning, confirm path count, enable the compressibility option if flare pressure is elevated, check RTD or 4 to 20 mA temperature and pressure inputs, and review the low-flow error behaviour with the factory when stack velocities are below 1 ft/s.

For the control system the practical gains are twofold. First, the web server on the Ethernet port means a technician with a laptop can view waveforms and diagnostics without installing software, and Modbus over RS485 is already present for the DCS or flow computer. Second, the optional HART 7 layer exposes four dynamic variables, so mass flow, velocity, molecular weight and heating value can be mapped to the host through a single loop. If the plant uses Foundation Fieldbus, the FISCO option is offered, but the datasheet lowers the maximum ambient to 140 F (60 C) for that variant, which should be checked against the stack-side shade temperature in Gulf summer conditions.

Maintenance

There are no moving parts, no tubes and no holes, so upkeep centres on diagnostics. The transducers are sealed metal and resist erosion and thermal cycling.

Ordering context

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Several XGF1100 features are marked consult factory in the datasheet, so we confirm the configuration with you first.

Documents and quotation

The manufacturer datasheet for XGF1100 is available here. Please send an RFQ stating XGF1100, number of paths, protocol, housing and certification, pipe size and quantity.

Other Models in the Panametrics Flare Range

Seven Star LLC supplies models from the Panametrics Flare range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics DigitalFlow XGF868i Flare Gas Ultrasonic FlowmeterUltrasonic FlowmetersView details
Panametrics PanaFlare XGF1100 Multipath Flare Gas Ultrasonic MeterUltrasonic FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Panametrics PanaFlare XGF1100 Multipath Flare Gas Ultrasonic Meter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics PanaFlare XGF1100 Multipath Flare Gas

Answers from our engineering team on installation, compatibility and integration.

01How many paths can the XGF1100 use?
It supports flexible one to four path configurations, making it the first Panametrics ultrasonic flare transmitter with up to four paths.
02Does the XGF1100 monitor combustion efficiency?
Yes. The datasheet lists live CE/DRE monitoring for unassisted flares plus a net heating value output, with details on consultation.
03What pipe size range does the XGF1100 cover?
From 3 in to 130 in (80 mm to 3.25 m) diameter, at velocities up to 120 m/s and down to 0.03 m/s.
04Is the XGF1100 compliant with a flare test protocol?
It is stated to comply with API 22.3, fully tested and validated through a third-party calibration laboratory.
05What communication options does the XGF1100 have?
RS485 Modbus and Ethernet 10/100 with the PanaView Plus web server as standard, and optional HART 7 or Foundation Fieldbus FISCO.