Brand:

Panametrics DigitalFlow XGF868i Flare Gas Ultrasonic Flowmeter

Description

XGF868i: the compact explosion-proof flare gas transmitter from Panametrics

Where the console-style GF868 is wall-mounted in a cabinet-sized enclosure, the Panametrics DigitalFlow XGF868i puts the whole electronics package in a compact explosion-proof, flame-proof transmitter head that is meant to sit close to the measuring point. That shortens the field wiring and removes the need for a separate safe-area shelter. The measuring principle is unchanged: patented Correlation Transit-Time, digital signal processing and a molecular weight algorithm that works from sound speed, so velocity, volumetric flow and mass flow are reported without needing the gas composition in advance. The XGF868i is supplied as a two-channel unit as standard.

What the XGF868i measures

  • Velocity, actual and standard volumetric flow, and mass flow of flare and vent gases.
  • Instantaneous average molecular weight, derived from sound speed and independent of the adiabatic constant gamma for hydrocarbon gases.
  • Optional net heating value of vent gas in BTU/SCF, MJ/m3 or kJ/m3.
  • Velocities from 0.1 to 328 ft/s (0.03 to 100 m/s) bidirectionally; extended range to 394 ft/s (120 m/s) one-way; turndown up to 4000 to 1.
  • Pipe sizes from 4 in to 120 in (100 mm to 3 m).

XGF868i specification summary

Parameter XGF868i data
Fluids Flare and vent gases
Pipe materials All metals and fiberglass; others on consultation
Channels Two as standard, for two-path averaging
Housing Epoxy-coated aluminum Type 4X / IP66, or stainless steel; explosion-proof Class I Div 1 Groups BCD, Ex d IIC T6 Gb, IECEx and ATEX II 2G
Size and weight 8.2 in x 6.6 in (208 x 168 mm); 10 lb (4.5 kg)
Display 2 line by 16 character backlit LCD, up to four parameters in sequence
Keypad Built-in magnetic six-button keypad
Supply 100 to 240 VAC, plus or minus 10%; optional 12 to 28 VDC; 20 W maximum
Standard I/O Two isolated 0/4 to 20 mA outputs, 600 ohm maximum; two 4 to 20 mA inputs with 24 VDC loop power, or one 4 to 20 mA input plus one three-wire 100 ohm platinum RTD input (-100 to 350 C)
Optional outputs Two optically isolated frequency outputs up to 10 kHz
Communications RS232 with PanaView software; HART 7 on the 4-20 mA output; optional Modbus, Ethernet, OPC, Foundation Fieldbus, Namur NE107
T5MAX transducers -55 to 150 C; -2 to 1500 psig; titanium, Hastelloy or SS316

How XGF868i differs from GF868 and XGF1100

Compared with the GF868, the XGF868i trades the two graphic LCDs, 39-key keypad and four optional I/O slots for a smaller 4.5 kg head with a 2 x 16 character display and magnetic buttons, and its minimum pipe diameter is 4 in rather than 2 in. Its housing weighs 10 lb versus 11 lb, and it draws up to 20 W in both cases. The datasheet also lists a dedicated low-flow performance chart for the XGF868i fitted with T17 transducers and a six-degree recovery angle on the downstream transducer that supports the high-flow capability, with NIST-traceable test results above 120 m/s. Choose the XGF868i when a field-mounted, explosion-proof transmitter is more useful than a cabinet console.

XGF868i path layouts and installation

Transducers and insertion mechanisms are supplied per channel and fitted in a flowcell or by hot or cold tapping. Standard mounting patterns shown include diagonal 45 degree, mid-radius, 90 and 90-180 arrangements, pipe-rack and off-diameter diagonal 45 layouts. A single long path is used for accurate low flow, and the two-channel layout gives cross-flow immunity in large pipes. The transmitter can be placed up to 1,000 ft (300 m) from the transducers, and the T5MAX transducers are designed for hazardous areas.

Oman and GCC flare applications for XGF868i

Refinery, petrochemical and upstream facilities in Oman use flare meters to track losses to the flare, close the plant mass balance and demonstrate emissions compliance. The XGF868i suits unit-level headers and offshore topsides where space is tight, and digester or biogas vent lines at wastewater plants. Sound speed and the diagnostic outputs allow verification of the meter while it measures, which helps with audits.

One practical point for control-room engineers: the XGF868i head is a small unit, so teams should plan cable entries, conduit seals and the sunshade or rack position at the design stage rather than leaving them to the commissioning crew. The magnetic six-button keypad lets a technician operate the meter without removing the explosion-proof cover, which matters when a permit to open the enclosure would otherwise be required in a classified area. The two 0/4 to 20 mA outputs can be assigned, for instance, to mass flow and molecular weight so that both appear in the DCS, while the HART 7 layer on the current loop carries diagnostics for asset management without an extra cable.

Commissioning checklist for XGF868i

Confirm pipe inner diameter and wall, transducer path geometry, gas range, and the temperature and pressure sources. Wire the two 4 to 20 mA outputs, decide whether the second input is a pressure transmitter or an RTD, enable HART if the DCS needs it, and use PanaView over RS232 for the initial setup. After configuration, compare sound speed against the expected range for the gas and review the signal quality indicators before declaring the meter in service.

Servicing the XGF868i

No moving parts and no tubes or holes mean there is little to clog. The special sealed metal transducers resist erosion and thermal-cycling stress; service is mostly periodic checks of diagnostics and verification of temperature and pressure inputs.

Supply information

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We can discuss XGF868i configuration, spares and replacement parts for installed flare meters.

Documents and quotation

The manufacturer datasheet for XGF868i is provided. Send your RFQ with the XGF868i part number, channel count, housing and certification needs, communication protocol and quantity.

Other Models in the Panametrics Flare Range

Seven Star LLC supplies models from the Panametrics Flare range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics DigitalFlow XGF868i Flare Gas Ultrasonic FlowmeterUltrasonic FlowmetersYou are viewing this model
Panametrics PanaFlare XGF1100 Multipath Flare Gas Ultrasonic MeterUltrasonic FlowmetersView details
Datasheets & Documents
  • PDF Datasheet Panametrics DigitalFlow XGF868i Flare Gas Ultrasonic Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics DigitalFlow XGF868i Flare Gas

Answers from our engineering team on installation, compatibility and integration.

01What makes the XGF868i different from the GF868?
The XGF868i packs the electronics into a compact explosion-proof transmitter weighing 4.5 kg with a 2 by 16 character display, rather than a wall-mounted console with graphic displays.
02Is the XGF868i single or dual channel?
The datasheet lists two channels as standard, supporting two-path averaging or single-channel operation in different transducer layouts.
03What pipe sizes does the XGF868i cover?
Pipe diameters from 4 in to 120 in (100 mm to 3 m), with velocities to 394 ft/s in the extended-range version.
04Which hazardous-area approvals does the XGF868i list?
Explosion-proof Class I Division 1 Groups BCD for NEC and CEC, and Ex d IIC T6 Gb under IECEx and ATEX II 2G.
05Which digital interfaces are available on the XGF868i?
RS232 with PanaView as standard, HART 7 on the 4-20 mA output, and optional Modbus, Ethernet, OPC and Foundation Fieldbus.