Brand: SMC
SMC VXP2390-20-1G 2-Port Solenoid Valve, Rc 2, 100 VAC
Description
SMC VXP2390-20-1G VXP pilot operated 2-port solenoid valve, Rc 2
The SMC VXP2390-20-1G is a pilot operated, normally closed 2-port solenoid valve from the VXP21/22/23 series. It is designed to control air, gas, steam, water and oil, with the body in brass (C37 or CAC408) and the standard seal in NBR; other seals and stainless steel bodies are chosen through the option symbol in the part number. The SMC VXP2390-20-1G version has a Rc 2 thread connection, an orifice of 50 mm, a 100 VAC 50/60 Hz coil and a grommet electrical entry.
As a pilot operated valve, the VXP2390-20-1G uses the line pressure to help open the main seat once the pilot is opened by the solenoid. This allows a large orifice to be switched by a relatively small coil, but it also means that a minimum operating pressure differential is required: for this size it is 0.03 MPa. Below that differential the valve may not open fully, so the valve is not suited to vacuum or zero-differential service.
The VXP series is common on water supply lines, compressed air headers, lubrication circuits, boiler feed and utility distribution. Maintenance teams searching for the VXP2390-20-1G are usually replacing a valve on an existing skid, so the complete code, including the voltage and the electrical entry, should be checked before ordering.
Key features of the VXP2390-20-1G
- Pilot operated, normally closed construction with a 50 mm orifice and a Rc 2 thread connection.
- Maximum operating pressure differential: 1.0 MPa for water, 1.0 MPa for air, 0.7 MPa for oil and 1.0 MPa for steam with the AC coil types (see the catalog table); minimum operating differential 0.03 MPa.
- Flow factor Kv 43, converted Cv 49 and effective area 880 mm squared for the VXP2390-20-1G size.
- 100 VAC 50/60 Hz coil; allowable voltage fluctuation plus or minus 10 percent of the rated value.
- Wide choice of options: seal materials NBR, FKM, EPDM and PTFE, body materials C37 or CAC408 and stainless steel, and coil classes B and H.
- Maximum system pressure of 1.5 MPa for water, air and oil and 1.0 MPa for steam, as listed in the catalog.
- Electrical entry and options: grommet, conduit, DIN terminal or conduit terminal entries with surge voltage suppressor or indicator light options in the series; this variant uses the grommet entry (G).
- Weight of approximately 5400 g for the grommet type.
VXP2390-20-1G technical specifications
The table below lists the values the manufacturer publishes for the VXP2390-20-1G and its series. Always confirm the final configuration against the datasheet before ordering.
| Parameter | Value |
|---|---|
| Series | VXP21/22/23 pilot operated 2-port solenoid valve |
| Part number | VXP2390-20-1G |
| Valve type | Normally closed, single unit, pilot operated |
| Connection | Rc 2 |
| Orifice diameter | 50 mm |
| Min. operating pressure differential | 0.03 MPa |
| Max. operating pressure differential (water, air) | 1.0 MPa |
| Max. operating pressure differential (oil) | 0.7 MPa |
| Max. system pressure | 1.5 MPa (water, air, oil); 1.0 MPa (steam) |
| Flow factor Kv / Cv | 43 / 49 |
| Effective area | 880 mm squared |
| Body material | Brass (C37 or CAC408) in the standard construction |
| Seal material | NBR (standard) |
| Rated voltage | 100 VAC 50/60 Hz |
| Allowable voltage fluctuation | Plus or minus 10 percent |
| Coil power | AC: 50 VA inrush and 21 VA holding at 50 Hz, 45 VA inrush and 17 VA holding at 60 Hz |
| Fluid temperature, water (standard) | 1 to 60 C |
| Fluid temperature, air (standard) | Minus 10 to 80 C (dew point minus 10 C or less) |
| Fluid temperature, oil (standard) | Minus 5 to 60 C (50 mm squared per second or less) |
| Ambient temperature | Minus 10 to 60 C |
| Weight (grommet type) | 5400 g |
Typical applications in Oman and the GCC
In oil and gas and petrochemical sites in Oman and the GCC, the VXP2390-20-1G can be used on utility water, instrument and plant air, lube oil and cooling lines, where a robust brass valve with a standard pilot operated design is sufficient. It is frequently used as an on/off isolation valve on skids, filling lines and wash-down circuits.
In water and wastewater plants, desalination auxiliaries and district cooling, the VXP2390-20-1G provides remote on/off control with a conventional solenoid. In manufacturing, food-grade utility and workshop installations, it controls water and air supply to machines. For steam, high temperature water or special oils, choose the matching option symbol instead of the standard code; the VXP2390-20-1G is the standard NBR type.
Pilot operated solenoid valves such as the VXP series are chosen when a large flow must be switched with low coil power. A small pilot port is opened by the solenoid; the resulting pressure imbalance across a diaphragm or piston lifts the main seat. Because the valve relies on the line pressure, it should be installed in the correct flow direction with enough upstream pressure for reliable opening, and it should be protected from particles that could block the pilot hole.
Selection of the seal material is the most important decision after size. NBR is the common standard for water, air and general oil. FKM suits many oils and higher temperatures, EPDM suits hot water and steam condensate, and PTFE-based seals suit aggressive media. SMC publishes a fluid check list for these choices, and we encourage buyers to consult it when the medium is not plain water or air.
In regions with hard water or desert dust, a strainer upstream of the valve extends service life significantly. Sizing the strainer for the flow and cleaning it on a schedule is a low-cost way to prevent valve sticking and coil burnout caused by a valve that does not complete its stroke.
Selection and compatibility notes for the VXP2390-20-1G
Check the fluid first. The VXP2390-20-1G is the standard construction for water, air and turbine oil. If you need steam or high temperature service, the series offers different option symbols for the seal and coil class, and these change the part number. A mismatch of seal and fluid is a common cause of early valve failure.
Check the pressure differential. The VXP2390-20-1G needs at least 0.03 MPa across the valve to open reliably and is rated for a maximum differential of 1.0 MPa on water and air and 0.7 MPa on oil. If the line pressure is lower than the minimum, a direct operated valve is a better choice.
Check the electrical side. The VXP2390-20-1G carries a 100 VAC 50/60 Hz coil, and a coil of another voltage requires a different part number. The grommet entry gives a short lead wire; if the installation needs a conduit or a DIN connector, select the matching entry code instead.
Reading the part number
- VXP2: pilot operated 2-port solenoid valve series; 2390: model and body size code (50 mm orifice).
- The first part of the code identifies the normally closed single unit construction with the standard option (no option symbol).
- 20: connection code, Rc 2.
- 1: rated voltage 100 VAC 50/60 Hz.
- G: grommet electrical entry, with no electrical option, bracket or special thread suffix.
Installation and commissioning of the VXP2390-20-1G
Install the VXP2390-20-1G with the flow direction indicated on the body, with the coil above the pipe where possible, and use a strainer or filter upstream. Do not over-tighten the threaded connection, apply sealant only to the male thread and keep it away from the port opening, and support the pipework so that its weight is not carried by the valve body.
Connect the coil to a 100 VAC 50/60 Hz supply within the allowable voltage range and make sure the grommet lead is protected from mechanical damage. Before putting the line in service, energize the valve, check that it opens and closes with the line pressure applied, and check for leakage at the connection. Always isolate and depressurize the line before removing the VXP2390-20-1G.
Maintenance and service life
Inspect the VXP2390-20-1G periodically for external leakage, coil temperature and unusual noise. A buzzing coil often means that the minimum differential is not reached or the voltage is too low. Keep the strainer clean, and operate the valve on a schedule if it stays in one position for long periods.
The coil and the internal seals are the parts most likely to need replacement. Record the full VXP2390-20-1G code with the installation date so that spares can be matched correctly in the future.
Related products and ordering notes
Other sizes of the VXP2 series use the same code structure, from Rc 1/4 to Rc 2 and flange types from 32A to 50A, with the same options for voltage, entry and seal. If your nameplate carries a code with extra letters after VXP2390-20-1G, such as an option symbol or the bracket suffix, include it in your RFQ. The VXP series is also available in a normally open version with its own part numbers.
SMC VXP2390-20-1G vs Other SMC 2-Port Solenoid Valve Rc 100 Variants
The SMC VXP2390-20-1G is the choice when your application specifically needs VXP2390-20-1G 2. Ordering a neighbouring size or rating in this family is the most common cause of returns, so compare the figure on the existing unit or the design data sheet before you send an RFQ.
| Variant | Distinguishing detail |
|---|---|
| SMC VXP2260-10-1G 2-Port Solenoid Valve, Rc 1, 100 VAC | VXP2260-10-1G 1 |
| SMC VXP2390-20-1G 2-Port Solenoid Valve, Rc 2, 100 VAC (this page) | VXP2390-20-1G 2 |
Frequently asked questions about the VXP2390-20-1G
- What does the VXP2390-20-1G control? The VXP2390-20-1G is a pilot operated normally closed 2-port solenoid valve for air, gas, water and oil in its standard NBR construction.
- What coil voltage does the VXP2390-20-1G use? The VXP2390-20-1G uses a 100 VAC 50/60 Hz coil, with an allowable voltage fluctuation of plus or minus 10 percent.
- What minimum pressure differential does the VXP2390-20-1G need? The VXP2390-20-1G needs at least 0.03 MPa of pressure differential to open reliably because it is a pilot operated valve.
- What is the connection size of the VXP2390-20-1G? The VXP2390-20-1G has a Rc 2 threaded connection and an orifice of 50 mm.
- How do I request a quotation for the VXP2390-20-1G? Send an RFQ to Seven Star LLC with the part number VXP2390-20-1G, the quantity and your delivery location, and our team will confirm availability and lead time.
Documents and quotation
The manufacturer catalog covering the VXP2390-20-1G is available as a datasheet download on this page, and it is the document to check for dimensions, wiring and option codes. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To receive a quotation, send the RFQ with the part number VXP2390-20-1G, the quantity, the required voltage or signal, the connection standard and your delivery location in Oman or the GCC. Our team will confirm availability and lead time for the VXP2390-20-1G and reply with a formal offer.
Other Models in the VXP2000 Range
Seven Star LLC supplies models from the VXP2000 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| SMC VXP2260-10-1G 2-Port Solenoid Valve, Rc 1, 100 VAC | Solenoid Valves | View details |
| SMC VXP2270-12-1G 2-Port Solenoid Valve, Rc 1 1/4, 100 VAC | Solenoid Valves | View details |
| SMC VXP2380-14-1G 2-Port Solenoid Valve, Rc 1 1/2, 100 VAC | Solenoid Valves | View details |
| SMC VXP2390-20-1G 2-Port Solenoid Valve, Rc 2, 100 VAC | Solenoid Valves | You are viewing this model |
Datasheets & Documents
- Datasheet SMC VXP2390-20-1G Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SMC is the Japanese specialist in pneumatic automation: air preparation units, solenoid valves, cylinders, fittings, process valves and sensors. Yoshiyuki Takada founded the company in Tokyo on 27 April 1959 as Shoketsu Kinzoku Kogyo, which means Sintered Metal Corporation, and its first products were sintered metal filters. SMC Corporation is headquartered in Tokyo and listed on the Tokyo Stock Exchange, and its products are used on machines and instrument air lines across the world.
Seven Star LLC, an independent supplier in Oman, lists SMC AW series filter regulators (AW20 and AW40) and the VX2 series direct-operated 2-port solenoid valve, and sources other SMC parts by full part number.
SMC company profile
| Founded | 27 April 1959, Tokyo, Japan, as Shoketsu Kinzoku Kogyo (Sintered Metal Corporation) |
|---|---|
| Founder | Yoshiyuki Takada (1928–2024) |
| First products | Sintered metal filters; pneumatic air line equipment from 1961 |
| Headquarters | Tokyo, Japan |
| Ownership | SMC Corporation, a public company listed on the Tokyo Stock Exchange |
| Product families | AF/AR/AW modular air preparation, VT/VQ/SY solenoid valves, VX/VXZ 2-port valves, air cylinders and rotary actuators, fittings and tubing, pressure and flow switches, vacuum equipment |
Milestones
- 1959: Shoketsu Kinzoku Kogyo is founded in Tokyo on 27 April and starts making sintered metal filters.
- 1961: Pneumatic air line equipment is added.
- 1964: Automatic control equipment becomes part of the business.
- 1967: The first overseas operation starts, with a stake in an Australian company.
- 1970: SMC begins making air cylinders.
SMC series listed on this page
The AW is a combined filter and pressure regulator in SMC's modular air preparation line. The body size is in the name: AW20 is the smaller unit and AW40 the larger, and the digits after the dash give the port size. A part number such as AW40-04-A therefore describes body size, port and options in one string. The VX2 is a direct-operated two-port solenoid valve for shutting off air, water, oil or steam, depending on the body and seal materials chosen.
SMC products we list
Ordering SMC parts: what we need
Give the complete SMC part number from the label, including thread prefix, options and the final suffix letter. For AW units state gauge, drain type and bracket if you need them. For VX2 valves send coil voltage, port size, orifice, body and seal material, and the fluid. Buyers in the GCC often have NPT or G threads on site, so say which thread standard the piping uses.
Facts checked against SMC's published corporate history, October 2026.
Browse SMC products by category: Regulators, Solenoid Valve.
FAQ
Questions about the SMC VXP2390-20-1G 2-Port Solenoid Valve, Rc 2, 100
Answers from our engineering team on installation, compatibility and integration.
01What does the VXP2390-20-1G control?
The VXP2390-20-1G is a pilot operated normally closed 2-port solenoid valve for air, gas, water and oil in its standard NBR construction.
02What coil voltage does the VXP2390-20-1G use?
The VXP2390-20-1G uses a 100 VAC 50/60 Hz coil, with an allowable voltage fluctuation of plus or minus 10 percent.
03What minimum pressure differential does the VXP2390-20-1G need?
The VXP2390-20-1G needs at least 0.03 MPa of pressure differential to open reliably because it is a pilot operated valve.
04What is the connection size of the VXP2390-20-1G?
The VXP2390-20-1G has a Rc 2 threaded connection and an orifice of 50 mm.
05How do I request a quotation for the VXP2390-20-1G?
Send an RFQ to Seven Star LLC with the part number VXP2390-20-1G, the quantity and your delivery location, and our team will confirm availability and lead time.