Groundwater supplies farms, villages, camps, factories and construction sites across Oman, and almost every well is equipped with a submersible pump and motor hanging on a riser pipe. A correctly sized borehole pump delivers the required flow at the required pressure for many years. An oversized or undersized unit can overpump the well, draw in sand, overheat the motor or burn out the cable. This guide explains the calculation step by step: total dynamic head, well yield, setting depth, motor cooling, cable sizing and protection, with a worked example.
What Makes Borehole Pump Sizing Different
A surface centrifugal pump sees a fixed suction level, but a well pump works against a water level that moves. When pumping starts, the water level in the well falls from the static level to a lower dynamic level, and the size of this drawdown depends on the flow rate and the aquifer. The pump and motor are also installed in a narrow casing, cooled only by the water flowing past them, and supplied through a long cable. Sizing therefore depends on the well test data, the casing diameter and the electrical supply, not only on the duty point. The principles of reading curves and staying near the best efficiency point are covered in our guide to centrifugal pump selection.
Step 1: Know the Well
Before choosing any borehole pump, collect the drilling and test pumping report. The key data are:
- Casing inner diameter: a 4 inch pump needs at least about 100 mm clear bore, a 6 inch pump about 150 mm, and an 8 inch pump about 200 mm.
- Total well depth and the position of the screens or perforated sections.
- Static water level measured from the ground before pumping.
- Dynamic water level and drawdown at the test flow rate, ideally from a step test at several flows.
- Safe yield recommended by the hydrogeologist, which is usually lower than the maximum test flow.
- Water quality: salinity, chloride, temperature, sand content and any hydrogen sulphide or iron.
As a rule, design the pump for no more than the safe yield. Pumping harder than the aquifer can supply lowers the water level until the pump runs dry or pulls sand through the screen, which shortens the life of both the well and the pump.
Step 2: Calculate Total Dynamic Head
Total dynamic head (TDH) is the energy the pump must add to the water, expressed in metres of water column. It is the sum of four parts:
| Component | What it includes | How to estimate |
|---|---|---|
| Dynamic water level | Static level plus drawdown at the design flow | From the step test; add a margin for seasonal decline |
| Elevation above ground | Height from wellhead to the highest discharge point or tank inlet | From site levels |
| Friction losses | Riser pipe, fittings, check valves, meter and delivery pipeline | Pipe friction tables or software at the design flow |
| Required outlet pressure | Pressure needed at the tank, irrigation system or network | 1 bar is about 10.2 m of head |
Friction in the riser pipe is often underestimated. A small riser saves cost but increases velocity and losses; for most designs, keep velocity in the riser between about 1 and 2.5 m/s. In deep wells and long pipelines, friction can add 10 to 20 percent to the head, so it is worth calculating rather than guessing.
Step 3: Select the Pump on its Curve
Submersible pumps are multistage: each stage adds a part of the head, and the number of stages is chosen to reach the TDH. Plot the system curve on the manufacturer curve and choose a model whose duty point lies close to the best efficiency point at the design flow. Check the head at minimum and maximum water levels, because the duty point moves as the water level changes over the seasons. Avoid selecting a pump that would run far to the right of its curve when the well level is high, which can overload the motor and cause upthrust.
Step 4: Size the Motor
The shaft power is calculated from P = (flow in m3/s x TDH in m x 9.81 x density) / pump efficiency. Choose a motor with a rating above the maximum power on the pump curve over the operating range, not just at the duty point. Submersible motors are rated for a maximum water temperature, often 30 to 35 C at full load. In wells with warm water, which is common in some Omani aquifers, the motor must be derated or a larger motor selected, according to the manufacturer tables.
Step 5: Motor Cooling and Flow Sleeves
A submersible motor relies on water flowing along its outer surface to remove heat. Manufacturers specify a minimum flow velocity past the motor, typically between about 0.08 and 0.15 m/s depending on the motor size and type. If the pump is installed in a large casing, below the screens, or in an open tank or reservoir, the water may not pass the motor fast enough. In those cases fit a flow sleeve, also called a cooling shroud, around the motor so that all the water entering the pump flows past it first. Running a motor without sufficient cooling is one of the most common causes of early winding failure.
Step 6: Decide the Setting Depth
Install the pump below the lowest expected dynamic water level, with a submergence margin of several metres so the intake never draws air or vortices. Where possible, set the pump above the screened section so water flows down past the motor and cools it. If the pump must sit inside or below the screens, use a flow sleeve. Never rest the motor on the bottom of the well, where sediment collects, and keep a clear space between the motor base and the well bottom.
Step 7: Size the Drop Cable
The cable runs from the motor to the starter panel and may be hundreds of metres long. It must be a submersible drop cable rated for continuous immersion, and its cross section must keep the voltage drop at full load current within the limit set by the motor manufacturer, commonly 3 to 5 percent. A long cable that is too small reduces the voltage at the motor, which increases current and temperature and can prevent the motor from starting.
- Cable length is the setting depth plus the distance from the wellhead to the panel.
- Use the full load current and the starting method when checking voltage drop.
- Make the motor lead joint with an approved resin or heat shrink splice kit and test the insulation before lowering the pump.
- Strap the cable to the riser pipe every few metres and leave slack for pipe stretch.
An insulation resistance test of the motor and cable before installation, and periodically afterwards, gives early warning of water ingress or cable damage.
Starting, Control and Protection
Small single phase motors are usually started direct on line through a control box with capacitors. Larger three phase motors can be started direct on line, with a soft starter or with a variable frequency drive. Submersible motors need to reach speed quickly, so ramp times are kept short, and a VFD should not run the motor below the minimum frequency recommended by the manufacturer, often around 30 Hz, to keep the thrust bearing lubricated and the motor cooled. See our comparison of soft starters and VFDs and our guide to VFD selection for hot climates for drive sizing and derating.
- Dry running protection by low level electrodes, a level transmitter or power monitoring.
- Overload, phase loss, phase imbalance and under or over voltage protection.
- Surge arresters at the panel and, in lightning prone areas, at the wellhead.
- A check valve at the pump outlet, with additional check valves in deep settings as the manufacturer recommends.
- A flow meter and pressure gauge at the wellhead to monitor performance and well yield.
A submersible level transmitter in the well shows the real dynamic level and helps protect the aquifer. Our submersible level transmitter guide explains installation in wells and boreholes.
Materials, Sand and Water Quality
Standard submersible pumps are made of AISI 304 stainless steel and suit fresh water. Brackish and saline groundwater, common near the coast and in many inland aquifers in Oman, needs AISI 316 or higher grades such as 904L or duplex, and in some cases a zinc anode or cathodic protection. Sand wears impellers, diffusers and bearings; manufacturers state a maximum sand content, and sand resistant designs with floating impellers and hard bearings are available for wells that cannot be fully developed. Water with iron or hydrogen sulphide may need special materials and cable sheaths.
Worked Borehole Pump Sizing Example
A farm needs 10 m3/h delivered to a tank 8 m above the wellhead, with 1 bar at the tank inlet. The well has a 150 mm casing, a static level of 40 m and a drawdown of 15 m at 10 m3/h from the test pumping report.
| Item | Value |
|---|---|
| Dynamic water level | 40 + 15 = 55 m |
| Elevation to tank | 8 m |
| Friction in riser, fittings and 200 m pipeline | About 7 m |
| Required outlet pressure | 1 bar = about 10 m |
| Total dynamic head | About 80 m |
| Hydraulic power | 1000 x 9.81 x 0.00278 x 80 = about 2.2 kW |
| Shaft power at 65 percent efficiency | About 3.4 kW |
| Motor selected | 4 kW three phase, checked for water temperature |
| Setting depth | About 65 m, above the screens, with 10 m submergence |
The next steps would be to confirm that a 4 inch pump with the right number of stages fits the 150 mm casing, check the cooling velocity past a 4 inch motor in a 150 mm casing, and calculate the drop cable size for roughly 90 m of cable plus the run to the panel.
Common Borehole Pump Sizing Mistakes
- Using the static level instead of the dynamic level in the head calculation.
- Choosing a pump for more flow than the well can supply, causing drawdown to the intake.
- Ignoring friction in long delivery pipelines and small risers.
- Selecting a motor for the duty point only, so it overloads when the water level is high.
- Undersized cable, giving low voltage and overheating at the motor.
- No flow sleeve when the pump is installed below the screens or in a tank.
- Standard 304 stainless steel in saline or high chloride groundwater.
Solar and Off-Grid Pumping
Many remote wells in Oman are far from the grid. Solar pumping systems use a variable speed motor and controller supplied by photovoltaic panels, sometimes with a generator backup. The pump delivers more water at midday and less in the morning and evening, so the design is based on daily water volume rather than a single flow rate, and a storage tank covers the night. The head calculation is the same, but the pump must operate efficiently across a range of speeds.
Borehole Pump Selection Checklist
| Data needed | Why it matters |
|---|---|
| Casing diameter and well depth | Defines the pump and motor size that will fit |
| Static level, drawdown and safe yield | Sets the design flow and the dynamic level |
| Discharge elevation, pipeline and outlet pressure | Completes the total dynamic head |
| Water temperature, salinity and sand content | Decides materials and motor derating |
| Power supply voltage, phase and distance to panel | Decides the motor type and cable size |
| Control method: DOL, soft starter, VFD or solar | Affects protection and minimum speed |
Submersible Pumps and Accessories from Our Catalog
The table below lists well pumps, drives, valves and instruments from our catalog that are used in groundwater pumping systems.
| Product | Type | Typical use |
|---|---|---|
| Grundfos SP | Multistage submersible pump | Water supply, irrigation and dewatering |
| Caprari E6NVX and E8NVX | 6 and 8 inch stainless submersible pumps | Municipal and agricultural wells |
| Caprari Desert E4X and E6X | Sand resistant submersible pumps | Wells with sand content |
| Pedrollo 6SR | 6 inch submersible pump | Irrigation and water supply |
| Pedrollo 4SR | 4 inch submersible pump | Domestic and farm wells |
| DAB S4 8/9 | 4 inch submersible pump 1.5 kW | Small water supply wells |
| DAB MICRA 100 M | 3 inch multi-impeller pump | Narrow wells and tanks |
| ABB ACQ580 | Water and wastewater drive | Variable speed pump control |
| Cla-Val 61-02 | Deep well pump control valve | Surge control at pump start and stop |
| Cla-Val 81-02 | No-slam hydraulic check valve | Pump discharge lines |
| Mobrey 9710 | Submersible hydrostatic level transmitter | Well level monitoring |
| Druck PDCR 1800 / PTX 1800 | Titanium submersible level sensor | Saline and aggressive groundwater |
| Kamstrup flowIQ 3200 | Ultrasonic water meter | Well abstraction metering |
Browse more in our submersible, borehole and wastewater pumps category. To get a quotation, send the well data, flow, total head, water quality, power supply and quantity through our quote request form or to [email protected].
Sourcing Submersible Pumps in Oman Through Seven Star LLC
Seven Star LLC is an independent supplier in Oman of submersible well pumps, motors, drives, check valves, level transmitters and water meters for farms, municipal supply, construction dewatering and industrial projects. We quote products from manufacturers such as Grundfos, Caprari, Pedrollo, DAB, ABB, Cla-Val, Emerson, Druck and Kamstrup. For each borehole pump enquiry, the model, materials, motor rating and lead time are confirmed against the manufacturer data at quotation.
Frequently asked questions
How do I calculate the total dynamic head for a well pump?
Add the dynamic water level (static level plus drawdown), the elevation from the wellhead to the discharge point, the friction losses in the riser and pipeline, and the required outlet pressure converted to metres of head.
What is the difference between static and dynamic water level?
The static level is the water level in the well when the pump is off. The dynamic level is the lower level reached while pumping at a given flow. The difference is the drawdown.
Why does a submersible motor need a cooling sleeve?
The motor is cooled by water flowing past it. If the pump is installed below the screens, in a wide casing or in a tank, the flow past the motor may be too slow, so a sleeve forces the water to pass the motor before entering the pump.
How do I size the cable for a submersible pump?
Choose a submersible drop cable whose cross section keeps the voltage drop within the motor manufacturer limit, usually 3 to 5 percent at full load, for the total length from motor to panel and the starting method used.
Which pump material is best for saline groundwater?
For brackish or saline water, AISI 316, 904L or duplex stainless steel pumps and motors are preferred over standard AISI 304, which can suffer pitting and crevice corrosion.
Who supplies submersible well pumps in Oman?
Seven Star LLC is an independent supplier in Oman that quotes submersible well pumps, drives, valves and instruments from leading manufacturers. Send your requirements through the quote request form or to [email protected].