Brand:

HOPPECKE grid | Xtreme VR 121500 FT Front Terminal Battery 12 V

Description

grid | Xtreme VR 121500 FT is the 12 V front-terminal block of the HOPPECKE grid | Xtreme VR green series, a pure lead AGM battery with an ABS-PC case. The green series data sheet lists 150 Ah at C10, 154 Ah at C8 and a footprint of 563 x 110 mm with 307 mm height, weighing about 48.7 kg.

A front-terminal pure lead block for cabinets with front access only

FT means real front terminals: cables and links are fitted on the front face, no extra connectors are needed, and the 110 mm width keeps the footprint narrow. The data sheet stresses ease of installation and maintenance. The 121500 FT is the middle size of the six FT types, between 121000 FT (94 Ah) and 122000 FT (196 Ah).

The green series flyer sets it beside the standard (pure) Xtreme VR and shows what changes: a front-terminal-only design, a narrower temperature window and a shorter life at 30 °C. Both use thin-plate pure lead technology with ESS electrolyte-stratification protection for frequent cycling.

Features stated in the green series data sheet

  • Pure lead grid electrodes (99.98 percent purity) with microporous glass fibre separators and ESS technology.
  • Operating range -35 °C to +50 °C, 15 years design life, Very Long Life class (over 12 years) per Eurobat Guide 2015.
  • Designed to be compliant with IEC 60896-21/22; UL recognized; UL94 V-0 halogen-free ABS-PC case.
  • Storage time up to 2 years; no refilling of distilled water; classified non-spillable and non-hazardous for ADR/RID, IMDG and IATA transport.

Technical specification

Specification of grid | Xtreme VR 121500 FT (green series data sheet)

Parameter Specification
Type grid | Xtreme VR 121500 FT, front terminal (Fig. B)
Nominal voltage 12 V block
Capacity C10 to 1.80 V per cell at 20 °C 150 Ah
Capacity C8 to 1.75 V per cell at 25 °C 154 Ah
Capacity C3 to 1.70 V per cell at 25 °C 140 Ah
Capacity C1 to 1.70 V per cell at 25 °C 118 Ah
Length x width x height 563 x 110 x 307 mm
Weight about 48.7 kg
Terminal M8 female; terminal screw torque 15 Nm (133 lbf in)
Recommended float voltage 2.3 V per cell at 20 °C, 2.288 V at 25 °C
Operating temperature -35 °C to +50 °C
Case material ABS-PC, UL94 V-0, halogen-free
Design life 15 years at 20 °C; Eurobat Very Long Life

Green series against standard Xtreme VR (flyer figures)

Parameter Specification
Design life at 30 °C 8 years (green series) against 10 years (standard)
Cycles at 30 / 50 / 70 percent depth of discharge 2330 / 1300 / 780 against 2800 / 1500 / 940
Energy density E10 to 1.80 V per cell at 20 °C at least 93 Wh per litre against at least 95
Charging current 5 to 40 A per 100 Ah, boost 2.40 V per cell

Selecting between the green series FT types and the top-terminal blocks

The same data sheet lists FT types 121000 FT 19 inch (94 Ah, 404 x 110 x 264 mm), 121000 FT 23 inch (103 Ah), 121500 FT (150 Ah), 121700 FT (165 Ah), 121900 FT (185 Ah, 563 x 125 x 307 mm) and 122000 FT (196 Ah, 60.0 kg), plus top-terminal blocks 122900 to 126000 (86 to 176 Ah).

Compare the C1 and C3 figures when the string must hold a load for minutes only. Where the room is hot or runtime must last, the standard series offers the wider range, so confirm the exact code and terminal version before ordering.

Installation and charging points from the manual

Check open-circuit voltage before connection: 12.78 V to 13.08 V per block at 20 °C, with no more than 0.05 V between blocks. Tighten terminal screws to 15 Nm plus or minus 1 Nm and use isolated connectors.

Float at 2.30 V per cell plus or minus 1 percent. New systems show wider voltage spreads that normally settle after about 6 months of standby parallel operation, so an equalizing charge is not the first response. Commissioning uses at most 2.4 V per cell and 20 A per 100 Ah.

Where front-terminal AGM blocks fit in the Gulf

The product page lists UPS and data centre, fossil power plants, telecommunication, oil and gas, emergency lighting and railway infrastructure among grid applications. General engineering note: in Gulf telecom shelters and compact UPS cabinets, front access matters wherever cabinet rows leave no top or rear access.

Related HOPPECKE items

The standard grid | Xtreme VR 12-150 is the top-terminal option and the grid | XtremeStack carries top-terminal blocks, while the vented grid | power series suit large rooms with regular maintenance.

Frequently asked questions

What does FT mean in 121500 FT?

FT stands for front terminals: the poles are on the front face so connections need no additional connectors.

What capacity does 121500 FT have?

The green series data sheet gives 150 Ah at C10 and 154 Ah at C8, with 140 Ah at C3 and 118 Ah at C1.

How wide is the operating range?

-35 °C to +50 °C for the green series, narrower than -40 °C to +55 °C for the standard pure series.

What float voltage should be set?

2.3 volts per cell at 20 °C, plus or minus 1 percent, and 2.288 volts at 25 °C.

Does Seven Star LLC act as a HOPPECKE distributor?

No, we are an independent supplier in Muscat and supply HOPPECKE items on request rather than acting as a HOPPECKE channel partner.

Documents and quotation

Download the official HOPPECKE datasheet and manual for grid Xtreme VR 121500 FT from this page. As an independent supplier based in Muscat, Seven Star LLC supplies HOPPECKE items on request: use the quote form with the quantity you need. Check every value in the documents against your own specification before you order. Browse similar items in the category.

Datasheets & Documents
  • PDF Datasheet HOPPECKE grid | Xtreme VR FT green series data sheet (EN, PDF) Download
  • PDF Manual HOPPECKE grid | Xtreme VR installation and operating manual (EN, PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HOPPECKE is a German family-owned manufacturer of industrial batteries and energy storage, based in Brilon, and describes itself as the largest privately owned European manufacturer of industrial batteries. Its website states more than 2,000 employees in 22 countries, 12 production locations and customers in 150 countries.

Stationary, solar and rail batteries

The company serves four application areas: trak for intralogistics, grid for stationary battery systems such as UPS and telecom, sun for the intermediate storage of renewable energies, and rail for rail and metro systems. The grid range covers grid | Xtreme VR pure lead AGM blocks, grid | XtremeStack racks, grid | power vented cells and FNC fibre nickel-cadmium cells, while sun | power adds cyclic AGM and gel batteries.

Supply through Seven Star LLC

Seven Star LLC is an independent supplier in Muscat that quotes HOPPECKE batteries for projects in Oman and the GCC, with the official data sheet or brochure and manual attached to each product page.

Frequently Asked Questions

What does FT mean in 121500 FT?
FT stands for front terminals: the poles are on the front face so connections need no additional connectors.
What capacity does 121500 FT have?
The green series data sheet gives 150 Ah at C10 and 154 Ah at C8, with 140 Ah at C3 and 118 Ah at C1.
How wide is the operating range?
-35 °C to +50 °C for the green series, narrower than -40 °C to +55 °C for the standard pure series.
What float voltage should be set?
2.3 volts per cell at 20 °C, plus or minus 1 percent, and 2.288 volts at 25 °C.
Does Seven Star LLC act as a HOPPECKE distributor?
No, we are an independent supplier in Muscat and supply HOPPECKE items on request rather than acting as a HOPPECKE channel partner.