Riello UPS Sentinel Pro2 SP2 3000 Online Tower UPS
Description
The Riello UPS Sentinel Pro2 SP2 3000 is the 3 kVA model of a compact ON LINE double-conversion tower UPS for servers, network cabinets, voice and data equipment and small control rooms. The load is always fed by the inverter, so mains sags, surges and short interruptions do not reach the equipment. Riello UPS lists the range from 700 to 3000 VA with an output power factor of 1, so a 3000 VA unit delivers 3000 W.
Why an online tower UPS suits single-phase IT and control loads
Double conversion gives a filtered, stabilised sine wave output that is independent of the mains quality. The datasheet classifies the range as VFI under IEC 62040-3 and gives an input window of 140 to 276 V at 50 percent load, or 184 to 276 V at full load, before the batteries are used. A wide window reduces battery cycling where the supply is weak.
Sentinel Pro2 also offers an emergency function with progressive soft start of the inverter, an ECO and SMART ACTIVE mode with 98 percent stated efficiency, optional frequency-converter operation and EnergyShare sockets that can switch off non-critical loads under configurable conditions. The datasheet states a noise level below 40 dBA at 1 m in ECO mode.
Technical specifications
| Parameter | Specification |
|---|---|
| Model family | SP2 700, SP2 1000, SP2 1000 ER, SP2 1500, SP2 2200, SP2 2200 ER, SP2 3000, SP2 3000 ER |
| Output power (SP2 3000) | 3000 VA / 3000 W, power factor 1 |
| Technology | ON LINE double conversion, VFI-SS-111 per IEC 62040-3 |
| Input voltage | 220 / 230 / 240 V, 50 / 60 Hz; 140 to 276 V at 50 percent load, 184 to 276 V at 100 percent load without battery |
| Input power factor | 1 |
| Output voltage and distortion | Sinusoidal; below 2 percent with linear load, below 4 percent with non-linear load |
| Output frequency | 50 or 60 Hz or self-learning |
| Overload | Below 150 percent for 4 s, 150 percent for 1 s |
| Efficiency | Up to 93.7 percent ON LINE; 98 percent in ECO and SMART ACTIVE modes |
| Battery | VRLA AGM, maintenance-free; Supercaps available on 1000 and 3000 VA; recharge time 2 to 4 h on standard models |
| Dimensions (W x D x H) | 158 x 422 x 235 mm and 190 x 446 x 333 mm depending on model |
| Weight | 7 to 26.3 kg depending on model (ER versions have no internal batteries) |
| Connections | USB, RJ45 serial with dry contacts, communication slot; 1 x C20 input; 8 x C13 plus 1 x C19 output on the 3 kVA models |
| Operating environment | 0 to 40 degrees C, 5 to 95 percent humidity non-condensing, RAL 9005 |
| Standards | LV 2014/35/EU, EMC 2014/30/EU, IEC EN 62040-1, IEC EN 62040-2, RoHS; UL 1778 and CSA C22.2 No. 107.3-14 |
Choosing between standard and ER models
Standard models carry internal VRLA batteries and a recharge time of 2 to 4 hours. ER versions ship without internal batteries and with a more powerful charger, intended for long autonomy with external battery cabinets; Riello UPS offers matching BTC cabinets in 36 V and 72 V versions. Before ordering, confirm the connected load in watts, the autonomy target in minutes, the room temperature (the datasheet recommends 20 to 25 degrees C for battery life) and whether a manual bypass or a network card is needed. Options listed by Riello UPS include MULTICOM and NETMAN communication cards, Multi I/O, MultiPanel and a 16 A manual bypass.
For a comparison with another brand already listed, see the APC SRT3000XLI Smart-UPS SRT 3000VA; more units are in the UPS and batteries category.
Sentinel Pro2 models
| Model | Output | Note |
|---|---|---|
| SP2 700 | 700 VA / 700 W | Standard, internal batteries |
| SP2 1000 | 1000 VA / 1000 W | Standard; Supercaps option |
| SP2 1000 ER | 1000 VA / 1000 W | Extended runtime, no internal batteries |
| SP2 1500 | 1500 VA / 1500 W | Standard |
| SP2 2200 | 2200 VA / 2200 W | Standard |
| SP2 2200 ER | 2200 VA / 2200 W | Extended runtime |
| SP2 3000 | 3000 VA / 3000 W | Standard; Supercaps option |
| SP2 3000 ER | 3000 VA / 3000 W | Extended runtime |
Documents and quotation
The Riello UPS Sentinel Pro2 datasheet (DATSP2A1Y26AREN) is attached to this page. Check the datasheet for the exact input plug and socket layout of the model you need. Seven Star LLC is an independent supplier in Muscat. Send the exact model code, the load in kW or VA, the input and output voltage and the autonomy needed, and we will quote against the manufacturer data.
Datasheets & Documents
- Datasheet Riello UPS Sentinel Pro2 datasheet (DATSP2A1Y26AREN, EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Riello UPS is the uninterruptible power supply brand of the Riello Elettronica Group, with design and production based in Legnago, near Verona, Italy. Its ON LINE and line-interactive UPS cover single-phase IT protection, three-phase industrial systems and modular critical-power installations. Seven Star LLC is an independent supplier in Muscat and lists Riello UPS models together with the manufacturer datasheets.
Riello UPS ranges for IT, industry and data centres
The Sentinel Pro2, Sentinel Dual2 and Sentinel Tower families protect servers, network equipment and small control rooms from 700 VA to 10 kVA. Sentryum, Master MPS and Master HP serve three-phase commercial and industrial loads, while NextEnergy and Multi Power2 modular systems address larger data-centre and critical-power installations. The manufacturer publishes technical data, option lists and dimensions for each range.
Ordering UPS equipment
Send the exact model code, the load in kW or VA, the input and output voltage, the autonomy required and the battery type. We check the request against the manufacturer datasheet before quoting.
Related products
Frequently Asked Questions
The inverter feeds the load continuously, so the output is isolated from mains disturbances and there is no transfer time. The datasheet classifies Sentinel Pro2 as VFI under IEC 62040-3.
Riello UPS lists 3000 VA at output power factor 1, so 3000 W, with overload capability below 150 percent for 4 seconds and 150 percent for 1 second.
The ER version has no internal batteries and a more powerful battery charger so that runtime can be extended with external battery cabinets.
Yes. The output frequency can be set to 50 Hz, 60 Hz or self-learning according to the datasheet, and the unit can also be used as a frequency converter.
The UPS operates from 0 to 40 degrees C. Riello UPS recommends 20 to 25 degrees C to get the longest battery life.

Reviews
There are no reviews yet.