Brand:

APC RBC48 Replacement Battery Cartridge #48

Description

What the RBC48 is for

APC RBC48 is catalogued by APC as Replacement Battery Cartridge #48 with 2 Year Warranty.

Chemistry: lead-acid battery. Each unit measures 108 mm x 132 mm x 150 mm (H x W x D) and weighs 5 kg.

Technical specifications

Parameter Specification
Part number RBC48
Product or component type Replacement battery cartridge
Battery type Lead-acid battery
Provided equipment All required connectors / Battery recycling guide / Reusable packaging / Installation guide
Range of product Replacement Battery Cartridges
Height 108 mm
Width 132 mm
Depth 150 mm
Net weight 5 kg
Mounting mode Not rack-mountable
USB compatible No
Battery capacity 7.0 Ah
Number of battery blocks per string 2
Number of battery free slots 0
Number of battery filled slots 0
Device mounting Stand alone battery stack
Battery voltage 24 V
Number of battery replacement quantity 1
Ambient air temperature for operation 0…40 °C
Operating altitude 0…10000 ft
Relative humidity 0…95 %
Ambient air temperature for storage -15…45 °C
Storage altitude 0…15240 m
Storage Relative Humidity 0…95 %
Warranty (in months) 24

Compatibility and replacement notes

Battery voltage: 24 V. Battery capacity: 7.0 Ah.

Battery replacement should be matched to the exact UPS model named in the APC documentation, because voltage, connector and cartridge count differ between systems. Used batteries must be recycled according to local regulations.

Physical data and environment

Dimensions are 108 mm x 132 mm x 150 mm (H x W x D), and the unit weighs 5 kg.

Listed operating limits: operating temperature 0…40 °C; relative humidity 0…95 %; operating altitude 0…10000 ft.

Warranty recorded by APC (months): 24.

The APC RBC48 is listed with type lead-acid battery, voltage 24 V, capacity 7.0 Ah. Replacement batteries should be fitted as a complete set of the same type and age, because mixing old and new cells shortens the life of the whole string. Fit and wire the cartridge exactly as shown in the installation sheet, and recycle used batteries according to local regulations.

The unit measures 108 mm x 132 mm x 150 mm (H x W x D) and weighs 5 kg, so check the available space and the handling requirements before delivery. Listed environmental limits: operating temperature 0…40 °C; relative humidity 0…95 %; altitude 0…10000 ft. Store and operate the battery within these limits, because heat shortens service life.

The warranty period recorded in the product data is 24 months. If a project requires certificates or test reports, include that request with the quotation request.

The RBC48 within the APC range

APC by Schneider Electric is one of the most widely installed UPS brands worldwide, covering single-phase and three-phase UPS systems, replacement batteries, battery packs, management cards and installation accessories.

An APC Replacement Battery Cartridge (RBC) is a pre-assembled set of sealed valve-regulated lead-acid (VRLA) blocks, wired, terminated and packed so that the battery of a UPS can be changed as one unit. Each cartridge number is listed for specific UPS models, and the cartridge arrives ready to fit with the required connectors. Valve-regulated lead-acid batteries typically need replacement every three to five years, or earlier when the UPS self-test reports a weak battery. On UPS models that support hot-swap, the cartridge can be changed with the load still running; otherwise plan a short shutdown.

In the product data for the APC RBC48, its battery technology is listed as lead-acid battery; the battery voltage is 24 V. These values are the starting point for matching it to the rest of the installation.

Applying the RBC48 on sites in Oman and the GCC

The listed operating temperature tops out at 40 °C. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, so the equipment belongs in an air-conditioned room or cabinet rather than an open plant area. Battery temperature has the biggest effect on service life: as a rule of thumb, the life of a valve-regulated lead-acid battery roughly halves for every 10 °C above 25 °C, so a room held at 20 to 25 °C pays back in fewer battery replacements. Dust and humidity are the other two regional factors: fine dust blocks fans and filters, and coastal humidity and salt attack contacts, so a clean, sealed room and regular inspection protect the investment.

Service life and maintenance of the APC RBC48

Plan inspections at least once a year: check that the equipment is clean, that fans and filters are free of dust, that cable terminations are tight and that no alarms are stored in the event log. Where a UPS is involved, run a self-test and a short battery test under real load, and record the results so that a gradual loss of runtime is noticed before it becomes a failure. Replace batteries as a complete set, never by mixing old and new blocks, and keep the replaced items for proper recycling.

Seven Star LLC supplies APC equipment as an independent supplier based in Muscat. Original product documents are provided where available, and the part number RBC48 can be quoted together with related batteries, accessories and spares in one enquiry.

What to send with an enquiry for the RBC48

A complete enquiry lets Seven Star LLC confirm compatibility and quote without back-and-forth. Include:

  • The model and serial number of the UPS the cartridge will be fitted in
  • The number of cartridges installed in that UPS
  • The date the current battery was installed, if known
  • Whether the old battery should be collected for recycling
  • The delivery location in Oman (for example Muscat, Sohar, Duqm or Salalah) or elsewhere in the GCC, and the required date

Other APC UPS systems, batteries and accessories and Schneider Electric equipment can be combined in one quotation.

Documents and quotation

The user guide for the RBC48 is hosted on this page under Documents so the wiring, installation and operating details can be reviewed before ordering.

The single-unit shipping package is listed as 16.800 cm (height) x 22.400 cm (width) x 16.800 cm (length) with a packed weight of 5.910 kg. Use these values when planning freight, lifting and receiving space.

To order, submit the part number RBC48, the quantity and the delivery location. Related items are grouped under UPS and Batteries. Seven Star LLC is an independent supplier based in Muscat and answers with availability and a quotation.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

APC is Schneider Electric's brand for uninterruptible power supplies, power distribution units, cooling and racks for IT and control systems. American Power Conversion was founded in 1981 by three engineers from MIT's Lincoln Laboratory and grew into one of the largest UPS makers in the world. Schneider Electric completed its acquisition of APC on 14 February 2007, combined it with MGE UPS Systems, and since 2011 APC has been a product brand of Schneider Electric.
Seven Star LLC lists APC uninterruptible power supplies from desktop Back-UPS units to modular Symmetra systems, together with battery packs and network cards, and sources them for sites in Oman.

APC company profile
Founded1981, USA, as American Power ConversionFoundersThree engineers from MIT Lincoln LaboratoryOwnershipSchneider Electric since 14 February 2007; an APC by Schneider Electric product brand since 2011Product familiesBack-UPS, Easy UPS, Smart-UPS line-interactive, Smart-UPS On-Line SRT and SRV, Galaxy three-phase UPS, rack PDUs, NetShelter racks, network management cards and EcoStruxure IT software

Milestones
1981: American Power Conversion is founded by three MIT Lincoln Laboratory engineers.2006: Schneider Electric announces the acquisition of APC on 30 October.2007: The acquisition is completed on 14 February; APC is combined with MGE UPS Systems.2011: APC becomes a product brand within Schneider Electric.

APC UPS families on this page

APC names its UPS lines by topology and size:

Back-UPS and Back-UPS Pro: line-interactive units for workstations and small loads, such as BX1600MI-MS and BR1600MISmart-UPS: line-interactive models with sine wave output, including SMT750I, SMC1000IC and the Smart-UPS X SMX3000HV with its SMX120BP external battery packSmart-UPS SRT and Smart-UPS RT: online double-conversion units, for example SRT2200XLI, SRT3000XLI, SRT5KRMXLI and SURT8000XLIEasy UPS Online: SRV2KILSymmetra LX and Symmetra PX: modular, scalable systems for larger loads

The AP9641 Network Management Card 3 adds remote monitoring to UPS models with a SmartSlot.

Where APC UPS systems are used

In industrial plants across the GCC, APC UPS units back up DCS and PLC cabinets, operator stations, SCADA servers, telecom racks, fire and gas panels and analyzer shelters. Online double-conversion models are normally chosen for control systems because the load is always fed through the inverter. Line-interactive units suit office IT and less critical loads.

APC products we list
FamilyExamplesUPS and BatteriesAP9641 Network Management Card 3, BR1600MI Back-UPS Pro 1600VA/960W, BX1600MI-MS Back-UPS 1600VA Tower UPS, SMC1000IC Line-Interactive UPS 1000VA 600W, SMC1500I Smart-UPS C 1500VA/900W, SMT750I Smart-UPS 750VA/500W Line-Interactive, SMX120BP Smart-UPS X 120V External Battery, SMX1500RMI2U Smart-UPS X 1500VA Rack/Tower and 9 more

Ordering APC UPS units and parts: what we need

Send the full SKU, for example SRT3000XLI, and not only the VA rating. The letters carry meaning: an I in the suffix marks a 230 V international model, XL an extended-run version that accepts external battery packs, and RM a rack-mount form. For a new requirement, give load in watts, input and output voltage, required runtime, tower or rack format, and the plug or hardwire arrangement. For batteries, send the UPS SKU and serial number so the correct replacement battery cartridge can be found in APC documentation.

Replacement batteries, battery packs and spares
Most APC service work is battery work. APC Replacement Battery Cartridges, sold under RBC and APCRBC numbers, are sets of sealed valve-regulated lead-acid blocks that arrive pre-wired with the connectors for the UPS models they are listed for, so a weak battery can be changed as one unit and, on hot-swap models, without switching the load off. Some newer cartridges carry an -LI suffix for lithium-ion versions. External battery packs extend runtime on XL and SRT models, and are chained to the UPS through the battery connector on the rear panel. To find the right cartridge, send the UPS SKU and serial number; the same UPS can use different cartridges across hardware revisions.
Modular and three-phase APC systems
Symmetra LX and Symmetra RM: single-phase modular UPS frames with hot-swappable power modules, battery modules and intelligence modules, so a failed module can be exchanged while the load stays on protected power.Symmetra PX: three-phase modular UPS for data rooms, built from power modules with N+1 redundancy and battery modules for runtime.Smart-UPS VT: three-phase double-conversion UPS for small data rooms and technical buildings.Silcon: large three-phase UPS based on delta conversion, still running in many plants and data centres; spare part kits are listed in levels (SPL1 to SPL4) so sites can hold the parts that match their service plan.Easy UPS On-Line (SRV): cost-focused double-conversion units, many with external battery pack support.
APC UPS in Oman and GCC conditions
Oman supplies 240 V single-phase and 415 V three-phase at 50 Hz, so international models with an I suffix (230 V nominal, adjustable to 240 V on most Smart-UPS units) are the usual choice. Heat is the main enemy: most APC UPS units are rated for operation up to 40 °C, while summer shade temperatures in Muscat and the interior pass 45 °C, and a lead-acid battery loses roughly half its service life for every 10 °C above 25 °C. Install UPS and batteries in a cooled room, keep filters clean in dusty inland sites, and size the standby generator with margin for UPS input and battery charging current.
All APC UPS systems, batteries and accessories on this site are grouped under UPS and Batteries, and the wider Schneider Electric range can be quoted together with them.

Facts checked against APC by Schneider Electric's published history, October 2026.

Browse APC products by category: UPS and Batteries.
Need a replacement battery for an APC UPS you already run? Use our APC UPS replacement battery finder to match the model to its official RBC cartridge.

Frequently Asked Questions

What are the electrical ratings of the APC RBC48?
The APC RBC48 is listed with a battery voltage of 24 V and a capacity of 7.0 Ah.
What is supplied with the APC RBC48?
APC lists these supplied items: all required connectors / battery recycling guide / reusable packaging / installation guide.
What are the dimensions and weight of the APC RBC48?
The listed dimensions are 108 mm x 132 mm x 150 mm (H x W x D) and the weight is 5 kg.
What operating conditions apply to the APC RBC48?
Listed limits: operating temperature 0…40 °C; relative humidity 0…95 %.
How can I request a quotation for the APC RBC48?
Send the part number RBC48 with quantity and delivery location through the RFQ form. Seven Star LLC is an independent supplier in Muscat and replies with availability and a quotation.