Brand:

Blue-White MS6 SONIC-PRO Ultrasonic Chemical Feed Flow Meter

Description

MS6 is the SONIC-PRO ultrasonic flow meter from Blue-White, made to verify chemical feed in small lines from 10 to 10,000 millilitres per minute (0.158 to 158.5 GPH) at up to 13.8 bar. A PVDF and PEEK body, an isolated 4-20 mA output and a pulse output let it close the loop around a metering pump.

Ultrasonic flow verification for chemical dosing lines

Because the MS6 measures with ultrasound, it has no moving parts or float to foul, and it reads acoustically conductive liquids that contain particulates and bubbles up to 50,000 ppm. The meter comes pre-calibrated with chemical profiles: water, aqueous ammonia 10 percent, ammonium hydroxide 30 percent, ferric chloride 40 percent, sodium bisulfite 40 percent, sodium hypochlorite 12.5 percent, sodium permanganate 40 percent, hydrofluorosilicic acid 25 percent and ammonium sulfate 10 percent, and a custom calibration is possible for other liquids.

Outputs are an isolated, fully configurable 4-20 mA signal, a 0 to 1,000 Hz pulse output and one solid-state relay (24 VDC, 100 mA) that can be set on flow rate or on a flow total for timed batch operation. The meter is set up from a PC with the free Blue-Central software over USB-C, which also gives real-time rate, total and diagnostics and allows field firmware upgrades.

Key features as printed in the datasheet

  • Range 10-10,000 mL/min (0.158-158.5 GPH) in two models, MS6-1 and MS6-2.
  • 200 psi (13.8 bar) maximum pressure; PVDF and PEEK wetted body.
  • Isolated 4-20 mA and 0-1,000 Hz pulse outputs, one solid-state relay.
  • Nine pre-calibrated chemical profiles and custom calibration.
  • Rate averaging selectable 1, 4, 8, 16 or 32 seconds.
  • True-union inline fittings; 1/2 in barb, 1/2 in male NPT and PVC slip fittings.
  • NEMA 4X (IP66); NSF/ANSI 61; 5-year warranty on the display model.

Technical specification

General specification

Parameter Specification
Flow range MS6-1: 10-5,000 mL/min (0.158-79.2 GPH); MS6-2: 100-10,000 mL/min (1.58-158.5 GPH)
Maximum pressure 200 psi (13.8 bar)
Fluids Acoustically conductive; particulates and bubbles 50,000 ppm or less
Operating / storage temperature 14 to 104 F (-10 to 40 C) / -40 to 158 F (-40 to 70 C)
Relative humidity 0 to 90 percent
Power 5 VDC, 5 W maximum, via supplied transformer
Units Rate and total in US gallons, litres or millilitres; seconds to days
Data outputs Isolated 4-20 mA; 0-1,000 Hz pulse
Relay One solid state, 24 VDC, 100 mA maximum
Display LCD with white LED backlight
Computer connection USB-C (USB-A to USB-C cable included)
Enclosure NEMA 4X (IP66), polycarbonate with stainless-steel hardware
Weight / size 1.5 lb (0.68 kg); 10.02 H x 3.79 diameter in (254.5 x 96.1 mm)
Standards NSF/ANSI 61; RoHS

Software and power supply

Parameter Specification
Blue-Central software Windows 10 and 11; Mac OS X 10.11 to 10.15
Transformer, US 115 VAC 60 Hz to 5 VDC, NEMA 5/15
Transformer, Europe 230 VAC 50 Hz to 5 VDC, CEE 7/VII
Transformer, AU/NZ 240 VAC 50 Hz, AS 3112
Transformer, UK 230 VAC 50 Hz, BS 1363/A

Materials

Parameter Specification
Transducer PEEK
Body PVDF and PEEK
O-rings TFE/P (EP optional)
Included fittings PVDF 1/2 in ID barb and elbow; PVDF 1/2 in male NPT and elbow; PVC 1/2 in slip

Selection and ordering guide

The model code is MS6 [flow range] [display] [O-ring] X: range 1 covers 10-5,000 mL/min and range 2 covers 100-10,000 mL/min; the display digit 2 is the meter-mounted display; O-ring V is TFE/P and E is EP. The sample MS6-1-2-V-X is printed on the sheet. The datasheet notes that the remote-mount display option was discontinued on 1 January 2026.

Select the range so that normal dosing flow lies inside the accuracy curve; the datasheet curves show indicated against actual flow for 12.5 percent sodium hypochlorite, 25 percent fluorosilicic acid and sodium permanganate.

Installation and operation notes

Install the meter inline in a full pipe using the fittings that match your tubing; the true unions allow removal for maintenance. The temperature-versus-pressure graph in the sheet limits working pressure to 200 psi at about 70 F with derating at higher fluid temperature, so check it for warm fluids.

Connect the supplied transformer for power, connect the 4-20 mA and pulse outputs to the controller using the wiring section of the manual, and use Blue-Central to select the chemical profile, units and rate averaging. Custom chemical calibration is described in the manual for liquids not in the profile list.

Applications in Oman and the GCC

Verification of chemical feed is valuable in desalination and municipal treatment where under-dosing of hypochlorite, bisulfite, ferric chloride or fluoride must be detected. A metering pump with a 4-20 mA input can be paced from the pulse or analogue signal, and the relay can trigger alarms or batch feeds.

The operating ambient limit of 104 F (40 C) printed on the datasheet is lower than the pumps, so in hot Gulf plant rooms keep the meter electronics shaded and ventilated.

Compatible accessories and related items

The datasheet points to the Blue-White metering pumps (FLEXFLO and CHEM-FEED) and listed accessories such as tubing and injection fittings on the accessory pages; the MS6 can also be used with the variable area meters F-440 and F-550 for local reading.

Frequently asked questions

What flow range does the Blue-White MS6 measure?

10 to 10,000 mL/min across two models: MS6-1 to 5,000 mL/min and MS6-2 to 10,000 mL/min.

What outputs does the MS6 have?

An isolated 4-20 mA output, a 0-1,000 Hz pulse output and one solid-state relay.

Which chemicals are pre-calibrated?

Water, ammonia, ferric chloride, sodium bisulfite, sodium hypochlorite, sodium permanganate, fluorosilicic acid and ammonium sulfate at the strengths listed on the sheet.

How is the MS6 configured?

With the Blue-Central software on Windows or Mac over a USB-C cable.

Is Seven Star LLC a Blue-White distributor?

No. Seven Star LLC is not a Blue-White distributor; it is an independent Muscat-based supplier that quotes Blue-White products on request.

Documents and quotation

This page carries the official Blue-White technical data sheet for MS6. Seven Star LLC is an independent supplier in Muscat and sources Blue-White products on request; tell us the quantity and delivery point to receive a quotation. Always confirm the order code and technical values in the document first. See more in the product category.

Datasheets & Documents
  • PDF Datasheet Blue-White MS6 technical data sheet 85000-135 (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Blue-White Industries is an American maker of metering pumps, flowmeters and water treatment accessories, based in Huntington Beach, California. It was founded in 1957 by Ozzie King, a pool builder and inventor who switched King Blue-White Pools from building pools to manufacturing; his F-300 series flowmeters became a pool industry standard. Today Blue-White makes peristaltic and diaphragm metering pumps for municipal and industrial water treatment.

Seven Star LLC is an independent supplier in Muscat. We list Blue-White pumps and flow meters, with the official technical data sheet attached to each product page, for water treatment and process projects in Oman and the GCC.

Blue-White company profile

Founded 1957, California, by Ozzie King
Headquarters Huntington Beach, California
Early product F-300 series flowmeters
Markets Municipal and industrial water treatment, irrigation, semiconductor, food and beverage
Product families FLEXFLO A1, A5 and M3 peristaltic metering pumps, CHEM-FEED C2, C3 and CD3 diaphragm metering pumps, variable area and ultrasonic flowmeters, paddlewheel flow sensors

Milestones

  • 1957: Ozzie King incorporates Blue-White Industries.
  • 2017: Blue-White marks 60 years.

Blue-White product series

FLEXFLO peristaltic metering pumps include the A1, the M3 for 126 l/h and the A5 for up to 2021 l/h; they pump chemicals that gas off, such as sodium hypochlorite, without vapour locking. CHEM-FEED diaphragm pumps include the C2, the high-output C3, the multi-diaphragm CD3 and the mechanical C-600P.

Flow measurement includes the F-440 polysulfone and F-550 acrylic variable area flow meters and the MS6 SONIC-PRO ultrasonic flow meter for chemical feed lines.

Where Blue-White equipment is used

Disinfection and pH control in drinking water and wastewater plants, chemical dosing in desalination and cooling water, pools, carwashes and process industries.

Blue-White products we list

Family Examples
Pumps A1 FLEXFLO Peristaltic Metering Pump, A5 FLEXFLO Peristaltic Metering Pump 202…, C2 CHEM-FEED Diaphragm Metering Pump 62.…, C3 CHEM-FEED High-Output Diaphragm Dosin…, CD3 CHEM-FEED Multi-Diaphragm Metering P…, M3 FLEXFLO Peristaltic Metering Pump 126…

Ordering Blue-White products: what we need

Send the model, flow range, discharge pressure, chemical and concentration, tube or diaphragm material, supply voltage and the control input required (manual, 4-20 mA, pulse or network).

Facts checked against Blue-White's 60th anniversary release and company profiles, October 2026.

Frequently Asked Questions

What flow range does the Blue-White MS6 measure?
10 to 10,000 mL/min across two models: MS6-1 to 5,000 mL/min and MS6-2 to 10,000 mL/min.
What outputs does the MS6 have?
An isolated 4-20 mA output, a 0-1,000 Hz pulse output and one solid-state relay.
Which chemicals are pre-calibrated?
Water, ammonia, ferric chloride, sodium bisulfite, sodium hypochlorite, sodium permanganate, fluorosilicic acid and ammonium sulfate at the strengths listed on the sheet.
How is the MS6 configured?
With the Blue-Central software on Windows or Mac over a USB-C cable.
Is Seven Star LLC a Blue-White distributor?