Viking Pump HJ4197 Stainless Steel Internal Gear Pump
Description
Overview
Alcohols, solvents and mildly corrosive process liquids call for something better than cast iron, and Viking Pump HJ4197 meets that need with a stainless steel pump body. It is a foot-mounted internal gear pump with 1 1/2 inch Class 150 flanged ports and a nominal capacity of 20 GPM (4.5 m3/h) at 1750 rpm on 60 Hz, or 17 GPM (3.8 m3/h) at 1450 rpm on 50 Hz. The unit weighs about 50 lb (23 kg), and every wetted pumping part is made of stainless alloy or carbon graphite. Seven Star LLC is an independent supplier serving Oman and the GCC.
This page describes the pump using the Viking catalog section for the 4197 series and the related 4197-SEP version, and explains how the HJ size fits the family.
A stainless pump for thin and corrosive liquids
The casing, head and relief valve of the Viking Pump HJ4197 are cast stainless steel to ASTM A743 Grade CF8M, the cast equivalent of 316. The rotor is the same material, case hardened for wear resistance, and the idler is made from 770 stainless alloy, selected because the pair of dissimilar alloys resists galling when the liquid has no lubricity. A PPS composite idler is also offered for very thin liquids. The rotor shaft is stainless to ASTM A276 Type XM-19 or 316, and the idler pin is hard coated Type 316 stainless with a Colmonoy No. 6 coating.
Viking Pump HJ4197 data from the catalog
| Parameter | Value |
|---|---|
| Model | Viking Pump HJ4197, series 4197, stainless steel externals, foot mounted, catalog section 1741 |
| Port size and type | 1 1/2 inch, Class 150 flanged |
| Nominal rating, 60 Hz (100 SSU and below) | 20 GPM (4.5 m3/h) at 1750 rpm |
| Nominal rating, 50 Hz | 17 GPM (3.8 m3/h) at 1450 rpm |
| Casing and head | Stainless steel, ASTM A743 Grade CF8M |
| Rotor | Stainless steel, ASTM A743 Grade CF8M, case hardened |
| Idler | 770 stainless steel alloy; PPS composite idler available for thin liquids |
| Rotor shaft | Stainless steel, ASTM A276 Type XM-19 or 316 Condition B |
| Idler pin | Stainless steel, ASTM A276 Type 316, Colmonoy No. 6 coated |
| Idler bushing | Carbon graphite |
| Pressure relief valve | Stainless steel, ASTM A743 Grade CF8M |
| Mechanical seal | Stainless steel, PTFE, carbon graphite and silicon carbide |
| Maximum differential pressure | 200 PSI (14 bar) above 750 SSU; lower for thinner liquids |
| Maximum hydrostatic pressure | 400 PSIG (27 bar) |
| Temperature range, standard seal | 0 to 350 F (minus 20 to 175 C); extra clearances above 225 F |
| Viscosity limit | up to 25,000 SSU (5,500 cSt) |
| Shipping weight with valve | 50 lb (23 kg) |
Mechanical seal and bearings
A positive drive mechanical seal is fitted as standard. It is a simple self-adjusting design suited to liquids such as alcohols and solvents, built from stainless steel, PTFE elastomer parts and a carbon graphite against silicon carbide face pair. Ball bearings sealed for life are mounted, one outside the seal and one thrust bearing, and these allow service up to the 200 PSI (14 bar) differential rating. A micrometer thrust adjustment lets the user restore end clearance as the pump wears.
Viking Pump HJ4197 compared with other 4197 sizes
The GG4197 below it has 1 inch ports and delivers 10 GPM at 1750 rpm in a 20 lb package. The HL4197 shares the 1 1/2 inch ports and weight of the HJ but is rated 30 GPM at 1750 rpm. Above them, the AS4197 moves to 3 inch flanged ports with 35 GPM at 1150 rpm and 115 lb, and the AL4197 delivers 75 GPM. The HJ is therefore the right pump when your line is 1 1/2 inch and 20 GPM is enough; select the HL if you need 30 GPM without changing the piping.
Where it is used
- Alcohol and solvent transfer in chemical blending and coating plants.
- Compressor lubrication and fuel services where stainless is wanted.
- Cooling and heat transfer fluids with mild corrosivity.
- Circulation of process liquids that are clean and thin.
The SEP variant
The catalog separates the standard 4197 from the 4197-SEP series. The SEP pumps use fluorosilicone elastomers and low temperature materials so they can be used for subzero solvent transfer or circulation, with a temperature range of minus 95 to plus 225 F (minus 70 to plus 105 C). They are also assembled and tested using only food grade liquids. This listing is for the standard Viking Pump HJ4197 with PTFE seal parts and the broader 0 to 350 F range; if you need the SEP version, specify HJ4197-SEP1 in your enquiry.
Selection and installation
Because the ports are Class 150 flanges, use matching companion flanges and gaskets suited to the liquid. Locate the pump close to the source, keep the suction line short and fit a strainer. Thin liquids like solvents provide almost no lubrication, so do not run the pump dry and ensure the casing is full before starting. Check the direction of rotation relative to the relief valve, which must point towards the suction side.
Do not exceed the differential pressure limit: 200 PSI above 750 SSU, with lower values for thinner liquids as noted in the catalog. For liquids under 38 SSU, the allowed differential is much lower, so verify the figure before ordering.
Maintenance
Maintenance is concentrated on the mechanical seal, the idler bushing and the thrust setting. Replace the seal if leakage appears, and replace the bushing before the idler pin scores. Keep seal kits in stock if the pump handles a hazardous liquid, and record the pressure after each overhaul to detect wear early.
Why stainless matters for Gulf conditions
Coastal humidity and salt-laden air attack unprotected iron surfaces from the outside, while process liquids attack from the inside. A stainless casing resists both, and it keeps trace iron out of products such as alcohols, solvent blends and chemical intermediates where colour or purity is monitored. For plants in the Gulf that run outdoors on a washdown or splash basis, the stainless body also means that the pump does not need repainting. The trade-off is a higher price than cast iron and a somewhat lower pressure rating than the steel externals 4193, which is why the catalog quotes 200 PSI against 250 PSI.
Drive and speed
Direct drive by a standard four pole motor gives the rated flows. On liquids thicker than 100 SSU the flow increases slightly and the power draw rises, so the motor selection should follow the catalog horsepower guidance for the viscosity and pressure involved. A gear reducer allows the pump to handle liquids up to the 25,000 SSU limit by reducing the speed, which avoids excess shear and cavitation at the inlet.
Related items you may also need: KRACHT PT 350-A-080-188 Bellhousing for KF Gear Pump | Danfoss 180B0036 PAH 25 High-Pressure Water Pump | Debem Equaflux 100 Pulsation Damper for AODD Pumps | All Viking Pump products.
Points to confirm for the Viking Pump HJ4197
- If the Viking Pump HJ4197 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Viking Pump HJ4197 request we confirm the exact code and lead time in writing.
- Dimensions, ratings and connection data for the Viking Pump HJ4197 are in the datasheet attached to this page.
- The Viking Pump HJ4197 belongs to our positive displacement pumps range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Viking Pump HJ4197 on critical service often hold a spare unit in the store.
Documents and quotation
The Viking catalog section for the 4197 series is attached, with specifications, dimensions and NPSH curves. To obtain a quotation for Viking Pump HJ4197, please send the quantity, the liquid, temperature, pressure and delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Viking Pump HJ4197 Stainless Steel Internal Gear Pump Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.
Viking Pump company profile
| Founded | 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth |
|---|---|
| Headquarters | Cedar Falls, Iowa, USA |
| Ownership | A unit of IDEX Corporation since 1989 |
| Core technology | Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps |
| Typical liquids | Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives |
| Standards | API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot |
Milestones
- 1904: Jens Nielsen patents his internal gear pump design.
- 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
- 1989: Viking becomes part of IDEX Corporation.
- 2011: Viking marks 100 years in Cedar Falls.
- Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.
How a Viking internal gear pump works
An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.
Where Viking pumps are used in Oman and the GCC
In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.
Viking Pump models we list
| Family | Examples |
|---|---|
| General-purpose internal gear pumps | KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A |
| Jacketed and heated pumps | KK224C, Q224C, M224A, KK124E asphalt |
| Steel and stainless steel pumps | L123C, QS4123C, RS4323A, KK127C, Q4127C |
| API 676 pumps | LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA |
| Motor speed, external gear and mag drive pumps | HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive |
| Special-duty pumps | KK4924A ammonia, KK4624C abrasive, LVP41027 vane |
Ordering Viking pumps: what we need
Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.
Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.
Browse Viking Pump products by category: Positive Displacement Pumps.
FAQ
Questions about the Viking Pump HJ4197 Stainless Steel Internal Gear
Answers from our engineering team on installation, compatibility and integration.
01What capacity does the Viking Pump HJ4197 have?
The catalog rating is 20 GPM (4.5 m3/h) at 1750 rpm on 60 Hz and 17 GPM (3.8 m3/h) at 1450 rpm on 50 Hz.
02What is the HJ4197 made of?
The casing, head and relief valve are stainless steel to ASTM A743 Grade CF8M, with a 770 stainless alloy idler and carbon graphite bushing.
03Which ports does the HJ4197 have?
It has 1 1/2 inch ports with Class 150 flanges, like the HL4197 and the HJ4197-SEP1 version.
04What is the difference between the 4197 and the 4197-SEP?
The SEP version uses fluorosilicone and low temperature materials for minus 95 to plus 225 F service and is tested on food grade liquids.
05How heavy is the HJ4197?
The catalog shipping weight with relief valve is approximately 50 lb (23 kg).