Brand:

Viking Pump AS895 Cast Iron Mag Drive Internal Gear Pump

Description

Overview

Moving 35 GPM (8 m3/h) of fuel or lube oil through a pump with no shaft seal at all is what Viking Pump AS895 is made to do. It is a cast iron internal gear pump of the 895 mag drive series, with 2 1/2 inch ports, a speed rating of 1200 rpm and a pump weight of about 78 lb (35 kg) before the coupling and driver. The magnetic coupling passes torque through a 316L stainless canister, so the liquid and its vapour stay inside the casing. Seven Star LLC is an independent supplier serving Oman and the GCC.

The larger frame of the 895 series

Between HL and AS the pump changes frame: the port size grows, the idler and rotor become ductile iron, and the speed rating drops to 1200 rpm. In the AS the rotor and idler options are listed in the catalog as ductile iron to ASTM A536 Grade 60-40-18, a stronger material than the plain cast iron used in the smallest sizes. The casing and head stay cast iron to ASTM A48 Class 35B. The result is a robust pump for hydrocarbon transfer and lubrication services where cast iron is acceptable and sealless containment is wanted.

Viking Pump AS895 specification table

Parameter Value
Model Viking Pump AS895, series 895, cast iron mag drive, catalog section 1443
Port size 2 1/2 inch (65 mm)
Nominal rating (100 SSU and below) 35 GPM (8 m3/h) at 1200 rpm
Magnetic coupling MD-B (40 ft-lb, 54 Nm) or MD-C (80 ft-lb, 108 Nm)
Casing and head Cast iron, ASTM A48 Class 35B
Rotor Ductile iron, ASTM A536 Grade 60-40-18
Idler PPS composite standard
Rotor shaft and idler pin Hardened steel, ASTM A108 Grade 1045
Bushings Carbon graphite standard; hardened cast iron or silicon carbide optional
Relief valve Cast iron, ASTM A48 Class 35B
Canister 316L stainless steel
Magnets Neodymium iron boron standard; samarium cobalt optional
O-rings FKM standard
Maximum hydrostatic pressure 400 PSIG (28 bar)
Series operating pressure 125 PSI (8.5 bar)
Series temperature range minus 60 to 500 F (minus 50 to 260 C); standard magnets limit the pump to 225 F
Series viscosity range 28 to 25,000 SSU (1 to 5,500 cSt)
Approximate pump weight, less power about 78 lb (35 kg)

How Viking Pump AS895 sits beside AK895 and AL895

All three have the same frame weight of 78 lb and a 1200 rpm rating. The Viking Pump AS895 delivers 35 GPM through 2 1/2 inch ports. The AK895 delivers 50 GPM (11 m3/h), also with 2 1/2 inch ports, and the AL895 delivers 75 GPM (17 m3/h) with 3 inch ports. Because the AS has the smallest displacement it needs the lowest coupling torque and often fits the MD-B coupling, while the larger pumps may need the MD-C.

Where it works best

  • Fuel and distillate transfer in terminals and depots.
  • Lube oil systems for compressors and turbines.
  • Heat transfer oil and hydraulic fluid circulation.
  • General industrial liquids that are compatible with cast iron.

Coupling selection and weights

The MD-B coupling is rated at 40 foot-pounds (54 Nm) and ships at about 71 lb (32 kg); the MD-C is rated at 80 foot-pounds (108 Nm) and ships at about 95 lb (43 kg). Combined with the 78 lb pump, an assembled unit is heavy, so the base and lifting plan must allow for it. Select the coupling from the torque calculation in the catalog, and keep a margin on the lowest operating temperature where viscosity is highest.

Limits

Series operating pressure is 125 PSI (8.5 bar), hydrostatic limit is 400 PSIG (28 bar), and viscosity ranges from 28 to 25,000 SSU (1 to 5,500 cSt). Standard magnets restrict the pump to about 225 F (105 C), while samarium cobalt magnets allow the higher series range up to 500 F (260 C). The pump can run in either direction, and the relief valve must point to the suction port.

Installation tips

Lift the pump and coupling with a strap, set them on a stiff base, and align after connecting the pipework. Flush new carbon steel pipes before connecting the pump, since rust and weld debris collect on the magnets. A strainer in the suction line is advised. Fill the pump, check the rotation and start against an open discharge.

Maintenance

Plan to inspect bushings and thrust washers regularly, and replace carbon graphite parts when worn. Keep an O-ring kit at hand, check the relief valve spring and keep a record of motor current. Avoid dry running and starting against a closed valve.

Fuel and lube oil duties in more detail

At terminals and depots a pump like the Viking Pump AS895 often serves as a transfer or loading pump where fuel vapour must not be released. Because the liquid is contained, there is no seal flush and no seal leak to collect, which simplifies hazardous area compliance. In lubrication systems it may circulate oil through coolers and filters continuously, and the sealless design avoids the slow weeping of a seal that can foul a skid. The same pump may serve a different liquid in the future, so record the viscosity range for each service in your pump file.

Commissioning checklist

  • Flush new pipework and fit a strainer before connecting the pump.
  • Check coupling alignment and the clearance of the outer magnet.
  • Fill the casing, vent air and confirm the relief valve points to suction.
  • Start against an open discharge and watch motor current and noise.
  • Record running current and temperature as a baseline.

Spare parts to carry

A set of carbon graphite bushings, thrust washers and FKM O-rings covers most overhauls. For critical duty, keep a spare idler and a relief valve spring. When ordering parts, quote the complete model string from the nameplate, because the letters after the series number identify the coupling and drive unit. The Viking Pump AS895 weighs about 78 lb without coupling, so plan the lifting method for maintenance in advance.

Cast iron or stainless

If the liquid is corrosive, wet or has chlorides, the stainless version of this pump, the AS897, is a better match. For clean hydrocarbons, oils and similar liquids, cast iron remains the economical choice and has a long history in Viking pumps.

Related items you may also need: NETZSCH NOTOS 2NS Two Screw Pump | KRACHT KF80RF2-D15 Gear Pump | KRACHT KF 4/150 G10B N00 7DP1 Transfer Gear Pump | All Viking Pump products.

Viking Pump AS895 ordering checklist

  • When the Viking Pump AS895 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
  • Every enquiry for the Viking Pump AS895 is answered with a written confirmation of the code and expected lead time.
  • Use the attached datasheet to check the Viking Pump AS895 ratings, dimensions and connection details against your drawings.

Documents and quotation

The Viking catalog section for the 895 series is attached, with the dimension tables for the AS, AK and AL sizes. To obtain a quotation on Viking Pump AS895, send the quantity, liquid, temperature, pressure, coupling and drive details, and the delivery location in Oman or the GCC.

Other Models in the Viking 895 Range

Seven Star LLC supplies models from the Viking 895 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Viking Pump HJ895 Cast Iron Mag Drive Internal Gear PumpPositive Displacement PumpsView details
Viking Pump AS895 Cast Iron Mag Drive Internal Gear PumpPositive Displacement PumpsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Viking Pump AS895 Cast Iron Mag Drive Internal Gear Pump Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is the American maker of positive displacement pumps best known for the internal gear pump, often described as the "gear-within-a-gear" design. The principle goes back to Jens Nielsen, a Danish-born quarry owner in Cedar Falls, Iowa, who needed a better way to drain water from his quarry and patented his internal gear pump in 1904. In 1911 Nielsen and three local partners formed the Viking Pump Company in Cedar Falls, which is still the company's home. Viking has been part of IDEX Corporation since 1989.

Viking Pump company profile

Founded 1911, Cedar Falls, Iowa, USA, by Jens Nielsen with P.C. Petersen, W.L. Hearst and George Wyth
Headquarters Cedar Falls, Iowa, USA
Ownership A unit of IDEX Corporation since 1989
Core technology Internal gear pumps (rotor, idler gear and crescent), plus external gear, vane, lobe and circumferential piston pumps
Typical liquids Viscous and difficult liquids: fuel and lube oils, asphalt and bitumen, resins, polymers, chemicals, ammonia, molasses, inks and adhesives
Standards API 676 versions for refinery and petrochemical service; jacketed and heated versions for liquids that must be kept hot

Milestones

  • 1904: Jens Nielsen patents his internal gear pump design.
  • 1911: Viking Pump Company is founded in Cedar Falls, Iowa.
  • 1989: Viking becomes part of IDEX Corporation.
  • 2011: Viking marks 100 years in Cedar Falls.
  • Today: Internal and external gear pumps, mag drive pumps and API 676 pumps sold through distributors worldwide.

How a Viking internal gear pump works

An internal gear pump has two moving parts: an outer rotor gear and a smaller idler gear that turns inside it, offset on a pin. A crescent-shaped partition on the head fills the space between them. As the gears come out of mesh on the suction side, liquid fills the opening tooth spaces, is carried around both sides of the crescent and is pushed out as the teeth mesh again on the discharge side. Flow is smooth and almost proportional to speed, so the same pump can handle thin solvents or very thick liquids. The pump is reversible, and an internal relief valve is often fitted to protect it if the discharge is blocked. For thick liquids, choose a larger pump at a lower speed; for hot products such as asphalt, choose a jacketed or heated version.

Where Viking pumps are used in Oman and the GCC

In the region, Viking pumps move fuel oil, lube oil and base oils in refineries and terminals, bitumen and asphalt in road-building and storage plants, resins and chemicals in petrochemical plants, and ammonia in refrigeration systems. External gear pumps such as the GB series are used for chemical injection into pipelines, and mag drive pumps are chosen where a seal leak is not acceptable.

Viking Pump models we list

Family Examples
General-purpose internal gear pumps KK124C, H1124C O-Pro, QS124C, M124A, N324A, RS4324A
Jacketed and heated pumps KK224C, Q224C, M224A, KK124E asphalt
Steel and stainless steel pumps L123C, QS4123C, RS4323A, KK127C, Q4127C
API 676 pumps LS4223AX, Q4223AX, N4323AX, R4323AX, KK4223AA
Motor speed, external gear and mag drive pumps HL495, AK4195, GB-41013, GB-41430, SG-0741, AK893 mag drive
Special-duty pumps KK4924A ammonia, KK4624C abrasive, LVP41027 vane

Ordering Viking pumps: what we need

Send the full model number and serial number from the nameplate. The letters at the start of the model (for example G, H, KK, LS, Q or RS) give the pump size, and the digits give the construction, seal and material. For a new pump, tell us the liquid, its viscosity and temperature, the flow rate, the discharge pressure, the port size and whether you need a jacket, a relief valve, a motor and baseplate, or API 676 construction. For spares, send the model and serial number and say whether you need the rotor, idler, idler pin, bushing or seal kit.

Facts checked against Viking Pump and IDEX company history and published Viking product catalogues, November 2026.

FAQ

Questions about the Viking Pump AS895 Cast Iron Mag Drive Internal Gear

Answers from our engineering team on installation, compatibility and integration.

01What flow does the Viking Pump AS895 deliver?
The catalog rating is 35 GPM (8 m3/h) at 1200 rpm on liquids of 100 SSU and below.
02What are the AS895 port sizes?
The catalog lists 2 1/2 inch ports for the AS895, the same as the AK895, while the AL895 has 3 inch ports.
03Which couplings fit the AS895?
The MD-B coupling at 40 ft-lb (54 Nm) and the MD-C coupling at 80 ft-lb (108 Nm) are listed for the AS size.
04How heavy is the AS895?
The pump less power weighs about 78 lb (35 kg); the MD-B coupling adds about 71 lb and the MD-C about 95 lb.
05Does the AS895 use a mechanical seal?
No. It is a sealless pump with a magnetic coupling through a 316L stainless steel canister.