- Automation & ControlView all 3,161 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Victaulic
Victaulic Style 732H FireLock Wye Type Vic-Strainer DN50-DN100
Description
Overview
Victaulic Style 732H is the FireLock wye-type Vic-Strainer, a grooved strainer with a straight-through flow path that gives a lower pressure drop than a Y-body with a sharply turned basket. It is installed with two Victaulic couplings, it is made in sizes 2 to 4 inch (50 to 100 mm) and every size is rated up to 365 psi (2500 kPa) working pressure. A durable 304 stainless steel perforated basket is standard.
The datasheet lists perforation sizes: 0.062 inch holes for the 2 to 3 inch sizes and 0.188 inch holes for the 4 inch size. These holes catch scale, weld spatter and debris that would otherwise block sprinkler heads, deluge nozzles or small orifices.
Seven Star LLC is an independent supplier serving Oman and the GCC.
Data table for Victaulic Style 732H
| Parameter | Value |
|---|---|
| Product | Wye-type grooved strainer, FireLock |
| Sizes | 2, 2 1/2, 3 and 4 inch / 50 to 100 mm |
| Maximum working pressure | 365 psi / 2500 kPa for all sizes |
| Basket | 304 stainless steel, perforated |
| Perforation, 2 to 3 inch | 0.062 inch diameter holes |
| Perforation, 4 inch | 0.188 inch diameter holes |
| 2 inch end to end | 9.75 inch / 248 mm; weight 10.0 lb / 4.5 kg |
| 2 1/2 inch end to end | 10.75 inch / 273 mm; weight 14.0 lb / 6.4 kg |
| 3 inch end to end | 11.75 inch / 299 mm; weight 20.0 lb / 9.1 kg |
| 4 inch end to end | 14.25 inch / 362 mm; weight 32.0 lb / 14.5 kg |
| Connections | Two Victaulic grooved couplings |
| Dimension note | 3 inch listed for both 88.9 mm and 76.1 mm outside diameter pipe |
Why a wye strainer
A wye body angles the basket away from the main flow, so the water follows a nearly straight path through the body and the basket can be removed through the side branch for cleaning. That is why the datasheet describes straight-through flow and lower pressure drop. In a fire pump suction or a sprinkler riser, lower pressure drop leaves more pressure available for the sprinklers.
Applications in Oman and the GCC
Typical places are sprinkler risers fed from tanks where silt or rust scale can build up, deluge and foam systems with small nozzles, pump suction or discharge lines, and plant water systems with sensitive control valves. In new construction, strainers catch the welding debris and pipe scale that travel down the line after flushing, and in older systems they protect equipment after maintenance.
Selecting Victaulic Style 732H
Pick the size to match the pipe, and decide if the standard perforation is acceptable. A 0.062 inch hole gives fine screening on 2 to 3 inch sizes, but it clogs faster in dirty water than the 0.188 inch hole used on the 4 inch size. The datasheet is an older revision, so confirm the full order code before ordering and mention if a different basket is wanted. The valve must be installed with the flow arrow in the right direction and the basket cap at the bottom side.
How Style 732H differs from Series 732 and other strainers
Victaulic Style 732H belongs to the FireLock group and has a 365 psi rating on all sizes, with end-to-end lengths growing from 9.75 inch at 2 inch to 14.25 inch at 4 inch. Its distinguishing feature is the wye body, and it should be chosen where a straight-through path and a high pressure rating are both needed on 2 to 4 inch lines.
Installation
Depressurise and drain the system. Install the grooved couplings, align the strainer body with the arrow in the flow direction, and leave room under the cap to withdraw the basket. Support the strainer body so that the weight is not carried by the couplings. After filling, vent air and check for leaks.
Maintenance
Open the cap on a regular schedule, remove the basket, clean out debris and look for torn mesh. Replace damaged baskets rather than patch them. Record cleaning dates and the amount of debris caught, since an increase signals corrosion upstream.
Cleaning schedule guidance
New systems are usually cleaned after the first week of service, again after the first month and then at each annual inspection. A strainer that is cleaned only when the system fails will often be found packed hard, and the pressure drop in the meantime may reduce the flow to the sprinklers. Mark the strainer location on the as-built drawings and add it to the inspection checklist so that fire protection contractors know where it is. Isolate and drain the section before opening the cap, and make sure the cap seal is intact when closing it.
Strainer location and orientation
Install the strainer on a horizontal run with the cap pointing down, or on a vertical pipe with the flow arrow pointing downward, depending on the instructions, so that debris falls into the basket and not back into the line. Leave at least the basket length of free space below the cap, and place a small drain valve nearby if the line cannot be drained easily. Ensure that the strainer is upstream of equipment it is protecting, such as pumps, control valves and meters.
For fire protection lines, confirm with the designer and the authority having jurisdiction that the strainer position is shown on the approved drawings, and record its size and basket perforation in the system documentation so that inspectors can verify the installed device against the design and the maintenance team knows which basket to order when a replacement is required.
Pressure drop considerations
A clean strainer causes only a small pressure loss, but a half-blocked basket may cause a large one. Add the strainer in the hydraulic calculation using an equivalent length from the manufacturer’s data and keep a margin for partial fouling. Where the system pressure is close to the limit of a pump or a sprinkler design, regular cleaning is the best protection.
Related items you may also need: Victaulic Series 761 Vic-300 MasterSeal Butterfly Valve | Victaulic FireLock Series 705 Butterfly Valve, Supervised Open | Victaulic Style 77 Standard Flexible Coupling | All Victaulic products.
Checklist before ordering the Victaulic Style 732H
- Before ordering the Victaulic Style 732H, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
- Our team confirms the Victaulic Style 732H code, condition and lead time in writing before any order is placed.
- The datasheet attached to this page is the reference for the Victaulic Style 732H dimensions, ratings and wiring.
- The Victaulic Style 732H is listed in our pipes & fittings range and ships to sites across Oman and the GCC.
- Spare quantities of the Victaulic Style 732H are worth planning for critical duty so that a failure does not stop production.
Documents and quotation
The datasheet for Victaulic Style 732H, publication 10.68, is attached. Send your RFQ with the size, basket perforation and quantity, and we will confirm the order code with you.
Other Models in the Victaulic Grooved Couplings Range
Seven Star LLC supplies models from the Victaulic Grooved Couplings range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
Datasheets & Documents
- Datasheet Victaulic Style 732H FireLock Wye Type Vic-Strainer DN50-DN100 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Victaulic is an American maker of grooved mechanical pipe joining systems, valves and fire protection products, headquartered in Easton, Pennsylvania. Its grooved coupling was patented in 1919 by Ernest Tribe, and the name combines 'victory' and 'hydraulic'. Victaulic is privately held and reinvests in its own plants and technology.
Seven Star LLC lists Victaulic couplings and butterfly valves, among them the Style 107N QuickVic rigid coupling, and supplies Victaulic couplings and fittings for mechanical, utility and process piping in Oman on inquiry.
Victaulic company profile
| Origins | 1919, grooved coupling patent |
|---|---|
| Name | From 'victory' and 'hydraulic' |
| Headquarters | Easton, Pennsylvania |
| Ownership | Privately held |
| Product families | Style 07, 77 and 107N grooved couplings, Vic-300 MasterSeal butterfly valves, FireLock fire protection valves and sprinklers, grooved fittings and tools |
Milestones
- 1919: The grooved Victaulic coupling is patented.
- 2019: Victaulic marks 100 years.
Victaulic Style 107N QuickVic couplings
The Style 107N is a rigid coupling for roll-grooved or cut-grooved carbon steel and stainless steel pipe in sizes from 2 to 12 inches (DN 50 to DN 300). Victaulic rates it from full vacuum up to 750 psi (5171 kPa), but the working pressure of a given joint depends on pipe material, wall thickness and size. The housing has an angled bolt pad that makes the joint rigid, and a galvanized finish is optional.
Where Victaulic couplings are used and what to send
The manufacturer names HVAC, utility and process piping as the applications for this style. For an inquiry, send the style number, nominal size, pipe material and schedule, the fluid and temperature so the gasket grade can be checked, the housing finish and the quantity. GCC consultants often ask for the submittal sheet, which we provide from the manufacturer.
Facts checked against Victaulic's 100-year innovation timeline, October 2026.
Browse Victaulic products by category: Pipes & Fittings.
Victaulic products we list
FAQ
Questions about the Victaulic Style 732H FireLock Wye Type Vic-Strainer
Answers from our engineering team on installation, compatibility and integration.
01What sizes does Victaulic Style 732H come in?
2, 2 1/2, 3 and 4 inch (50 to 100 mm), all with grooved ends for Victaulic couplings.
02What is the pressure rating of Style 732H?
All sizes are rated to 365 psi (2500 kPa) maximum working pressure.
03What basket does Style 732H use?
A 304 stainless steel perforated basket with 0.062 inch holes on 2 to 3 inch sizes and 0.188 inch holes on 4 inch.
04Why choose a wye type strainer?
It provides straight-through flow for a lower pressure drop, and the basket can be removed from the branch for cleaning.
05How is Style 732H installed?
With two Victaulic couplings, the flow arrow in the flow direction and room to remove the basket.


















Reviews
There are no reviews yet.