Brand:

Verder VF40 Verderflex Peristaltic Hose Pump, 1.25 l/rev, 40 mm

Description

Overview

The Verder VF40 is where the Verderflex range moves from light process duty to genuine industrial transfer. It displaces 1.25 litres with every revolution of its rotor, and the data sheet gives a capacity of 75 litres per hour for each revolution per minute, which means that a speed of 40 rpm delivers 3,000 litres per hour and the top of the plotted range at 100 rpm corresponds to 7,500 litres per hour. The ports are 40 mm (1.5 inch) and carry a 304 stainless steel universal slotted flange that fits DIN PN16, ANSI 150 and JIS 10K.

This is a cast iron machine with a carbon steel front cover and a Perspex inspection window, built to run on a heavy base frame at low shaft speed. Low speed is the reason hose pumps last: the hose is squeezed only a few dozen times each minute, so it flexes gently compared with a diaphragm or piston pump.

Seven Star LLC is an independent supplier serving Oman and the GCC. The following description is based on the manufacturer techno sheet and is meant to help specify the exact model code.

What the VF40 performance curve shows

The curve plots the absorbed power of the pumphead against speed for discharge pressures of 0, 7.5, 10 and 15 bar, and the minimum starting torque is 320 Nm. At 15 bar and full speed the power demand approaches the upper end of the 4 kW scale printed on the chart, so the gearmotor must be chosen with the highest pressure in mind and not just the average duty.

A shimming curve plots pressure against speed for different shim counts. The note under it says that for product temperatures over 65 degrees Celsius or viscosities over 2,000 mPas, one shim less than shown should be fitted. Flows are quoted for water at 20 degrees Celsius without suction lift or discharge pressure and will fall with viscous products, long suction lines or high vacuum.

Technical specifications of the Verder VF40

Parameter Value
Model Verderflex VF40
Displacement 1.25 litres per revolution
Capacity speed (rpm) x 75, in litres per hour
Pressure lines on curve 0, 7.5, 10 and 15 bar
Minimum starting torque 320 Nm
Port size 40 mm (1.5 inch)
Port flange 304 stainless steel, universal slotted: DIN PN16, ANSI 150, JIS 10K
Inserts 316L stainless steel; options polypropylene, PVDF
Housing / rotor Cast iron (GG25) / cast iron (GG25)
Rotor shoes Aluminium (6082T6)
Front cover Carbon steel with Perspex window
Hose Natural rubber; options NBR, NBRF, EPDM, CSM
Lubricant Verderlube or Verdersil
Frame Carbon steel, powder coated
Typical unit weight 273 to 295 kg
Plotted speed range up to 100 rpm

How VF40 differs from other Verderflex VF sizes

Next to the VF25, the Verder VF40 offers 1.25 litres per revolution instead of 0.28, ports of 40 mm instead of 25 mm and a start torque of 320 Nm instead of 115 Nm. The unit weight rises from 101 to 144 kg to 273 to 295 kg, which has consequences for the foundation and for lifting during hose changes.

Going up to the VF65 brings 5.67 litres per revolution and a unit weight of 879 to 910 kg. If your required flow sits between two sizes, choose the larger pump running slower, as the slower speed reduces hose wear and heat.

Typical applications in Oman and the GCC

This model fits mid-volume transfer of abrasive and viscous products: sludge to dewatering equipment, lime and cement slurries, mineral concentrates, paints, pigments and food pastes. In municipal and industrial water treatment it is used for dosing coagulants and for moving thickened sludge, while in oil and gas service yards it transfers mud, cuttings slurry and chemical additives.

The cast iron body tolerates the knocks of a busy industrial site, and the transparent window allows an operator to see hose condition and lubricant level during rounds. Select the hose material for the chemical and the temperature before ordering.

Foundation, drive and piping for Verder VF40

With a unit weight of 273 to 295 kg, plan a flat concrete plinth and lifting points for installation. The gearmotor must produce at least 320 Nm to start the pump and enough running torque for the highest pressure. A variable speed drive lets the flow follow the process and gives a soft start that protects the hose.

Run suction pipework short, straight and at least the port size, avoiding high points where gas can collect. Discharge lines need a pressure relief device or a pressure switch, as a blocked line can raise pressure beyond the design limit. Use flexible connections so the ports carry no pipe loads, and consider a pulsation dampener when a steady flow matters.

Servicing the VF40 pump

Change the hose at planned intervals, based on running hours, pressure and product aggressiveness, and inspect the lubricant for product contamination, which signals hose leakage. Check the rotor shoes and shims when the hose is removed and clean the pumphead before refilling with the correct quantity of lubricant.

Keep a spare hose and lubricant on site, and record the hose compound used when ordering. When asking for spares, quote the pump designation VF40 and the hose material.

Operating habits matter as much as hardware. Avoid starting against a closed discharge valve, avoid running at the highest speed with the thickest product for long periods, and give the pump rest when the data sheet’s intermittent duty guidance applies. A pump that is allowed to cool between heavy duties will deliver noticeably more hose life than one that is pushed continuously to its limits, and the savings in spare hoses repay a modest increase in pump size very quickly.

Related items you may also need: VERDERAIR VA50 Metallic Air-Operated Double Diaphragm Pump | Verderflex Rapide Peristaltic Tube Pump | VERDERAIR PURE VA-P40 Chemical Diaphragm Pump | All Verder products.

Documents and quotation

The manufacturer techno sheet for the Verder VF40 is attached to this page and carries the materials table, weights, performance curve and shimming curve.

Send your RFQ with the part number VF40, the quantity, the fluid and the delivery location in Oman or the GCC. Seven Star LLC will check availability of the Verder VF40, and spare hoses can be quoted together.

Other Models in the Verderflex VF Range

Seven Star LLC supplies models from the Verderflex VF range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Verder VF15 Verderflex Peristaltic Hose Pump, 0.083 l/rev, 15 mmPositive Displacement PumpsView details
Verder VF25 Verderflex Peristaltic Hose Pump, 0.28 l/rev, 25 mmPositive Displacement PumpsView details
Verder VF40 Verderflex Peristaltic Hose Pump, 1.25 l/rev, 40 mmPositive Displacement PumpsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Verder VF40 Verderflex Peristaltic Hose Pump, 1.25 l/rev, 40 mm Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Verder is a Dutch family-owned group of pump and laboratory equipment companies, founded in 1959 by André Verder in Vleuten, near Utrecht, as a distributor of industrial pumps. It expanded into Belgium in 1970 and Germany in 1973 and later developed its own pump brands, including VERDERAIR diaphragm pumps and Verderflex peristaltic pumps. The group is run by his son Andries Verder and has sales offices in 24 countries.

Seven Star LLC lists Verder pumps from both families and supplies them, with wear parts such as hoses and diaphragms, to process plants in Oman.

Verder company profile

Founded 1959, Vleuten, Netherlands
Founder André Verder
Ownership Verder family
Divisions Verder Liquids and Verder Scientific
Product families VERDERAIR air-operated double diaphragm pumps, VERDERAIR PURE chemical pumps, Verderflex Dura hose pumps and Rapide tube pumps, Packo centrifugal pumps

Milestones

  • 1959: André Verder starts the business.
  • 1970: Verder opens its first foreign subsidiary in Belgium.
  • 1989: Verder acquires Retsch.

Verderflex and Verderair pumps listed here

The Verderflex Dura 35 is a peristaltic hose pump, and the Verderflex Rapide is a low-pressure peristaltic tube pump from the same family. The Verder VA25 is a Verderair air-operated double diaphragm pump. The VA25 is offered in metallic and non-metallic versions.

Where Verder pumps are used

In hose pumps such as the Dura, the liquid touches only the hose. Diaphragm pumps such as the VA25 are used for liquid transfer and for emptying containers.

Verder products we list

Family Examples
Pumps VA25 Air-Operated Double Diaphragm Pump, VERDERAIR PURE VA-P40 Chemical Diaphragm…, VERDERAIR VA50 Metallic Air-Operated Dou…, Verderflex Dura 35 Peristaltic Hose Pump, Verderflex Rapide Peristaltic Tube Pump

Ordering Verder pumps and parts: what we need

Send the pump type code and serial number from the nameplate. For a Verderflex hose, state the pump size and the hose material. For a Verderair pump, state the body, diaphragm, ball and seat materials. For a new pump, give the liquid, flow, pressure and temperature. We quote for buyers across the GCC.

Facts checked against Verder's own company roots page (verder.com), October 2026.

FAQ

Questions about the Verder VF40 Verderflex Peristaltic Hose Pump, 1.25

Answers from our engineering team on installation, compatibility and integration.

01What flow does the Verder VF40 deliver per revolution?
It displaces 1.25 litres per revolution, so capacity in litres per hour equals pump speed in rpm multiplied by 75.
02What starting torque does the Verder VF40 require?
The data sheet states a minimum starting torque of 320 Nm.
03What port size and flange does the Verder VF40 have?
It has 40 mm (1.5 inch) ports with a 304 stainless steel universal slotted flange for DIN PN16, ANSI 150 and JIS 10K.
04What is the weight of the Verder VF40?
A typical unit weighs 273 to 295 kg depending on the configuration, so plan lifting gear for hose changes.
05When should one shim less be used on the Verder VF40?
For product temperatures above 65 degrees Celsius or viscosity above 2,000 mPas the data sheet advises one shim less than the curve shows.