Brand:

Bürkert 221862 Type 6281 Brass Solenoid Valve G1 1/2 DN40 24 V DC

Description

Overview

When a process line needs real flow but still wants a small solenoid on top, a large servo valve such as Bürkert 221862 is the answer. It is the DN40 brass version of Bürkert Type 6281, with a G1 1/2 internal thread, a 40 mm orifice and a water Kv of 30 cubic metres per hour. It is a normally closed 2/2-way valve driven by a 24 V DC coil, and it is built for pressures from 0.2 up to 16 bar, with NBR seals and a polyamide coil. Seven Star LLC is an independent supplier serving Oman and the GCC.

Bürkert 221862: size and weight in practice

At 3.0 kg, the 221862 valve is far heavier than the G1/2 sizes, and that matters during design. The pipework either side should be supported, because the thread alone should not carry the mass of valve and coil in a vibrating plant. The G1 1/2 port is common on headers feeding sprinkler zones, cooling-water branches, tank fill lines and air-conditioning plant. The article is the version without the manual override, which keeps the housing simple, and its coil is the 32 mm class with 9.5 W cold power at 24 V DC.

Specification of 221862

Specification Value
Article number 221862
Function 2/2-way, servo-controlled, normally closed (CF A)
Body brass
Port connection G1 1/2
Orifice 40 mm
Kv value (water) 30 m3/h
Pressure range 0.2 to 16 bar
Weight 3.0 kg
Seal and coil NBR, polyamide coil
Medium temperature minus 10 to plus 80 degrees C
Supply voltage 24 V DC, plus or minus 10 percent
Coil power, DC 9.5 W cold, 8 W warm
Switching time (family) opening 0.1 to 1.5 s; closing 0.2 to 4 s
Plug Type 2518 form A to DIN EN 175301-803, separate
Protection IP65 with cable plug
Duty 100 percent continuous operation

How 221862 differs from other Type 6281 variants

Two other brass versions share the 40 mm orifice but have different Kv values: the G1 1/4 valve flows 23 m3/h at 2.7 kg, and the G2 valve matches the G1 1/2 valve at 30 m3/h but weighs 3.2 kg. The article here sits between them. At the small end, the DN10 valve with a G1/4 thread flows 1.5 m3/h at 0.43 kg, and the largest DN50 sizes reach 40 m3/h at over 4 kg. Voltage variants 24 V 50 to 60 Hz and 230 V carry the next two article numbers, and a manual override variant has an entirely separate code.

Application scenarios

Think of a cooling-tower make-up line, where a level controller opens a 40 mm valve to refill a basin; of a wash-down header in a food plant; of a fire-water test line or a heat-exchanger bypass. Gulf plants also use this valve class on instrument air receivers for large condensate discharge, and on industrial boilers for feedwater control. Servo-assisted operation allows a relatively small coil to switch large cross-sections, but the line must hold the necessary pressure difference while the valve opens.

Compatibility checks

Verify the following: line pressure at least 0.2 bar above downstream pressure; a medium compatible with brass and NBR; a maximum temperature of 80 degrees C; a 24 V DC control source of at least 9.5 W per valve; and a free thread of G1 1/2 on both pipe stubs. If the medium is seawater or contains chloride, consider a stainless steel body from the same family. If you require override operation to be possible during commissioning, order the version that includes one instead.

Pressure difference and servo action

The principle behind this valve explains its limits. A small pilot opening in the diaphragm is released by the coil, and the pressure on the upstream side then lifts the main seat. That is why the 0.2 bar minimum matters: below it the diaphragm cannot be lifted reliably. At the upper end the valve is rated to 16 bar, which covers most municipal and industrial water systems in the region. Because the opening time of up to 1.5 seconds and closing time of up to 4 seconds are comparatively slow, the valve is gentle on piping, but it is not the right choice for fast pulsing or dosing duties, for which direct-acting valves from the same maker are better.

Electrical supply planning

A 24 V DC valve of this size consumes up to 9.5 W, so a bank of ten of them needs roughly 95 W at the moment of energising. Size the power supply and the PLC output relays with that in mind, and use a protection diode or a plug with varistor to suppress switch-off spikes if the output is a transistor type. The coil supports continuous energising, which is the normal state for lines that remain open through a shift.

Fitting and commissioning

Support the pipework, apply sealant, and tighten the valve by wrench on the body flats only. Follow the arrow, and install the valve with the coil upright where possible. A strainer in front of the valve protects the servo pilot channel. After connection of the plug, open the supply slowly, flush the line and test that the valve opens and closes without hammer. Because closing times can reach four seconds, pressure surges are modest, though they should still be checked in long lines.

Keeping it in service

Inspect the strainer, look for external leakage around the cover, and check coil temperature after long energised periods; a warm coil is normal, but a very hot one suggests wrong voltage. For most plants an exchange of the complete valve is the quickest remedy when a fault cannot be cleared by cleaning.

Ordering Bürkert 221862

Provide the quantity, the control voltage, and whether cable plugs are needed. We will check the order code against your pipe thread and operating conditions before quoting.

When requesting a quotation for Bürkert 221862, quote the full Bürkert 221862 designation from the nameplate or order code so the correct variant is matched, and mention the plant tag if the unit replaces an installed device.

Related items you may also need: Bürkert 178275 Type 6027 Stainless 2/2-Way Plunger Valve | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert 221602 Type 6213 Servo-Assisted 2/2-Way Solenoid Valve | All Bürkert products.

Documents and quotation

The manufacturer data sheet for Type 6281 is attached here and carries the dimensions, circuit diagram and complete ordering chart. For a quotation, send an RFQ with the part number Bürkert 221862, the quantity and your delivery point in Oman or the GCC, and we will reply with availability and lead time.

Other Models in the 6281 Range

Seven Star LLC supplies models from the 6281 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 221844 Type 6281 Brass 2/2-Way Solenoid Valve G1/2 24 V DCSolenoid ValvesView details
Bürkert 221862 Type 6281 Brass Solenoid Valve G1 1/2 DN40 24 V DCSolenoid ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 221862 Type 6281 Brass Solenoid Valve G1 1/2 DN40 24 V DC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 221862 Type 6281 Brass Solenoid Valve G1

Answers from our engineering team on installation, compatibility and integration.

01What is Bürkert 221862?
Bürkert 221862 is a Type 6281 brass, servo-controlled, normally closed 2/2-way solenoid valve with a G1 1/2 thread and 40 mm orifice.
02What flow does 221862 provide?
The 221862 valve has a Kv value of 30 m3/h for water and a pressure range of 0.2 to 16 bar.
03What coil does Bürkert 221862 use?
It uses a 24 V DC polyamide coil of 32 mm class, drawing 9.5 W cold and 8 W warm, with NBR seals.
04Is there a manual override on 221862?
No, 221862 is the version without a manual override; the override versions are listed under other article numbers in the data sheet.
05How heavy is Bürkert 221862?
The data sheet gives 3.0 kg for this G1 1/2 valve, so support the pipework on both sides during installation.