Brand:

Pizzato CS FS-11V024 Safety Timer, Delay at Energising

Description

Overview

Most safety relays react as quickly as they can. The Pizzato CS FS-11V024 does the opposite on purpose: it is a safety timer that waits before it closes its safety contact. Pizzato designed the CS FS-1 series as a module with a delay at energising, so that a release command for an interlocked guard is given only after a defined time. This code has delay range 1, an adjustable time of 0.3 to 3 seconds in 0.3 second steps, a 24 V ac/dc supply and screw terminals. Its outputs are one normally open safety contact and two normally closed signalling contacts. Seven Star LLC is an independent supplier serving Oman and the GCC.

How a delay at energising is used

Picture a machine with a guard locked by a solenoid. When the operator asks to open the guard, the machine is told to stop, but the lock must not release until the motion has ended. The timer is energised by the stop command, counts down its time with a self-monitored and redundant timing circuit, and only then closes the safety contact that releases the lock. If the timing circuit fails, the contact does not close. This is the reverse of an off-delay module and it is the reason the catalogue describes the product as providing a release command for interlocked safety devices. The 0.3 to 3 second range is suited to drives that brake quickly.

Parameters of Pizzato CS FS-11V024

Parameter Value
Module type Safety timer, delayed contacts at energising
Delay code 1 0.3 to 3 s in steps of 0.3 s
Outputs 1NO safety contact, 2NC signalling contacts
Supply (024) 24 Vac/dc, 50 to 60 Hz, plus or minus 15 percent
Consumption Below 5 VA ac, below 2 W dc
Safety limits SIL 3, PL e, category 4 depending on circuit structure
Release time with supply lost Below 60 ms
Contact type Forcibly guided, silver alloy
Switching limit 230/240 Vac, 300 Vdc
Utilisation categories AC-15 230 V 3 A; DC-13 24 V 4 A
Ith and squared current 6 A per branch, 36 A2 total
Short circuit protection PTC, Ih 0.5 A, response over 100 ms, reset over 3 s
Fuse 4 A external
Insulation Ui 250 V, Uimp 4 kV
Temperature range Minus 25 to plus 55 degrees Celsius
Housing PA 66 V0, IP40, terminal strip IP20, design C

How Pizzato CS FS-11V024 differs from other CS FS-1 codes

The first digit after FS-1 selects the time scale. In the same family, a 12 code gives 1 to 10 seconds in 1 second steps, a 13 code gives 3 to 30 seconds in 3 second steps, and a 14 code gives 30 to 300 seconds in 30 second steps. Fixed time versions are written with an option such as TF0.5, TF1, TF3 or TF10. The supply and the terminals are chosen with the last characters: 024, 120 or 230 for the voltage, and V, M or X for screw terminals, connector with screw terminals or connector with spring terminals. The 11 code therefore has the finest steps and the shortest reach of the series.

Applications in Oman and the GCC

Typical customers are machine builders and maintenance teams who retrofit guard locking on woodworking machines, pipe cutting lines, textile and plastic equipment and packaging lines. The timer is also useful in test stands and in laboratories of universities where a door must stay locked for a few seconds after a drive stops. With the ambient limit of 55 degrees Celsius it belongs in a cabinet, not directly in the sun, and in summer the cabinet temperature of an outdoor panel needs checking.

Installation and wiring

Mount the module on a DIN rail, feed A1 and A2 with the supply, and arrange the circuit so that the module is energised when the release is requested, following the function diagrams in the catalogue. Wire the normally open safety contact in series with the lock release circuit and use the two normally closed contacts as feedback or signalling to the PLC. Limit the output current to the ratings above and use the 4 A fuse. The catalogue notes that the 24 V ac/dc version should be supplied from a Class 2 or limited energy source where the UL approval is relied upon, and that 60 or 75 degrees Celsius copper conductors of 30 to 12 AWG are to be used.

Timer or standard safety relay: a decision aid

Ask three questions before choosing. First, does the hazard outlast the stop command? If the machine is still moving after power is removed, a plain relay would release the guard too early and a timer is needed. Second, is the stopping time constant? A fixed time is more robust, but if the time depends on the load, an adjustable range is more convenient. Third, how many contacts are needed? This module gives one safety contact, so the Pizzato CS FS-11V024 is chosen for the release function of a lock or a valve, while the load disconnection is handled by another module with more contacts. When in doubt, discuss the stop time and the circuit with your safety engineer, and send us the drawing together with the RFQ so that we can recommend a matching module from the same catalogue.

Typical sequence of events

  1. The operator requests access and the control system commands the machine to stop.
  2. The drive brakes and the motion decays during the time you measured at commissioning.
  3. The timer is energised, counts its adjusted time of up to 3 seconds in this range, and its self-monitoring circuit checks itself.
  4. After the delay the safety contact closes and the lock releases, and the signalling contacts report the new state.
  5. When the guard is closed again, the circuit is reset and the cycle is ready for the next request.

Testing

Measure the real delay with a scope or a stopwatch after setting the dial, because a small error matters when the setting is short. Record it in the machine file. Repeat the check each year and after each exchange of the module. If the delay differs from the setting, replace the unit and do not rely on a re-adjustment alone.

Related items you may also need: Pizzato FR 1007 Position Switch, Adjustable Roller | Pizzato FK 301 Position Switch with Plunger, Snap Action | Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | All Pizzato products.

Checklist before ordering the Pizzato CS FS-11V024

  • Before ordering the Pizzato CS FS-11V024, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
  • Our team confirms the Pizzato CS FS-11V024 code, condition and lead time in writing before any order is placed.
  • The datasheet attached to this page is the reference for the Pizzato CS FS-11V024 dimensions, ratings and wiring.
  • The Pizzato CS FS-11V024 is listed in our safety switches & guard locking range and ships to sites across Oman and the GCC.
  • Spare quantities of the Pizzato CS FS-11V024 are worth planning for critical duty so that a failure does not stop production.

Documents and quotation

The catalogue sheet for the CS FS-1 timer module is attached to this page and contains the technical data, code structure, pin assignment and function diagrams. To get a quotation, send an RFQ with Pizzato CS FS-11V024, the quantity, the supply voltage of your cabinet and the destination in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Pizzato CS FS-11V024 Safety Timer, Delay at Energising Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.

Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.

Pizzato company profile

Founded 1984, Italy
Headquarters Marostica, Italy
Name since 1988
Catalogue More than 7,000 standard products
Product families FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches

Milestones

  • 1984: Pizzato is founded.
  • 1988: The company becomes Pizzato Elettrica.
  • 2019: A new headquarters opens in Marostica.

Pizzato product series

Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.

Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.

Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.

Where Pizzato switches are used

End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.

Pizzato products we list

Family Examples
Automation Accessories FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch

Ordering Pizzato switches: what we need

Send the full article code, or the actuator type, contacts, housing and cable entry.

Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.

FAQ

Questions about the Pizzato CS FS-11V024 Safety Timer, Delay at

Answers from our engineering team on installation, compatibility and integration.

01What delay can the Pizzato CS FS-11V024 be set to?
Delay code 1 gives an adjustable time of 0.3 to 3 seconds in steps of 0.3 seconds at energising.
02What outputs does the CS FS-11V024 provide?
One normally open safety contact and two normally closed signalling contacts, forcibly guided and made of silver alloy.
03Is the CS FS-11V024 an on-delay or off-delay module?
It is a safety timer with delayed contacts at energising, meaning the safety contact closes only after the set time has elapsed.
04What supply does the CS FS-11V024 use?
The 024 code uses 24 Vac/dc at 50 to 60 Hz with a tolerance of plus or minus 15 percent and below 5 VA ac or 2 W dc.
05Which safety levels does the CS FS-11V024 support?
Up to SIL 3 and PL e, with category 4 depending on the circuit structure, as stated in the catalogue.