Brand:

Panametrics Sentinel LCT4 Compact Ultrasonic Liquid Flowmeter

Description

Sentinel LCT4 compact high-accuracy liquid meter

The Panametrics Sentinel LCT4 is the compact successor to the original Sentinel LCT, built for high-accuracy measurement of crude oil, refined hydrocarbon products and other non-hydrocarbon liquids. The company redesigned the four-path ultrasonic body into a smaller, neater unit with integral cables, no extended buffers and no junction boxes, and the electronics are integrated with the flowcell in a single housing. The LCT4 is a multi-viscosity meter: proprietary algorithms keep it viscosity independent, so no prover run or setting change is required when the viscosity varies, and a single calibration curve covers the full range.

Highlights of LCT4

  • Linearity within plus or minus 0.15% of measured volume between 1 and 33 ft/s (0.3 and 10 m/s).
  • Uncertainty better than plus or minus 0.027% according to API MPMS 5.8.
  • OIML R117-1 Accuracy Class 0.3, NMi certificate TC7595; country-specific approvals available.
  • Pipe sizes 3 in to 24 in in 150, 300 and 600 lb flanges.
  • Laboratory calibration with one or several fluids to suit the application; no recalibration needed when transducers or electronics are replaced, as tested by NMi.
  • Integrated flow computer option for API 11.1 temperature and pressure volume corrections.

LCT4 technical specifications

Item LCT4
Viscosity and Reynolds 0 to 660 cSt; Reynolds above 10,000
Process temperature -40 to 140 C (-40 to 248 F)
Ambient / storage -40 to 60 C / -40 to 85 C
Body materials SA216 WCB carbon steel, SA352 LCB low-temperature carbon steel, SA351 CF8 (304) or CF8M (316) stainless steel
Schedules 40S, 80S, 10S, STD, XS
PED Category II, module B + C1
Installation Minimum 10D upstream with flow conditioner and 5D downstream
Electronics Epoxy aluminum or A351 stainless enclosure, IP66, 7 W, 100 to 240 VAC or 12 to 32 VDC
Outputs / inputs Two frequency/pulse outputs, two alarm relays, one 4-20 mA with HART; two 4-20 mA plus RTD or three 4-20 mA inputs
Interfaces HART, PanaLink over RS232/485/USB, Modbus RTU
Hazardous area Class I Div 1 B, C, D; ATEX II 2 G Ex d IIB+H2 (Ex de option); IECEx
Sample weights, 150 lb 4 in about 180 lb (82 kg); 12 in 582 lb (264 kg); 24 in 2112 lb (958 kg)

How LCT4 differs from LCT and LCT8

Against the original Sentinel LCT the LCT4 has a lower stated maximum viscosity (660 cSt versus 6600 cSt), a higher minimum Reynolds number (10,000 versus 5,000), a smaller size range (3 to 24 in versus 4 to 36 in), a process ceiling of 140 C instead of 120 C and a lighter body with integral cables. The 10D upstream requirement with flow conditioner replaces the 20D upstream of the LCT. Against the eight-path LCT8, the LCT4 has linearity of 0.15 percent rather than 0.12 percent, covers 3 in as well as 6 in, and needs longer straight runs.

Flow range examples for LCT4

The velocity window is 1 to 40 ft/s (0.3 to 12.2 m/s) as product capability. For a 6 in meter that corresponds to 20 to 818 m3/h, for 12 in 80 to 3203 m3/h, and for 24 in 301 to 12,022 m3/h, based on nominal schedule 40S or STD inner diameter. OIML R117 applications are limited to the ranges shown on the certificate.

Calibration practice deserves attention in any custody project. The manufacturer performs laboratory calibration to match the application, using either a single fluid or several fluids, and each LCT4 is calibrated to adhere to the OIML R117-1 standard. A terminal that ships both light products and fuel oil can therefore specify a multi-fluid calibration, while a dedicated line for a single grade may be served with a single-fluid certificate. Because the meter keeps its accuracy through viscosity swings, the operator does not need to hold a viscosity table in the flow computer or schedule a proving campaign every time the batch changes. Any local legal-metrology authority remains free to impose its own verification interval, so the purchase specification should state the approvals needed and the country of use.

Electrical integration is straightforward. Standard I/O includes two isolated frequency or pulse outputs, two alarm relays and a 4-20 mA output with HART, with Modbus RTU and PanaLink over serial or USB for supervisory access. Temperature, pressure and density can be wired into the meter either as two 4-20 mA inputs and a 100 ohm RTD or as three 4-20 mA inputs, so the integrated flow computer can perform API 11.1 corrections without a separate panel. The electronics can be remotely mounted using an adapter and cable if the spool sits in a location that is difficult to reach, while the diagnostic master screen in PanaView exposes signal quality for every path.

Using LCT4 in Oman terminals and pipelines

Custody transfer meters in Oman serve crude export lines, product loading, jetty lines and refinery allocation, as well as pipeline leak detection. A compact flowcell is useful where skid space is limited, and the integral cable design avoids junction boxes in hazardous areas. Magnetic-induction programming protects the hazardous-area integrity of the enclosure.

Installation and verification

Fit the flowcell with flanged ends, allow at least 10 diameters of upstream piping with a flow conditioner and 5 downstream, and bring in temperature, pressure and density signals if the built-in flow computer will perform API 11.1 corrections. PanaView provides real-time flow data, diagnostics history and a configuration audit trail.

Support and supplier statement

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; we advise on LCT4 sizing and flange class before ordering.

Documents and quotation

A manufacturer datasheet for Sentinel LCT4 is supplied. In your RFQ list LCT4, line size, flange class, body material, calibration fluid, approvals required and quantity.

Other Models in the Panametrics Sentinel Range

Seven Star LLC supplies models from the Panametrics Sentinel range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics Sentinel LCT Custody Transfer Ultrasonic FlowmeterUltrasonic FlowmetersView details
Panametrics Sentinel LCT8 Eight-Path Ultrasonic FlowmeterUltrasonic FlowmetersView details
Panametrics Sentinel LCT4 Compact Ultrasonic Liquid FlowmeterUltrasonic FlowmetersYou are viewing this model
Panametrics Sentinel LNG Cryogenic Ultrasonic FlowmeterUltrasonic FlowmetersView details
Datasheets & Documents
  • PDF Datasheet Panametrics Sentinel LCT4 Compact Ultrasonic Liquid Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics Sentinel LCT4 Compact Ultrasonic Liquid

Answers from our engineering team on installation, compatibility and integration.

01What accuracy does the Sentinel LCT4 state?
Linearity of plus or minus 0.15 percent of measured volume between 1 and 33 ft/s, with uncertainty under 0.027 percent per API MPMS 5.8.
02How does LCT4 differ from the original Sentinel LCT?
It is more compact with integral cables, covers 3 to 24 in, lists up to 660 cSt and 140 C, and needs 10D upstream with a flow conditioner.
03Which approvals does LCT4 carry?
OIML R117-1 Accuracy Class 0.3 with NMi certificate TC7595, plus further country-specific approvals on request.
04What pipe sizes does LCT4 offer?
3 in to 24 in with ANSI 150, 300 or 600 flange ratings and several pipe schedules.
05Must the LCT4 be recalibrated after replacing electronics?
No. The datasheet says replacing transducers or electronics needs no recalibration, which NMi tested as part of OIML certification.