Cortem SX7E 644 UL Class I Div 1 Junction Box
Description
Cortem SX7E 644: what the code means
Looking for Cortem SX7E 644? This is a compact UL certified Class I Division 1 aluminium explosion-proof junction box, 6 x 4 x 4 inch from the SX7E UL certified Class I Division 1 aluminium junction box series. Outside it measures 243 x 193 x 169 mm, inside 6 x 4 x 4 inch (154 x 105 x 102 mm), and it weighs 6.1 kg; the code digits mirror the internal size in inches. The marking printed in the data sheet is Class I Div. 1 and 2 Groups C-D; Class II Div. 1 and 2 Groups E-F-G; Class III; NEMA 3, 4X, 7 and 9, with UL file FTRV.E468486 (FTRV7.E468486 for Canada) listed as the certification basis.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and every figure here is paraphrased from the published data sheet, so please confirm it against the current edition when you order.
Key features
- UL listed for Class I Div. 1 and 2 groups C and D and Class II groups E, F, G
- NEMA 3, 4X, 7 and 9 enclosure types
- Aluminium alloy body with stainless steel bolts
- Body and cover drilled and threaded to customer specification
- Internal mounting plate in aluminium
Technical data for Cortem SX7E 644
| Part number | SX7E 644 |
|---|---|
| Series | SX7E UL certified aluminium junction boxes |
| External dimensions A x B x C | 243 x 193 x 169 mm |
| Internal size (inches) | 6″ x 4″ x 4″ |
| Internal size (mm) | 154 x 105 x 102 mm |
| Fixing D x E x F | 179 x 89 x 14 mm |
| Weight | 6.1 kg |
| Max NPT thread in body | 2″ |
| Classification | Class I Div. 1 and 2 Groups C-D; Class II Div. 1 and 2 Groups E-F-G; Class III |
| Certificate | FTRV.E468486; FTRV7.E468486 (Canada) |
| Enclosure types | NEMA 3, 4X, 7 and 9 |
| Standards | UL 886, UL 1203, NEC Art. 500-503 |
| Body and lid | Low copper aluminium alloy, polyester coating |
| Fasteners | Stainless steel bolts and screws |
| Mounting | Cast aluminium feet on the body; aluminium internal mounting plate |
How SX7E 644 differs from other SX7E variants
A quick comparison for SX7E 644 within the SX7E range follows; each point is taken from the selection chart of the data sheet.
- Internal depth 102 mm, against 150 mm for SX7E 666 and 200 mm for SX7E 888.
- Mass 6.1 kg, versus 9.0 kg for SX7E 666 and 13.0 kg for SX7E 888.
- NPT limit 2 inch, the same as the other three small codes but below the 4 inch of SX7E KK8.
- Fixing 179 x 89 x 14 mm.
Use cases across the Gulf
A Cortem SX7E 644 installation typically supports an Omani or Gulf plant that needs hazardous-area wiring points: upstream, midstream and downstream oil and gas, fuel depots, utilities, and industrial production halls. It is a small North American style junction box used on skids and packages built to NEC and UL rules and then shipped to Gulf plants. The family literature highlights refineries, chemical plants, onshore and offshore sites and fuel depots as typical settings.
Selection checklist
Compatibility checks for SX7E 644 are straightforward. Zone and group: see Class I Div. 1 and 2 Groups C-D; Class II Div. 1 and 2 Groups E-F-G; Class III; NEMA 3, 4X, 7 and 9. Temperature: not stated as a single range in the data sheet; follow the UL listing and the rating of the equipment fitted. Volume and wiring space: see the dimension rows above. The largest NPT in the body is 2 inch, which fixes the biggest gland or conduit hub you can request. Glands, stopping plugs and terminals added later should all carry their own Ex certification that suits the box.
Installing and servicing SX7E 644
During installation of SX7E 644, secure the box on a flat surface using the fixing points shown in the dimension data, connect the earth screws and tighten the cover fasteners fully so the joint and gasket do their job. Mount it on the 179 x 89 mm fixing with 14 mm slots; the cast feet are on the body, and drilling must be done by the manufacturer, as the sheet states. After wiring, check insulation resistance and continuity, record the work in the hazardous area inspection file and keep the certificate with the loop documents.
A sensible service routine for SX7E 644: inspect, clean, retighten, document. Because NPT entries are tapped by the manufacturer, inspect thread engagement and use sealing fittings as NEC requires; keep the cover bolts torqued. Keep spare cover screws and a gasket on file, never apply paint over the machined joint and record each opening of the cover in the plant inspection log.
Ordering information and FAQ summary
Companion parts for Cortem SX7E 644 include Ex certified glands, closing plugs, earth accessories and, where the data sheet allows, windows or breather and drain valves. State the accessories and entry layout in your RFQ so the quotation covers the complete assembly.
Why the exact code matters: SX7E 644 identifies one specific body, entry layout and size within the SX7E family, so a neighbouring code is not a drop-in replacement. For replacement purchases on older plants, compare the nameplate, the dimensions in the table above and the certificate reference before sending the order, and keep the marking Class I Div. 1 and 2 Groups C-D; Class II Div. 1 and 2 Groups E-F-G; Class III; NEMA 3, 4X, 7 and 9 on the purchase record.
To sum up, SX7E 644 is the smallest UL box in this selection; the FAQs cover internal size, certification, weight, NPT size and ordering.
Documents and quotation
Download the attached datasheet to confirm the figures summarised above. Then submit your RFQ with the exact part number SX7E 644, quantity and destination so we can reply with availability and delivery information.
Typical Questions From Maintenance Teams
Maintenance engineers replacing a Cortem SX7E 644 usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed switchgear, enclosures & distribution, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.
Other Models in the SX7E Range
Seven Star LLC supplies models from the SX7E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Cortem SX7E KK8 UL Class I Div 1 Panel Junction Box | Switchgear, Enclosures & Distribution | View details |
| Cortem SX7E 644 UL Class I Div 1 Junction Box | Switchgear, Enclosures & Distribution | You are viewing this model |
| Cortem SX7E 666 UL Class I Div 1 Cube Junction Box | Switchgear, Enclosures & Distribution | View details |
Datasheets & Documents
- Datasheet Cortem SX7E 644 UL Class I Div 1 Junction Box Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Cortem is the Italian maker of explosion-proof and increased-safety electrical equipment: Ex d and Ex e lighting, enclosures, control stations, plugs and sockets, cable glands and signalling devices. Marco Rossi and Renato Gratton founded the company on 24 February 1968 in Villesse, in the Friuli Venezia Giulia region of north-east Italy. Cortem S.p.A. heads the Cortem Group, which also includes Elfit and the Fondisonzo foundry, and supplies onshore and offshore oil and gas, chemical and industrial plants.
Seven Star LLC is an independent supplier in Muscat. We list Cortem junction boxes, lighting, plugs and sockets and control stations for oil and gas and process projects in Oman and the GCC.
Cortem company profile
| Founded | 24 February 1968, Villesse (Gorizia), Italy |
|---|---|
| Founders | Marco Rossi and Renato Gratton |
| Name | From the Italian for electromechanical construction and technical representation |
| Group companies | Cortem S.p.A., Elfit and Fondisonzo |
| Approvals | ATEX and IECEx certified explosion-protected equipment |
| Product families | Ex d and Ex e luminaires and LED fittings, emergency and exit lights, obstruction lights, junction and control boxes, control stations, plugs and sockets, cable glands, alarm and signalling devices |
Milestones
- 1968: Marco Rossi and Renato Gratton found Cortem in Villesse on 24 February.
- 2011: Research and development on LED lighting for hazardous areas begins.
- 2012: The first Cortem LED fixture series is launched.
- 2022: The third generation of Cortem LED fixtures is released.
Cortem product series
Enclosures include the EJBX stainless steel Ex d junction boxes, EJBC aluminium Ex d boxes for gas group IIC, the SA and SAG Ex eb aluminium boxes in 18 sizes and the EJBE and EJBXE Ex de control and distribution boards. Control and power connection products include the CMD Ex e fibreglass control stations and the PYN, SPYN and CMBSP07 Ex plugs and sockets from 16 to 125 A.
Lighting covers the SLED-ME and EVL-40 Ex LED floodlights, the Ex nR SLED-MN and EVNL-40 floodlights for zone 2, the LIFEX-M linear fixture, the FLOWEX high bay, the EVML low bay, STREETEX street lighting and the XLFE-LIB and XLFE-MIA obstruction lights for stacks and towers. The GRDE-4200 is an electronic earthing system for road tanker loading bays.
Where Cortem equipment is used
Refineries, gas plants, tank farms and loading terminals, offshore platforms and ships, chemical and pharmaceutical plants and mining. Products are certified to ATEX and IECEx, with other schemes according to model.
Cortem products we list
Ordering Cortem products: what we need
Send the model code, the zone and gas or dust group, temperature class, ingress protection, the certification scheme required, and for enclosures the size, entries and internal components. For lighting give the wattage, voltage and mounting; for plugs and sockets the current, poles and voltage.
Facts checked against Cortem Group's published company history, October 2026.
Browse Cortem products by category: Automation Accessories.
FAQ
Questions about the Cortem SX7E 644 UL Class I Div 1 Junction Box
Answers from our engineering team on installation, compatibility and integration.
01What is the internal size of Cortem SX7E 644?
6 x 4 x 4 inch, or 154 x 105 x 102 mm. This applies to part number SX7E 644 as listed in the manufacturer data sheet.
02What certifications does Cortem SX7E 644 carry?
UL file FTRV.E468486, with FTRV7.E468486 for Canada, covering Class I Div. 1 and 2 groups C-D and Class II groups E-F-G, plus Class III.
03How heavy is Cortem SX7E 644?
6.1 kg. This applies to part number SX7E 644 as listed in the manufacturer data sheet.
04What is the largest NPT hole for Cortem SX7E 644?
2 inch. This applies to part number SX7E 644 as listed in the manufacturer data sheet.
05How do I order Cortem SX7E 644?
Send an RFQ with SX7E 644, quantity and the drilling pattern needed.


















Reviews