- Automation & ControlView all 2,858 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Panametrics
Panametrics PanaFlow Z3 PF10-Z3 Three-Path Liquid Flowmeter
Description
PF10-Z3 PanaFlow Z3 three-path liquid flowmeter
The Panametrics PanaFlow Z3, ordered under the model code PF10-Z3, is the three-path member of the PanaFlow liquid range. A cast flowcell carries three pairs of LX transducers and a remote or local XMT1000 transmitter, and the manufacturer positions it as the choice when accuracy and reliability are critical, such as allocation, batching, blending, loading and unloading, and transfer lines. The PF10-Z3 is built at the factory ready to bolt between flanges, so there is no transducer alignment work in the field. Its datasheet lists oil and gas from upstream to downstream, chemical, petrochemical, refining, power generation, district energy and HVAC, water and wastewater, tank farms, irrigation and cooling water lines as intended duties.
What sets PF10-Z3 apart
- Three acoustic paths for sizes 3 in to 24 in (two paths on the 2 in flowcell sold as PF10-Z2).
- Accuracy of 0.25% of reading above 1.6 ft/s (0.5 m/s) on 3 to 24 in; 0.5% on 2 in.
- Repeatability of 0.15% of reading for 3 to 24 in, 0.2% for 2 in.
- Bidirectional range of minus 82 to plus 82 ft/s (minus 25 to plus 25 m/s).
- LX transducers with buffers that can be inserted and removed without isolating the meter or using special tools.
- Precision-machined cast body to keep flow disturbance small.
PF10-Z3 technical specifications
| Parameter | PF10-Z3 data |
|---|---|
| Meter body materials | Low-temperature carbon steel SA352 Gr. LCC; stainless SA351 Gr. CF8M; duplex SA995 CD3MWCuN |
| Transducer wetted parts | 316 SS or A479 UNS S32760 duplex, with FKM (petroleum) or EPDM (water) o-rings |
| Process temperature | -40 to 302 F (-40 to 150 C); 203 F (95 C) maximum if extra analog I/O is chosen on local mount |
| Flange options | ANSI 150, 300, 600 RF; EN 1092-1 PN10, 16, 25, 40, 63 |
| Design codes | ASME B31.3, NACE MR0103/MR0175, PED category II, CRN |
| Calibration | Water calibrated, 3 points as found (2, 5, 10 ft/s) and 2 as left (3, 7 ft/s), certificate supplied |
| Transmitter | XMT1000, powder-coated aluminum or SS316, 128 x 64 LCD, lockable magnetic keypad |
| Power | 100 to 240 VAC or 12 to 28 VDC; 15 W maximum, 7 W typical |
| Hazardous area | Class I Div 1 Groups B, C, D; Ex db IIB+H2 T6, ATEX and IECEx, IP66/67 |
| I/O | One 4-20 mA plus pulse or frequency output; optional SIL output, RTD and analog inputs |
| Communications | RS485 Modbus; optional HART 7 or Foundation Fieldbus FISCO |
| Cable entries | 3/4 in NPT or M20 adapters |
How PF10-Z3 compares with PanaFlow LZ
Both meters are wetted spool designs, yet the Z3 is stricter in performance. The LZ states 0.5% of reading from 2 to 40 ft/s with one or two paths; the Z3 states 0.25% above 1.6 ft/s using three paths and reaches 82 ft/s. The LZ body is a welded pipe spool with welded transducer ports in sizes up to 24 in, whereas the Z3 is an all-cast flowcell available in low-temperature carbon steel, CF8M stainless or duplex. The process temperature ceiling of 150 C in the Z3 is lower than the 175 C or 250 C possible with LZ transducer options, so hot services may favour the LZ.
Decoding the PF10-Z3 part number string
The string runs A to R plus Z. A is the model (PF10-Z3 or PF10-Z2), B the body size from 02 to 24, C the flange rating (1 to 3 for ANSI classes, E to J for PN classes), D the body material (CC, S6 or SD), E the schedule (such as 040, 080, 0XS, 10S, 40S, 80S, STD), F the system design standard (A, C for CRN, P for PED), G the paint (A none for stainless, G standard), H the NDE package (0, 1 with MPI/LPI and hydrotest, or 2 adding PMI on wetted parts), I the transducer o-ring (V Viton or E EPDM), and J the mounting, for example 000L local, 000R remote without cable or 0R25 remote with 25 ft cable per EN60079-14. Local mount is rated for up to 150 C on the process.
Applications in Oman and GCC facilities
With three paths the PF10-Z3 averages out swirl and profile distortion, which matters for custody-adjacent allocation on crude and product lines, tank farm transfers and loading gantries. Water utilities in Oman can use the EPDM version on large cooling or desalination feed lines, while power plants use it on closed-loop and district cooling circuits. The SIL option helps where the flow reading feeds a safety function.
Installing and commissioning the PF10-Z3
Fit the flanged body in line with a straight run of about 10 diameters upstream and 5 downstream, bolt the end flanges, and power the XMT1000. Weights and dimensions are given on drawings 712-2166 for local mount and 712-2167 for remote mount, covering 2 in to 24 in. Because the meter is water calibrated and delivered with its certificate, field work is mostly wiring and output scaling.
Selection tips for the PF10-Z3: choose EPDM o-rings for water, Viton for petroleum, and request the PMI option when the wetted material must be verified for a corrosion-sensitive process. For hazardous-area lines, the stainless transmitter enclosure with conformal coating suits coastal sites where salt-laden air is common along the Omani coast. Check that the process temperature stays below 95 C if two analog inputs or outputs are added to a locally mounted transmitter, otherwise move to remote mounting with the 25 ft cable option.
Maintenance and spares
No filters or strainers are needed. LX transducers can be withdrawn live, so replacement does not require a shutdown. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Documents and quotation
The manufacturer datasheet for PF10-Z3 is available on this page. For a quotation, send the PF10-Z3 string, body size, flange class, material, fluid and quantity as your RFQ.
Datasheets & Documents
- Datasheet Panametrics PanaFlow Z3 PF10-Z3 Three-Path Liquid Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics PanaFlow Z3 PF10-Z3 Three-Path Liquid
Answers from our engineering team on installation, compatibility and integration.
01How accurate is the PF10-Z3 PanaFlow Z3?
The datasheet gives plus or minus 0.25 percent of reading above 1.6 ft/s for 3 to 24 in sizes and 0.5 percent for the 2 in version.
02How many paths does the PF10-Z3 have?
Three paths from 3 in to 24 in; the 2 in size, ordered as PF10-Z2, uses two paths.
03Can PF10-Z3 transducers be replaced under pressure?
Yes. The LX transducer and buffer design allows safe insertion and removal at any time without isolating the meter or using special tools.
04What materials are available for the PF10-Z3 body?
Low-temperature carbon steel SA352 Gr. LCC, stainless steel SA351 Gr. CF8M and duplex SA995 CD3MWCuN.
05What maximum process temperature applies to PF10-Z3?
-40 to 302 F (-40 to 150 C), reduced to 203 F (95 C) on local mount when additional analog input or output options are selected.


















Reviews
There are no reviews yet.