Brand: Magnetrol
Magnetrol 089-7905-001 TG1 DIN Rail Housing and Electronics
Description
089-7905-001: DIN rail housing and electronics for Thermatel TG1
Magnetrol 089-7905-001 is the replacement DIN rail housing with electronics for the Thermatel TG1 thermal dispersion switch. In the manufacturer manual BE 54-605 it is item 5 of the spare part drawing, and the table says that the number follows the third digit of the electronics model code: digit 1 gives 089-7905-001, digit 2 gives 089-7905-002.
The TG1 is a split instrument. The sensor and its small housing sit in the process, and the amplifier is a plastic DIN rail module mounted in a panel up to 500 m away. When a unit has been damaged by a surge, a wiring fault or a wet panel, 089-7905-001 is the module that replaces the whole amplifier side in one step, so the loop can return to service without re-engineering the sensor. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What 089-7905-001 contains and what it does
- Standard LED flow indication: four green LEDs for the safe condition, one yellow LED when the flow or level approaches the set point, and one red LED for the alarm.
- A 2 A SPDT alarm relay plus a mA output that is non linear and not scaleable.
- A fault output of 3.6 mA for low level fail-safe or 22 mA for high level fail-safe.
- Set point adjusted with a potentiometer on the DIN rail housing; the range is selected in the probe electronics.
- Power and error LEDs for quick checking; the error LED blinks red if a fault is detected.
Technical data for 089-7905-001
| Parameter | Value |
|---|---|
| Part number | 089-7905-001 (third model digit 1) |
| Supply voltage | 19.2 to 28.8 V DC |
| Power consumption | 5 W maximum |
| Alarm output | 2 A SPDT relay |
| Continuous output | mA, non linear, non scaleable |
| Error output | 3.6 mA (low level fail-safe) or 22 mA (high level fail-safe) |
| Enclosure | DIN rail, IP 20, polycarbonate |
| Dimensions shown | 75 mm (2.95 inch) and 55 mm (2.16 inch) module sizes on the drawing |
| Ambient temperature | -40 to +70 C; storage -50 to +75 C |
| Humidity | 0 to 99 percent, non condensing |
| Response time | 1 to 10 s typical, depends on sensor type, application and set point |
| Repeatability | less than 1 percent at constant temperature |
| Safety integrity | SIL 1 as 1oo1 or SIL 2 as 1oo2 to IEC 61508; SFF 79.4 percent |
| Hazardous area | ATEX II 1 G EEx ia IIB T5 (ordering code A0); other approvals on request |
| Connecting cable | Two wire shielded instrument cable 0.50 mm2, 1 m to 500 m, ordered separately |
Where Magnetrol 089-7905-001 is used in oil and gas, utilities, water and manufacturing
A thermal dispersion switch is a low maintenance instrument, so the DIN rail amplifier is often forgotten until a panel fire, a water leak or a lightning surge takes it out. Typical Omani sites are skid panels for compressors, cooling water headers on power plants, desalination blower lines and gas headers in refineries, where the TG1 supervises minimum flow. The amplifier in a marshalling room is easier to reach than the sensor, which is why this module is the most frequent TG1 spare.
Because the module has a relay and a mA output, it can serve a trip, an alarm or a trend input on the same instrument. A SIL 1 or SIL 2 loop based on the FMEDA data in the manual keeps a record of the module revision, so replace it with the number found on the nameplate and keep the proof test history.
How 089-7905-001 differs from 089-7905-002 and from other TG1 spares
| Spare | Role |
|---|---|
| 089-7905-001 | DIN rail housing and electronics for model digit 3 = 1 (Thermatel TG1) |
| 089-7905-002 | Same table row, model digit 3 = 2 |
| 030-9114-001 | PC board in the sensor housing, not the DIN rail unit |
| 012-2101-345 | O-ring for the sensor housing cover |
| 004-9105-001 / 004-9142-001 | Cover for aluminium (digit 8 = 2 or T) / stainless (digit 8 = 6) housing |
So 089-7905-001 and 089-7905-002 are twins in the table, differing only in the model digit, and both belong to the DIN rail side. The sensor-side PC board is a different number, 030-9114-001, and the two must never be mixed up in a spares kit.
Selection and compatibility for 089-7905-001
- Read digit 3 of the electronics code on the nameplate: 1 selects 089-7905-001.
- The electronics code also holds the output (digit 4 = 1, relay with mA), supply (digit 5 = 2, 24 V DC) and mounting (D, remote DIN rail).
- The housing code T, 2 or 6 applies to the sensor housing, not to this module.
- Use only with a sensor and cable listed in the same manual; the ATEX certificate covers the DIN rail housing and the sensor separately.
Installation and commissioning of 089-7905-001
Snap the module on the DIN rail in a panel that keeps it within -40 to +70 C and non condensing humidity. Landing the supply on 19.2 to 28.8 V DC, connect the sensor through the shielded cable, then connect the relay and mA wiring. When the unit is in an intrinsically safe loop the manual calls for observing the special conditions of the ATEX certificate, including keeping the enclosure temperature below +70 C.
Adjust the set point with the potentiometer and watch the yellow and red LEDs while changing flow. The range selection is made in the probe electronics, so do it before trimming the potentiometer.
Maintenance of 089-7905-001
The module is not user serviceable. Keep a full spare on the shelf for critical services and record the proof-test result in the SIL file. Check the screws and the LED states during rounds; a blinking red error LED points to a sensor or cable fault, and the output then goes to 3.6 mA or 22 mA depending on the fail-safe selection.
Related products and ordering notes
Ask for the thread-on flanges (for example 004-5867-003 or 004-5867-029) and the housing spares together with 089-7905-001 if a complete TG1 spare kit is wanted. Send the nameplate model code of the electronics and the serial number with the request.
Documents and quotation
The manual BE 54-605 is supplied as a datasheet download so you can compare the electronics code table and the performance data above. To obtain a quotation, send an RFQ with part number 089-7905-001, quantity, the full model code of your TG1 and the delivery location.
Other Models in the Magnetrol Tg1 Spares Range
Seven Star LLC supplies models from the Magnetrol Tg1 Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol 089-7905-001 TG1 DIN Rail Housing and Electronics | Thermal Mass Flow Meters & Controllers | You are viewing this model |
| Magnetrol 030-9114-001 PC Board for Thermatel TG1 Sensor Housing | Thermal Mass Flow Meters & Controllers | View details |
Datasheets & Documents
- Datasheet Magnetrol 089-7905-001 TG1 DIN Rail Housing and Electronics Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol 089-7905-001 TG1 DIN Rail Housing and
Answers from our engineering team on installation, compatibility and integration.
01What is Magnetrol 089-7905-001?
It is the replacement DIN rail housing with electronics for the Thermatel TG1 thermal dispersion switch, item 5 in the spare parts drawing of manual BE 54-605.
02What does the 089-7905-001 module output?
It provides a 2 A SPDT alarm relay and a non linear, non scaleable mA output, with error outputs of 3.6 mA or 22 mA depending on the fail-safe setting.
03What supply does the module need?
The manual specifies 19.2 to 28.8 V DC and a maximum power consumption of 5 W.
04What is the difference from 089-7905-002?
The manual selects the number by digit 3 of the electronics model code: digit 1 gives 089-7905-001 and digit 2 gives 089-7905-002.
05Can Seven Star LLC supply 089-7905-001 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and your model code.