Michell S8000 S8K413 Precision Chilled Mirror Hygrometer

Description

Michell S8K413 overview: precision chilled-mirror dew-point hygrometer

The S8K413 is the order code of the S8000 Precision Chilled Mirror Hygrometer for -60 to +40 °C dew point with an internal pressure sensor, USB and Ethernet communications and 6 mm Swagelok fittings. It provides direct measurement of dew point, temperature and pressure with an accuracy of ±0.1 °C.

This page repeats the facts published by the manufacturer for S8K413 so that engineers, maintenance planners and buyers can confirm the code before sending an enquiry. The photograph shows the Michell product line that the S8K413 code belongs to, taken from the manufacturer product page.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list S8K413 so that procurement teams can quote the exact code that appears in the manufacturer documentation.

Key features of S8K413

  • ±0.1 °C dew-point accuracy and ±0.05 °C reproducibility
  • Frost Assurance Technology guarantees measurements below 0 °C are made over ice
  • RRS triple optics and Dynamic Contamination Correction
  • High-contrast touch-screen interface with trend graph
  • USB and Ethernet with Modbus RTU and Modbus TCP, SD card logging, two analog outputs
  • Low-pressure (1 barg) or high-pressure (20 barg) version

Michell S8K413 technical specifications

Parameter Value
Order code Michell S8K413 (configure with letters, e.g. S8K413-BAA)
Measurement range -60 to +40 °C dew point
Accuracy ±0.1 °C (±0.18 °F)
Reproducibility ±0.05 °C (±0.09 °F)
Operating pressure 0 to 1 barg or 0 to 20 barg version
Sample flow 500 to 1000 ml/min (750 recommended)
Process connections 6 mm Swagelok male
Power supply 85 to 264 V AC, 47/63 Hz, 120 VA
Dimensions 187 x 440 x 343 mm (h x w x d)
Weight 12.3 kg (27.11 lb)
Calibration options Standard traceable or UKAS / ISO 17025 5-point
Pump None, or internal pump for the 1 barg unit

Values above are taken from the manufacturer datasheet and order-code sheet listed on this page. The manufacturer states that specifications can change as part of continuous development, so confirm the current revision when the S8K413 is part of a tender or a certified installation.

Typical applications of S8K413 in Oman and the GCC

The manufacturer lists standards laboratory reference, transformer vacuum drying verification, clean and dry room monitoring, metallurgical process monitoring, calibration laboratory reference and compressed air dryer research. Calibration and quality laboratories in Oman use such references.

  • Oil and gas: gas processing plants, wellsites, export pipelines and metering stations
  • Utilities and power: turbine fuel gas, instrument air and compressed air systems
  • Water and desalination: process air, gas generation and laboratory support
  • Manufacturing and laboratories: calibration, electronics, pharmaceutical and industrial gas production

Dew point is the temperature at which water vapour in a gas begins to condense at a given pressure, so a lower dew point means drier gas. Pressure dew point is the value at line pressure and is the figure that matters for compressed air and process gas, while atmospheric dew point refers to the same gas expanded to ambient pressure and reads much lower. Moisture can also be expressed in ppmV, a pressure-corrected volume fraction, so always confirm the unit and the reference pressure on a specification.

Good sample handling decides the quality of any moisture or dew-point reading. Use stainless steel tubing, keep lines short, avoid dead legs and filter out particles and liquids before the sensor. Plastic or rubber tubing absorbs and releases water vapour and slows the response, particularly at low dew points, and ambient moisture can enter through poorly made fittings, so check for leaks after commissioning.

Selection and compatibility notes for S8K413

The order sheet has letters for pressure range (A 1 barg or B 20 barg), calibration (A standard or B UKAS) and sample pump (A none or B pump, 1 barg only). The S8000 Remote and S8000 RS are separate codes for other ranges.

Many Michell codes are built from a parent code followed by option letters. When you ask for a quotation for S8K413, copy the complete code from the instrument label or from your purchase specification, including every letter after the parent code, and state the serial number if the unit replaces an installed one.

Before ordering, collect the data that avoids mistakes: the complete code and option letters, the serial number and year of any installed unit, the supply voltage, the hazardous-area certificate required by the site, the process pressure and temperature, the gas composition and the connection type. For spares from older installations, a photograph of the nameplate helps confirm the match, and it is useful to say whether the item replaces a failed device or is for a new installation.

Ask for the calibration certificate type your quality system needs, such as a traceable factory certificate or an accredited laboratory certificate where the manufacturer offers it, and keep it with the asset record so the next calibration date is visible during audits.

Installation and commissioning of S8K413

Connect the sample through 6 mm fittings, keep flow around 750 ml/min and connect USB or Ethernet for logging.

Always read the current manufacturer manual before commissioning, check the hazardous-area certificate where one applies, verify the supply and signal wiring, and record the as-found settings so that the next service visit has a reference.

Gulf installations add heat, dust and humidity. Instruments mounted outdoors need shade or a suitable enclosure, cable glands that match the enclosure rating and sample lines that avoid condensation on cold desert nights. Compare the ambient temperature range in the table with the highest site temperature before choosing a mounting position.

Maintenance and calibration of S8K413

Clean the mirror periodically; services such as recalibration are listed as CM-TC and CM-DPUKAS.

Moisture and dew-point measurements drift only slowly when the sample is clean, so most problems seen on installations of this kind come from contaminated sample lines, leaking fittings, wrong flow or damaged cables rather than from the instrument itself. A planned calibration interval agreed with your quality system keeps the measurement traceable.

Related products and ordering notes for S8K413

The same manufacturer family includes sensors, transmitters, online hygrometers, chilled-mirror reference instruments, hydrocarbon dew-point analyzers, sampling systems and calibration equipment. Other Michell codes already listed on this site, such as the Easidew transmitters, the Promet EExd analyzer and the Condumax II, can be quoted together in a single RFQ.

S8K413 FAQ summary

Typical questions concern what the code means, which options apply and what to send with an enquiry. In short, it is a precision chilled-mirror dew-point hygrometer, and the figures in the table above come from the manufacturer documents. Questions that are not answered here can be sent with the RFQ.

Documents and quotation

The manufacturer datasheet for S8K413 is attached to this page where available. To request a quotation, send an RFQ with the part number S8K413, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.

Datasheets & Documents
  • PDF Datasheet Michell S8000 S8K413 Precision Chilled Mirror Hygrometer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the Michell S8000 S8K413 Precision Chilled Mirror

Answers from our engineering team on installation, compatibility and integration.

01What is S8K413?
S8K413 is a precision chilled-mirror dew-point hygrometer, as described in the manufacturer datasheet and order-code sheet.
02What range does S8K413 measure?
-60 to +40 °C dew point. See the manufacturer datasheet for details.
03Does S8K413 have an internal pressure sensor?
Yes, the order sheet describes the S8K413 with an internal pressure sensor fitted.
04Can Seven Star LLC supply S8K413 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for S8K413?
Send the part number S8K413, the quantity, the full option string or instrument serial number, any certificate needs and the delivery location so we can prepare an accurate quotation.