Brand:

Panametrics DigitalFlow GC868 Clamp-On Gas Ultrasonic Flowmeter

Description

Panametrics GC868 overview

The Panametrics DigitalFlow GC868 is a clamp-on gas ultrasonic flowmeter, a complete system for most gases including natural gas, compressed air, fuel gases, erosive, corrosive and toxic gases, high-purity gases and air separation gases. Historically, clamp-on ultrasonic metering was limited to liquids because the method did not work on metal pipes containing gas. Panametrics developed a technology that extends clamp-on metering to gas, and the GC868 is the second generation of it.

Because the transducers are clamped onto the outside of the pipe, nothing penetrates the pipe wall, there are no wetted or moving parts, no pressure drop and rarely any maintenance. This is especially useful for erosive, corrosive, toxic, high-purity or sterile gases. The manufacturer reports testing on metal tubes from 0.75 in (20 mm) to 24 in (600 mm), and states that demonstrated accuracy is better than plus or minus 2 percent of reading with plus or minus 0.5 percent repeatability. The system comprises the GC868 electronics, a pair of clamp-on gas transducers, a preamplifier and a clamping fixture.

Key features of the GC868

  • Clamp-on, unobstructed installation with no wetted parts.
  • No moving parts and no pressure drop.
  • Two-channel, two-path version available.
  • Sound speed output and supercompressibility compensation.
  • Transducer signals five to ten times more powerful than traditional ultrasonic transducers.
  • Wide choice of clamping fixtures: CFG-V1, CFG-V4, CFG-V8, CFG-V12 and CFG-PI by pipe size.
  • Two independent graphic displays with 39-key keypad.
  • Electronics can be located up to 500 ft (150 m) from the transducers.

Panametrics DigitalFlow GC868 technical specifications

Parameter Value
Fluid types Acoustically conductive gases meeting minimum density requirements
Pipe sizes Most gases: 0.75 to 24 in NB (20 to 600 mm DN) and larger
Pipe materials Most metals and plastics; no lined pipes
Accuracy (velocity) Pipes 6 in and smaller: 2 to 5 percent typical; above 6 in: 1 to 2 percent typical
Process calibration Plus or minus 0.5 percent of reading may be achievable
Repeatability Plus or minus 0.2 to 0.5 percent of reading
Measurement parameters Standard and actual volumetric flow and flow velocity
Power 100 to 130 VAC or 200 to 265 VAC, 50/60 Hz; optional 12 to 28 VDC; 20 W
Operating temperature -10 to 55 deg C (14 to 130 deg F)
Standard outputs Two isolated 0/4 to 20 mA, 550 ohm maximum
Optional I/O Six slots: analog outputs, analog or RTD inputs, totalizer/frequency outputs, alarm relays
Enclosure Epoxy-coated aluminum Type 4X/IP66 Class I Division 2 Groups A, B, C, D; options stainless, fiberglass, explosion-proof or flameproof
Size and weight 14.24 x 11.4 x 5.1 in (362 x 290 x 130 mm); 11 lb (5 kg)
Clamp-on transducer temperature -40 to 130 deg C standard; optional overall -40 to 230 deg C
Mounting couplant CPL-16

Clamp-on gas measurement depends on gas density and pipe wall thickness. The datasheet gives minimum pressure and maximum velocity tables by pipe size, wall thickness and transducer frequency (0.2, 0.5 or 1 MHz), and recommends consulting the manufacturer for natural gas with sulfur or high carbon dioxide content.

Typical applications in Oman and the GCC

Typical GC868 duties include natural gas, compressed air, hydrogen and air separation gases where cutting the pipe is undesirable. In Oman and the GCC it suits temporary or permanent verification metering on existing lines, compressed air audits in utilities, and metering of toxic or corrosive process gas where wetted sensors would be a risk.

Selection and compatibility notes

Check the installation requirement tables first. Pipe size, wall thickness and gas type decide the transducer frequency and the minimum gas pressure for a workable signal. Then choose the clamping fixture by pipe size, number of paths and I/O. Because thicker walls need higher gas density, low-pressure thick-wall installations may not be suitable.

Installation and commissioning

Clean the pipe surface, apply the couplant, align the transducers in the clamping fixture to the spacing calculated from pipe data, and mount the preamplifier. Observe a straight run of about 20 diameters upstream and 10 downstream. Set up pipe, wall and gas data in the instrument and check signal strength before accepting the reading.

Maintenance and service life

There are no wetted parts, so maintenance is limited to checking fixture tightness, couplant condition and diagnostic readings. Repeat the check after any pipe maintenance that disturbs the transducers.

Related products and ordering notes

Related items are the GM868 wetted gas flowmeter and XGM868i transmitter. For a GC868 RFQ please give gas, pressure, temperature, pipe diameter, wall thickness and material, plus I/O and area classification. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Quick answers about the GC868

  • What is the GC868? It is a clamp-on ultrasonic flowmeter for gases that mounts on the outside of the pipe with no wetted parts.
  • What pipe sizes does the GC868 cover? Most gases from 0.75 to 24 in nominal bore (20 to 600 mm DN) and larger, on metal and most plastic pipes but not lined pipes.
  • How accurate is the GC868? Typical velocity accuracy is 2 to 5 percent for pipes 6 in and smaller and 1 to 2 percent above 6 in, with repeatability of 0.2 to 0.5 percent.

Documents and quotation

A manufacturer datasheet for the GC868 is available from Seven Star LLC on request and is attached to this listing where provided. To receive a quotation, send the RFQ with the part number GC868, the quantity required and your delivery location, together with any hazardous area, range or configuration details from your project specification.

Selection Notes for the Panametrics DigitalFlow GC868

When comparing the Panametrics DigitalFlow GC868 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment it will sit in, and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any of these points are uncertain, send a photo of the nameplate and a short description of the application; our team will compare it with the flowmeters range and confirm the correct order code before you commit to a purchase.

Other Models in the Panametrics Digitalflow Range

Seven Star LLC supplies models from the Panametrics Digitalflow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Panametrics DigitalFlow XMT868i Liquid Ultrasonic Flow TransmitterUltrasonic FlowmetersView details
Panametrics DigitalFlow XGS868i Steam Ultrasonic Flow TransmitterUltrasonic FlowmetersView details
Panametrics DigitalFlow GC868 Clamp-On Gas Ultrasonic FlowmeterUltrasonic FlowmetersYou are viewing this model
Panametrics DigitalFlow DF868 Liquid Ultrasonic FlowmeterUltrasonic FlowmetersView details
Datasheets & Documents
  • PDF Datasheet Panametrics DigitalFlow GC868 Clamp-On Gas Ultrasonic Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics DigitalFlow GC868 Clamp-On Gas

Answers from our engineering team on installation, compatibility and integration.

01What is the GC868?
It is a clamp-on ultrasonic flowmeter for gases that mounts on the outside of the pipe with no wetted parts.
02What pipe sizes does the GC868 cover?
Most gases from 0.75 to 24 in nominal bore (20 to 600 mm DN) and larger, on metal and most plastic pipes but not lined pipes.
03How accurate is the GC868?
Typical velocity accuracy is 2 to 5 percent for pipes 6 in and smaller and 1 to 2 percent above 6 in, with repeatability of 0.2 to 0.5 percent.
04How far can the electronics be from the transducers?
The datasheet states the electronics console can be located up to 500 ft (150 m) from the transducers.
05What fixtures are used with the GC868?
The datasheet lists CFG-V1, CFG-V4, CFG-V8, CFG-V12 and CFG-PI clamping fixtures depending on pipe size.