Brand:

Siemens 3RH2131-1BB40 SIRIUS Contactor Relay 3 NO + 1 NC

Description

3RH2131-1BB40 SIRIUS 3RH2 contactor relay, 3 NO + 1 NC, 24 V DC

The Siemens 3RH2131-1BB40 is a SIRIUS 3RH2 contactor relay (auxiliary contactor) in the S00 frame with 3 NO + 1 NC contacts and a 24 V DC coil. Siemens describes it as: contactor relay, 3 NO + 1 NC, 24 V DC, 50/60 Hz, screw terminal, frame size S00. A contactor relay does not carry motor current; its job is to repeat and multiply control signals, so it sits in the control circuit between a PLC, a push button or a protection output and the larger power contactors it commands. Seven Star LLC supplies the Siemens 3RH2131-1BB40 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

Siemens 3RH2131-1BB40 technical specifications

Parameter Specification
Manufacturer / part number Siemens / 3RH2131-1BB40
Product family SIRIUS 3RH2 contactor relay
Frame size S00
Contact arrangement 3 NO + 1 NC
Coil voltage 24 V DC
Pick-up power of coil 4W
Holding power of coil 4W
Closing / opening delay 30 to 100 ms / 7 to 13 ms
Arcing time 10 to 15 ms
Contact current AC-15 at 230 V / 400 V / 690 V 10 A / 3 A / 1 A
Contact current DC-13 at 24 V / 110 V / 220 V (1 path) 10 A / 1 A / 0.3 A
Contact reliability 1 faulty switching per 100 million (17 V, 1 mA)
Mechanical service life (typical) 30,000,000 operating cycles
No-load switching frequency, AC 10,000 per hour
Insulation voltage (pollution degree 3) 690 V
Ambient temperature, operation / storage -25 to +60 °C / -55 to +80 °C
Dimensions (H x W x D) 57.5 mm x 45 mm x 73 mm
UL contact rating A600 / Q600

How the 3RH2131-1BB40 works as a control relay

Applying 24 V DC to the A1 and A2 terminals energises the magnet and moves all contacts together: the NO contacts close and the NC contacts open. With the Siemens 3RH2131-1BB40 the coil needs 4W for pick-up and 4W to hold, so a PLC relay output or a pilot contact needs to be sized for that apparent power, not just for a few watts. Closing takes 30 to 100 ms and opening takes 7 to 13 ms, which is fast enough for most interlock and sequencing circuits but not instantaneous, so allow for it in timing-critical logic.

Because the contacts are rated for AC-15 and DC-13 duty, they are meant for switching inductive loads such as the coils of other contactors, solenoid valves and signalling devices. The datasheet gives 10 A at 230 V AC-15 and 10 A at 24 V DC-13 per contact. At higher DC voltages the permissible current falls sharply (for example 0.3 A at 220 V DC), so check the DC rating before using these contacts for DC solenoids or brakes.

Where the 3RH2131-1BB40 fits in a SIRIUS control circuit

In a typical motor starter the contactor relay repeats a start command from a remote station, interlocks the forward and reverse contactors, or isolates a PLC output from a high-inrush coil. The S00 frame shares the 45 mm width with the 3RT2 contactors of the same size, such as 3RT2015-1AP01, 3RT2016-1AP01, 3RT2017-1AP01 and 3RT2018-1AP01, so relays and contactors line up on the rail. The front of the device accepts 3RH29 auxiliary blocks, among them the 3RH2911-1HA22 listed on this site, which extend the contact count when the built-in 3 NO + 1 NC is not enough.

Selecting the 3RH2131-1BB40: ordering checklist

  • Count the contacts the circuit needs: this relay has 3 NO and 1 NC; the family also includes variants with different make and break counts.
  • Check the loads the contacts will switch: 10 A at 230 V AC-15 and 10 A at 24 V DC-13.
  • Confirm the control power: 4W pick-up and 4W holding.
  • The datasheet states a contact reliability of 1 faulty switching per 100 million (17 V, 1 mA), which means the contacts can switch small signal levels such as PLC inputs, but a contact that has switched higher currents should not afterwards be used on 17 V and 1 mA. For maintenance, keep the coil supply within its operating range, check for coil hum or chatter, and replace the relay when contact resistance rises. As a spare, a single part number is easy to stock, and the 3RH2131-1BB40 is a common replacement during panel refurbishment.

    Typical applications of the 3RH2131-1BB40 in Oman and the GCC

    In Oman and the GCC, contactor relays like the 3RH2131-1BB40 appear in pump and fan control panels, motor control centres, burner and boiler management panels, water treatment skids and desalination plants. They repeat start and trip signals, form interlocks between redundant pumps and isolate PLC outputs. In coastal and desert plants the main concerns are heat inside the cabinet, dust and humidity, so the rated ambient range of -25 to +60 °C and good panel ventilation matter more than the contact count.

    3RH2 contactor relays we can supply, compared

    Part number Contacts Coil Weight Dimensions (H x W x D)
    3RH2122-1AP00 2 NO + 2 NC 230 V AC 219.8 g 57.5 mm x 45 mm x 73 mm
    3RH2131-1AP00 3 NO + 1 NC 230 V AC 0.219 kg 57.5 mm x 45 mm x 73 mm
    3RH2140-1AP00 4 NO 230 V AC 0.217 kg 57.5 mm x 45 mm x 73 mm
    3RH2122-1BB40 2 NO + 2 NC 24 V DC – 57.5 mm x 45 mm x 73 mm
    3RH2131-1BB40 (this product) 3 NO + 1 NC 24 V DC – 57.5 mm x 45 mm x 73 mm
    3RH2140-1BB40 4 NO 24 V DC – 57.5 mm x 45 mm x 73 mm

    Information to send with an RFQ for the 3RH2131-1BB40

    • The full part number 3RH2131-1BB40 as printed on the nameplate or in the bill of materials
    • Quantity and delivery location in Oman or the GCC
    • Required contact arrangement and coil voltage (24 V DC for this part number)
    • Loads to be switched by the contacts, with voltage and AC or DC

    Documents and quotation

    A copy of the Siemens datasheet for the 3RH2131-1BB40 is attached on this page, so you can check ratings, dimensions and connection data before ordering. Seven Star LLC quotes against the exact part number, because neighbouring variants differ in coil voltage, range or contact arrangement and are not interchangeable without checking.

    Send the part number 3RH2131-1BB40, the quantity and the delivery point in Oman or the GCC through the RFQ form, and we will reply with availability and lead time. Seven Star LLC is an independent supplier based in Muscat and is not affiliated with the manufacturer.

    Other Models in the Siemens Sirius 3rh2 Range

    Seven Star LLC supplies models from the Siemens Sirius 3rh2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

    ModelCategory
    Siemens 3RH2122-1AP00 SIRIUS Contactor Relay 2 NO + 2 NCContactors & Overload RelaysView details
    Siemens 3RH2131-1AP00 SIRIUS Contactor Relay 3 NO + 1 NCContactors & Overload RelaysView details
    Siemens 3RH2140-1AP00 SIRIUS Contactor Relay 4 NOContactors & Overload RelaysView details
    Siemens 3RH2911-1HA22 Front Auxiliary Switch Block 2NO+2NCContactors & Overload RelaysView details
    Siemens 3RH2122-1BB40 SIRIUS Contactor Relay 2 NO + 2 NCContactors & Overload RelaysView details
    Siemens 3RH2131-1BB40 SIRIUS Contactor Relay 3 NO + 1 NCContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Siemens 3RH2131-1BB40 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Siemens is the German technology group whose industrial products include SIMATIC controllers and HMIs, SINAMICS drives, SIRIUS and SENTRON switching and protection devices, SIPROTEC protection relays, SITRANS process instruments, SCALANCE networks and process analysers. It was founded in Berlin on 12 October 1847 by Werner von Siemens and the precision mechanic Johann Georg Halske as Telegraphen-Bauanstalt von Siemens & Halske, to build Siemens's newly designed pointer telegraph. Siemens AG is headquartered in Munich and listed on the Frankfurt Stock Exchange; its energy business was spun off as Siemens Energy in 2020.

Siemens company profile

Founded 12 October 1847, Berlin, Germany, as Telegraphen-Bauanstalt von Siemens & Halske, with 10 employees
Founders Werner von Siemens (1816–1892) and Johann Georg Halske (1814–1890)
First product The pointer telegraph designed by Werner von Siemens
Headquarters Munich, Germany (Siemens AG)
Ownership Public company listed in Frankfurt; Siemens Energy (2020) and Siemens Healthineers are separately listed companies
Businesses acquired that appear in our range Moore Products (bought in 2000; APACS and QUADLOG control systems), Applied Automation (Maxum process gas chromatographs); small industrial gas turbines such as the SGT-300 came with Alstom's industrial turbine business in 2003
Product families SIMATIC S7 PLCs, ET 200 distributed I/O and HMI panels, TIA Portal software, SINAMICS drives, SIMOTICS motors, SIRIUS and SENTRON low voltage devices, SIVACON switchboards, SIPROTEC relays, SITRANS instruments, SCALANCE network components, building technology valves and sensors

Milestones

  • 1847: Siemens & Halske starts work in Berlin with 10 employees.
  • 1848: The company wins the contract for Europe's first long-distance telegraph line, Berlin to Frankfurt am Main.
  • 1856: 330 employees, two-thirds of them working on telegraph networks in Russia.
  • 1866: Werner von Siemens describes the dynamo-electric principle, the basis of the electric generator.
  • 1958 onwards: The SIMATIC name is used for Siemens industrial automation; S7 PLCs follow in the 1990s and S7-1500 in 2012.
  • 2020: Siemens Energy is spun off and listed separately.

Choosing Siemens automation products

A Siemens order number (MLFB) identifies the exact product: 6ES7 is SIMATIC automation, 6AV is HMI, 6GK is industrial communication, 6SL is SINAMICS drives, 3R is SIRIUS control and 5SY is SENTRON miniature circuit breakers. For PLCs, S7-1200 is the compact controller for small machines, S7-1500 is the current mid-to-high range controller, and S7-300 and S7-400 are older platforms still running in many plants; S7-300 is being phased out, so spares and migration to S7-1500 are common requests. When replacing a CPU or module, the full order number including the version digits matters, because firmware and hardware versions affect compatibility with the existing project.

Where Siemens products are used

In Oman and the GCC, Siemens automation runs in oil and gas, power and desalination plants, water networks, cement and process industries. Maxum gas chromatographs analyse gas composition in gas plants and refineries, SIPROTEC relays protect substations, SGT-300 turbines drive generators and compressors, and Siemens building valves are used in HVAC systems.

Siemens products we list

Family Examples
SIMATIC controllers and I/O S7-1500, CPU 1515-2 PN, S7-1200, CPU 1214C, S7-300, S7-400H CPU 412-5H, ET 200SP, IM 153-2
HMI and networking KTP700 Basic, TP700 Comfort, TP1200 Comfort, SCALANCE XC208, SCALANCE WAM766, PROFIBUS OLM
Drives, motors and power distribution SINAMICS G120C, SINAMICS G120X, 1LA7 motor, SIVACON S8, SIPROTEC 7SJ85, 5SY4510-7 MCB
Process instruments SITRANS P320, MAG 5100W, SITRANS TH320, SITRANS TS500, SITRANS TR200
Maxum II analyser spares FID 302A detector, FPD II assembly, filament detector, Model 50 valve, SYSCON kit, air bath heater
APACS and QUADLOG spares QLCCM24AAN, QLSAMBAN, QLSDM024DCCBN, 39SAMCAN, 16137-151 M-BUS cable
Building technology VPI46 PICV, VPF44, QFM1660 sensor

Ordering Siemens products: what we need

Send the full order number from the label (for example 6ES7214-1AG40-0XB0) and, for PLC and HMI parts, the hardware and firmware version (FS and V numbers). For Maxum II and APACS spares, send the Siemens part number such as 2021651-002. For drives, add the motor power and supply voltage.

Frequently requested Siemens models: Siemens IM 155-6 PN ST ET 200SP Interface Module 6ES7155-6AU02-0BN0, Siemens SGT-300 Industrial Gas Turbine.

Facts checked against Siemens's published history timeline, October 2026.

FAQ

Questions about the Siemens 3RH2131-1BB40 SIRIUS Contactor Relay 3 NO +

Answers from our engineering team on installation, compatibility and integration.

01What contact arrangement does the 3RH2131-1BB40 have?
The 3RH2131-1BB40 has 3 normally open and 1 normally closed contacts, described as 3 NO + 1 NC on the Siemens datasheet. Extra contacts can be added with a snap-on 3RH29 auxiliary block.
02What coil voltage does the 3RH2131-1BB40 need?
It uses a 24 V DC coil, with a pick-up power of 4W and a holding power of 4W. Make sure the control supply or PLC output can deliver this apparent power.
03How fast does the 3RH2131-1BB40 switch?
The datasheet gives a closing delay of 30 to 100 ms and an opening delay of 7 to 13 ms. This is suitable for interlocks but should be allowed for in timing-critical sequences.
04Can the 3RH2131-1BB40 switch DC loads?
Its contacts are rated DC-13 at 10 A for 24 V and 0.3 A at 220 V for one current path. The rating drops with higher DC voltage, so check the table before switching DC coils.
05What size is the 3RH2131-1BB40?
It is an S00 frame relay measuring 57.5 mm x 45 mm x 73 mm . It snaps onto 35 mm DIN rail alongside S00 contactors.