The Caprari D-M Series is a family of electric, vertical, close-coupled submersible pumps for 50 Hz supply. The catalogue (code 996913/07-25) joins eight sub-ranges: the D pumps (DA, DM, DR, DX and DW) for clean or slightly dirty water without fibres, and the M pumps (MG, MS, MS.T and MX) with wider free passage for screened wastewater. Caprari describes the choice as running from light domestic pumps that are easy to carry to heavy-duty work-site pumps, and all pumps are stated to comply with the pertinent European Directives.

Operation is simple: connect the power cable to the electrical control and protection equipment and the delivery hose or pipe to the pump outlet. The D series can handle clean or slightly dirty, non-aggressive water with no fibres or filaments that might clog the strainer slots or the impeller. The M series has wider ball passages and carries screened wastewater with larger solids, the permissible size depending on the available ball passage. The MS.T series adds a treated stainless steel grinder that reduces coarse and fibrous solids into small fragments.

Technical specification by sub-series

Series Construction and impeller Solids or ball passage Liquid temperature Immersion depth Motor and cable
DM Stainless steel and polymers, open impeller, float switch Clean or slightly dirty water 35 C 5 m max Single-phase 230 V, thermal protector, H05RN-F cable 5 m with plug
DA Cast iron, open impeller, double mechanical seal with oil chamber Suspended solids to 10 mm 35 C 5 m max, 205 mm min Three-phase (DA.R) or single-phase 230 V (DA.R.M); cable 10 m
DR Cast iron, open impeller with wear plate, double frontal seal Water with abrasive materials 40 C 20 m max, 457 mm min Three-phase 400 V or single-phase 230 V; cable 10 m up to 4 kW, 20 m above 5 kW
DX and DW AISI 304 (DX) or AISI 316 (DW) stainless, open (R) or vortex (W) impeller 10 mm (12 mm on DX.R 12) for R; 25 mm for W 50 C (40 C for DX.R 12) 5 m max Three-phase 230/400 V or single-phase 230 V; motor cooled by pumped water
MG Cast iron, single-channel (M) or vortex (W) impeller 45 mm (MG.M) and 50 mm (MG.W) 35 C, pH 6 to 11 10 m max Three-phase 230/400 V with 2 thermal protectors, cable 10 m; or single-phase 230 V
MS Cast iron and stainless steel, vortex or two-passage impeller 40, 50 and 65 mm 35 C, pH 6 to 11 5 m max, 200 to 355 mm min by size Three-phase 230/400 V or single-phase 230 V; cable 10 m
MS.T Cast iron and stainless steel with grinder, DN32 PN6 or G 1 1/2 outlet 6 mm passage; long fibres, paper, textiles 35 C 5 m max, 300 mm min Three-phase or single-phase with control panel and starting capacitors
MX Stainless steel, two-passage (D) or vortex (W) impeller Solids to 35 mm 35 C 5 m max, 248 mm min Three-phase 230/400 V or single-phase 230 V with float switch and thermal protector; cable 10 m

Common to the sub-series: 2-pole induction motor at 50 Hz (about 2,900 rpm), insulation class F, IP68 for continuous immersion, and construction in accordance with EN 60034-1, EN 60335-1 and EN 60335-2-41 where the catalogue prints those standards (confirmed for DA, DM and MX).

Pump coding, options and materials

Model codes follow one logic. For example DACR032D10+000521M1/G reads DA series, C for 50 Hz, R for open impeller, 032 for delivery DN, D for flanged or threaded delivery, 10 for total head in metres indoors, 0005 for nominal power in kW (0.5 kW), 2 poles, supply voltage code 1, M for single-phase (T for three-phase), generational code 1, and /G for fitted with float. Nominal powers across the listed models run from about 0.3 kW to 11 kW, derived from the coded model lists.

On the DA, the catalogue lists cast iron pump casing and impeller, alumina/carbon/rubber mechanical seals on pump and motor side, a stainless steel shaft, filter and motor shroud, and a polypropylene or stainless handle, with stainless steel screws and nuts. Special executions on request include other voltages, another mechanical seal, a different cable length, a motor suitable for frequency converter operation and single-phase versions without a float.

Choosing a sub-series

For rainwater pits and flooded basements with clean water, the DM or DA are the light options; for construction sites and abrasive water the DR with its 20 m immersion rating and wear plate is the heavy duty choice. The stainless DX and AISI 316 DW models are the corrosion-resistant range; the catalogue lists clean or slightly dirty water as their liquid, so confirm any other medium with Caprari. For wastewater, use the free-flow vortex models when long fibres are present, the grinder MS.T when a small bore discharge pipe is required, and the MG, MS and MX models for larger solids.

The catalogue includes operating data, overall dimensions, weights and technical features for every model, so the final selection must use the page for the exact pump.

Selection and installation notes

Select a pump from the duty point: the flow, the head, the liquid and its temperature, the supply voltage and the expected operating hours. Check the electrical supply and cable size against the motor rating, install the pump as the manual shows, protect the motor against overload and dry running, and fit non-return and isolation valves in the delivery line. Keep the installation and commissioning record, and plan routine inspection of seals, bearings and wear parts.

For submersible drainage pumps, check the free passage against the solids in the liquid, use a stable base or guide rails, keep the float switch free to move and keep cables out of the liquid path.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Using the D-M in GCC projects

Typical jobs are construction dewatering, basement and underground car park sumps, stormwater pits after heavy rain, and screened sewage lifting in buildings and small stations. Liquid limits are only 35 to 50 C, so pumps are not for hot process liquids. Because hazardous-area, seawater and fire approvals are not given in this catalogue for the D-M series, none is claimed.

Related pumps can be browsed in the pumps category. The Caprari catalogue is attached. Seven Star LLC is an independent supplier in Muscat: send the sub-series, power, voltage, liquid and head and we will confirm the exact model against the Caprari catalogue before quoting.

Datasheets & Documents
  • PDF Datasheet Caprari D-M series 50 Hz submersible drainage and sewage pump catalogue (EN/FR/IT, 07-25) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Caprari is an Italian pump manufacturer founded in Modena in 1945, today part of the Wateralia group. It builds centrifugal pumps for water supply, irrigation, drainage, fire fighting and civil and industrial use.

Seven Star LLC is an independent supplier in Muscat. We list Caprari pumps for water utilities, farms, contractors and industry in Oman and the GCC.

Caprari product series

Borehole pumps include the E6NVX and E8NVX 6 and 8 inch stainless steel pumps and the Desert E4X and E6X sand-resistant pumps. Surface pumps include the NMC and NMCS monobloc EN 733 pumps from DN32 to DN150, the NC.E end-suction pumps for fire-fighting units, the PM high pressure horizontal multistage pumps, the CVD vertical multistage pumps and the SCC double-suction split case pumps from DN100 to DN700.

The P Series P6P and P8P are vertical lineshaft pumps, the MEC-MG, MEC-AG and BHG pumps are flanged for diesel engine drive, and the D-M Series covers submersible drainage and sewage pumps.

Where Caprari pumps are used

Well fields and water supply, farm irrigation, pressure boosting, fire-fighting pump sets, drainage of sites and basements, and sewage lifting.

Ordering Caprari pumps: what we need

Send the model or the required flow and head, the liquid, borehole diameter or installation type, power supply and motor or engine drive.

Frequently Asked Questions

What is the difference between D and M pumps?
D pumps handle clean or slightly dirty non-aggressive water without fibres; M pumps have wider ball passages for screened wastewater with larger solids.
What is the MS.T series?
A cast iron and stainless steel pump with a treated stainless steel grinder that reduces coarse and fibrous solids; solids passage 6 mm, outlet G 1 1/2 or DN32 PN6.
What is the protection class of the motors?
IP68 for continuous immersion, with insulation class F, as printed for the listed series.
What maximum liquid temperature applies?
35 C on most series, 40 C on DR, and 50 C on DX and DW (40 C for DX.R 12).
What is the maximum immersion depth?
5 m on most series, 10 m on MG and 20 m on DR.