Brand: Hanna Instruments
Hanna HI98192 Waterproof Portable EC, TDS and Salinity Meter
Description
Conductivity, TDS, resistivity and salinity from pure water to brine
The HI98192 is a waterproof portable conductivity meter that also reports total dissolved solids, resistivity and salinity. It covers 0.001 µS/cm up to 400 mS/cm of conductivity with auto-ranging, which lets one instrument handle ultrapure rinse water, process condensate, cooling-tower water and seawater-strength brine. Hanna states that the instrument complies with the USP standard, which makes it relevant to pure-water checks as well as general plant use.
Temperature is measured from -20.0 to 120.0 °C by a sensor inside the four-ring stainless steel HI763133 probe supplied with the kit, so the meter can apply temperature compensation continuously without a separate thermometer.
Technical specifications
| Parameter | Specification |
|---|---|
| Model / order code | HI98192 |
| EC range | 0 to 400 mS/cm, auto-ranging (display up to 1000 mS/cm absolute): 0.001 to 9.999 µS/cm, 10.00 to 99.99 µS/cm, 100.0 to 999.9 µS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm |
| EC resolution | 0.001 / 0.01 / 0.1 µS/cm; 0.001 / 0.01 / 0.1 mS/cm |
| EC accuracy at 25 °C | ±1 % of reading (±0.01 µS/cm or 1 digit, whichever is greater) |
| EC calibration | Automatic, up to five points with seven memorised standards (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) |
| TDS range | 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/L; 10.00 to 99.99 g/L; 100.0 to 400.0 g/L (auto-ranging); conversion factor 0.40 to 1.00 |
| Resistivity range | 1.0 Ω·cm up to 100.0 MΩ·cm, auto-ranging; accuracy ±1 % of reading |
| Salinity | % NaCl 0.0 to 400.0; seawater scale 0.00 to 80.00 ppt; practical salinity 0.01 to 42.00 PSU |
| Temperature | -20.0 to 120.0 °C, resolution 0.1 °C, accuracy ±0.2 °C excluding probe error |
| Temperature compensation | No TC, linear, or non-linear per ISO/DIS 7888 |
| Logging | 400 samples on demand; lot logging 5 s to 180 min, maximum 1000 samples |
| PC connection | Opto-isolated USB with optional HI92000 software |
| Power / protection | 4 x 1.5 V AA, about 100 hours without backlight; IP67 |
| Dimensions / weight | 185 x 93 x 35.2 mm / 400 g |
| Warranty (per Hanna) | 2 years |
Built for a wide conductivity span
Conductivity meters often force a choice between a low-range cell for pure water and a high-range cell for process liquids. The HI98192 combines both ends by auto-ranging across six decades and by accepting a five-point calibration from 0.00 µS/cm to 111.8 mS/cm. The user can fix a range manually, select a reference temperature of 15, 20 or 25 °C, set a temperature coefficient, and choose between three salinity scales according to the sample.
Diagnostic features alert the operator when the electrode needs cleaning, the meter recognises when the probe has been changed, and the manual describes a probe replatinization routine for the conductivity cell. Auto Hold captures the first stable reading, and the GLP feature recalls the last calibration for traceability.
Applications, points to check and what ships in the kit
Plant chemists use this class of meter for reverse-osmosis permeate, boiler feedwater, cooling water, condensate return, rinse water, hydrotest water and effluent. Brine and seawater work is covered by the salinity modes and the 400 mS/cm upper limit.
Confirm the expected conductivity range of each sample, the temperature compensation method your procedure requires, the probe cable length, and whether certified calibration standards must be bought with the meter. The 0.001 µS/cm lowest range is marked with an asterisk on Hanna’s own page, so for ultrapure-water validation confirm the working conditions with the manufacturer.
Per Hanna, the HI98192 is supplied with the HI763133 stainless steel four-ring conductivity probe, HI7031M 1413 µS/cm and HI7035M 111.8 mS/cm calibration solutions (230 mL each), two 100 mL beakers, HI92000 PC software, an HI920015 micro USB cable, four AA batteries, instruction manual, quick start guide, quality certificate and an HI720192 rugged carrying case. Related Hanna portable meters include the HI98190 for pH and ORP, the HI98193 for dissolved oxygen and the HI98199 for pH, EC and DO.
How the Hanna HI98192 works
The probe passes a small current through the sample and the meter measures how well the water carries it. It uses the sensor in the probe to correct the reading for temperature. TDS, resistivity and salinity are then calculated from the conductivity value.
Where the HI98192 is used
- Ultrapure rinse water
- Process condensate
- Cooling-tower water
- Seawater-strength brine
- General plant and field checks
Selection checklist for the HI98192
- Conductivity span
- TDS conversion factor
- Salinity scale
- Temperature compensation mode
- Probe type
- Logging need
- PC connection
- Battery runtime
Installation, commissioning and maintenance notes for the HI98192
Insert four AA batteries and connect the probe. Calibrate with fresh standards before use and rinse the probe between samples. Keep the probe clean and recalibrate at regular intervals.
Requesting a quotation for the Hanna HI98192
Please send the sample type, the conductivity range and any accessories needed. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
HI98192 meter type
It is a waterproof portable conductivity meter.
HI98192 maker
It is made by Hanna Instruments.
HI98192 reported values
It reports conductivity, TDS, resistivity and salinity.
HI98192 conductivity span
It covers 0.001 uS/cm up to 400 mS/cm.
HI98192 auto-ranging
The range changes automatically with the sample.
HI98192 resolution
Resolution steps are 0.001, 0.01 and 0.1 in each unit.
HI98192 calibration
Calibration is automatic at up to five points.
HI98192 memorised standards
Seven standards are memorised, from 0.00 uS/cm to 111.8 mS/cm.
HI98192 TDS range
TDS runs from 0.00 ppm to 400.0 g/L.
HI98192 TDS factor
The conversion factor can be set from 0.40 to 1.00.
HI98192 resistivity
Resistivity runs from 1.0 ohm cm to 100.0 Mohm cm.
HI98192 salinity scales
Scales are percent NaCl, seawater in ppt and practical salinity in PSU.
HI98192 temperature range
It measures from minus 20.0 to 120.0 degrees C.
HI98192 temperature resolution
Temperature resolution is 0.1 degrees C.
HI98192 probe
The kit includes the four-ring stainless steel HI763133 probe.
HI98192 probe sensor
The temperature sensor sits inside the probe.
HI98192 compensation modes
Modes are none, linear or non-linear.
HI98192 on-demand logging
It logs 400 samples on demand.
HI98192 lot logging
Lot logging runs from 5 seconds to 180 minutes, up to 1000 samples.
HI98192 PC connection
An opto-isolated USB port works with optional HI92000 software.
HI98192 power
It runs on four 1.5 V AA batteries for about 100 hours without backlight.
HI98192 size
The size is 185 x 93 x 35.2 mm.
HI98192 weight
The weight is 400 g.
Meter records for the HI98192
Record the standards used, the calibration date and the sample readings.
Choosing the right HI98192 setting
Choose the TDS factor and the compensation mode to suit the sample.
Documents and quotation
The instruction manual is attached to this listing. Find further instruments in Portable Test and Measurement or see the YSI ProDSS multiparameter meter for a different probe-based approach. Use the RFQ form with the model code and quantity to request availability and delivery details.
Datasheets & Documents
- Instruction Manual Hanna HI98192 Instruction Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hanna Instruments is a manufacturer of analytical instruments for pH, ORP, conductivity, dissolved oxygen, turbidity, chlorine and titration, founded in 1978 by Oscar and Anna Nardo. Its portable meters, benchtop meters, photometers and electrodes are designed to give laboratory-style results in plant and field conditions.
Water quality instruments
Waterproof portable meters such as the HI98190, HI98192, HI98193 and HI9829 cover pH, EC, dissolved oxygen and multiparameter logging, while photometers and turbidimeters address chlorine and turbidity checks in drinking water, wastewater, boilers, cooling circuits and process lines. Features such as CAL Check validation cuvettes, GLP calibration recall and on-board data logging are described in each Hanna manual.
Sourcing through Seven Star LLC
Seven Star LLC, an independent supplier in Muscat, lists Hanna Instruments meters with their manufacturer documents so that buyers in Oman and the GCC can compare ranges, calibration standards and kit contents before requesting a quotation.
Related products
Frequently Asked Questions
Hanna lists 0.001 µS/cm to 400 mS/cm with auto-ranging, and the display can show values up to 1000 mS/cm.
TDS, resistivity and salinity (as % NaCl, seawater scale in ppt, or practical salinity in PSU).
Automatically at up to five points using seven memorised standards from 0.00 µS/cm to 111.8 mS/cm.
No TC, linear, or non-linear compensation per ISO/DIS 7888, with a 15, 20 or 25 °C reference selectable.
The HI763133 four-ring stainless steel conductivity probe with internal temperature sensor.