Moxa NPort 5410 4-Port RS-232 Serial Device Server

Description

Four independent RS-232 ports with an LCD for on-site setup

The Moxa NPort 5410 connects up to four RS-232 serial devices to an Ethernet network. Every port works independently, so port 1 can run Real COM for a SCADA driver, port 2 can act as a TCP server and ports 3 and 4 as TCP clients. A built-in LCD panel and four buttons show the server name, serial number and IP address and allow the IP address, netmask and gateway to be entered without a PC (standard-temperature models only). Dual DC power inputs, a terminal block and a power jack, allow two supplies, and a built-in buzzer and real-time clock provide alerts. The series also includes RS-422/485 and isolated variants, described below.

Technical specifications

Parameter Specification
Ethernet 1 x 10/100BaseT(X) RJ45, 1.5 kV built-in magnetic isolation
Serial (NPort 5410) 4 x RS-232, DB9 male; signals TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Baud rate / format 50 bps to 921.6 kbps; data bits 5-8; stop bits 1, 1.5, 2; parity none, even, odd, space, mark
Operation modes Real COM, TCP Server, TCP Client, UDP, Ethernet Modem, Pair Connection, Reverse Telnet, Disabled
Management Telnet console, web console (HTTP/HTTPS), SNMPv1/v2c, SNMPv3, DHCP, DNS, SMTP, SNTP, LLDP
Security Local authentication, HTTPS (TLS 1.2), SNMPv3, AES-128, RSA-1024, SHA-256
Power 12 to 48 VDC (24 VDC for DNV), 2 inputs (terminal block and power jack); 365 mA at 12 VDC; watchdog timer
Housing Metal; 181 x 103 x 33 mm with ears, 158 x 103 x 33 mm without; 740 g
Installation Desktop, wall mount or DIN rail with optional kit
Operating temperature Standard models 0 to 55 deg C; wide-temperature models -40 to 75 deg C
Approvals as printed UL 62368-1; DNV; EN 55032/35; FCC Part 15B Class A; medical EN 60601-1-2 Class B and EN 55011 (NPort 5410/5450/5450I only)
MTBF / manufacturer warranty NPort 5410: 880,274 hrs / 5 years

NPort 5400 series models

Model Serial standard Connector Isolation Input current
NPort 5410 RS-232 DB9 male No 365 mA at 12 VDC
NPort 5430 RS-422/485 Terminal block No 320 mA at 12 VDC
NPort 5430I RS-422/485 Terminal block 2 kV 430 mA at 12 VDC
NPort 5450 / 5450-T RS-232/422/485 DB9 male No 365 mA at 12 VDC
NPort 5450I / 5450I-T RS-232/422/485 DB9 male 2 kV 550 mA at 12 VDC

Choosing and installing

Choose the 5410 when all four devices are RS-232. For RS-485 multidrop lines use the 5430 or 5450; isolated models help where devices sit at different earth potentials. The DIP switches on the bottom panel set termination and pull-up or pull-down resistors for RS-485, so no external resistors are needed. The LCD is not fitted on -T models, so set IP parameters through the web or Telnet console. Compare the two-port NPort 5210A if fewer connections are needed. Seven Star LLC, an independent supplier in Muscat, quotes the exact model; confirm serial standard, isolation and temperature before ordering. The Moxa datasheet (version 2.1) is attached, and related products are in Industrial Communications. The 740 g metal case has mounting ears for wall mounting, and a DIN-rail kit is available as an option. Medical-grade EMC ratings are printed for the 5410, 5450 and 5450I only, so check the model if that matters. Four ports in one box reduce IP addresses and switch ports compared with four single-port servers, but they also concentrate failure risk, so for critical loops consider splitting devices across two units. Moxa lists marine approval by DNV, with a 24 VDC supply for DNV installations, and medical EMC compliance (EN 60601-1-2 Class B, EN 55011) for the 5410, 5450 and 5450I. Immunity levels printed include 6 kV contact ESD and 2 kV power EFT. MTBF figures range from 678,381 hours for the NPort 5450I to 1,213,993 hours for the NPort 5450-T.

How the Moxa NPort 5410 works

The device sits between serial equipment and the Ethernet network. Data from a serial port is packed into network packets and sent to the host. Data from the host is unpacked and sent out of the serial port. Each of the four ports has its own mode, so one port can serve a SCADA driver while another talks to a remote host. The host sees the port as a normal COM port when Real COM mode is used.

Where the NPort 5410 is used

  • Connecting serial instruments to SCADA
  • Remote access to RS-232 devices
  • Retrofitting older equipment to Ethernet
  • Control rooms with several serial devices
  • Machine builders and system integrators

Selection checklist for the NPort 5410

  • Number of serial ports needed
  • Serial standard: RS-232, RS-422 or RS-485
  • Connector type
  • Isolation need
  • Standard or wide temperature model
  • Power supply and the dual inputs
  • Operation modes for the host software
  • Mounting: desktop, wall or DIN rail

Installation, commissioning and maintenance notes for the NPort 5410

Set the IP address from the LCD and buttons or from the web console. Connect each serial device with the right cable for its pins. Choose the operation mode for each port and set the baud rate and format to match the device. Test the link from the host. Change the default login and keep the firmware current.

Requesting a quotation for the Moxa NPort 5410

Please send the model, the power supply needs and the quantity. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

NPort 5410 serial ports

The unit has 4 RS-232 ports on DB9 male connectors, with signals TxD, RxD, RTS, CTS, DTR, DSR, DCD and GND.

NPort 5410 baud rate

The baud rate runs from 50 bps to 921.6 kbps, with 5 to 8 data bits and several parity settings.

NPort 5410 operation modes

The modes are Real COM, TCP Server, TCP Client, UDP, Ethernet Modem, Pair Connection, Reverse Telnet and Disabled.

NPort 5410 management

The device is managed by Telnet console, web console, SNMP, DHCP, DNS, SMTP, SNTP and LLDP.

NPort 5410 security

It offers local authentication, HTTPS with TLS 1.2 and SNMPv3.

NPort 5410 power

The supply is 12 to 48 VDC through two inputs, a terminal block and a power jack. The current is 365 mA at 12 VDC.

NPort 5410 housing

The metal housing measures 181 by 103 by 33 mm with ears, and the weight is 740 g.

NPort 5410 temperature range

Standard models work from 0 to 55 degrees C. Wide temperature models work from minus 40 to plus 75 degrees C.

Device records for the NPort 5410

Record the serial number, the IP address and the mode set for each port.

Choosing the right NPort 5410 model

Choose the 5410 for four RS-232 devices. Choose a 5430 or 5450 model when RS-422 or RS-485 is needed.

Datasheets & Documents
  • PDF Datasheet Moxa NPort 5400 series datasheet v2.1 Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Since 1987 Moxa, based in New Taipei City, Taiwan, has built networking hardware for places where an office switch would fail: substations, wellhead panels, roadside cabinets. Seven Star LLC lists Moxa industrial Ethernet switches and fiber converters and supplies Moxa networking devices to system integrators and plant teams in Oman as an independent supplier. Each request is checked against the full Moxa model name before we quote.

Moxa switches and converters listed here

The EDS-G508E is a managed switch with eight Gigabit ports from the EDS managed line. The EDS-316-MM-SC-T is a 16-port unmanaged switch with 14 copper ports, two multi-mode SC fiber ports and the wide-temperature option (-40 to 75 C). The TCF-142-S-SC-T belongs to the TCF-142 series, which converts RS-232/422/485 serial signals to single-mode fiber. Moxa also makes serial device servers, protocol gateways, wireless devices and industrial computers, used on SCADA and telemetry networks across the GCC.

Ordering Moxa devices: what we need

The suffixes carry the specification. Send the complete model name, including fiber mode and connector (MM-SC, SS-SC, ST), the -T wide-temperature suffix and any coating or approval suffix. Add the power supply voltage, the SFP modules needed and the quantity.

Frequently Asked Questions

How many ports does the NPort 5410 have?
Four RS-232 ports with DB9 male connectors.
Can each port run a different mode?
Yes, each serial port operates independently, for example Real COM, TCP Server or TCP Client.
How do I set the IP address on site?
With the built-in LCD panel and buttons on standard-temperature models.
Which models are isolated?
NPort 5430I, 5450I and 5450I-T have 2 kV isolation.
What power inputs are provided?
A terminal block and a power jack, 12 to 48 VDC, so two supplies can be connected.