61721 is the Vortice NORDIK INTERNATIONAL PLUS 140/56, a three-blade ceiling fan with 1,400 mm (56 inch) blade diameter. A single-phase capacitor motor turns it at 231 rpm for a maximum 13,500 m3/h, using only 70 W, which gives a service value of 3.214 (m3/min)/W.

A 56 inch ceiling fan for large rooms where air movement replaces cooling load

Ceiling fans move large volumes of air slowly. In the NORDIK INTERNATIONAL PLUS line the 140/56 model has three powder-coated steel blades of 1,400 mm diameter on a 375 mm steel rod, a white ABS motor cover and a start-capacitor motor with external rotor on ball bearings. The data sheet quotes a maximum airflow velocity of 1.69 m/s and sound power of 52.6 dB(A).

The fan is factory-prepared to accept an optional light kit for a lamp up to 150 W with an E27 screw fitting, and speed is selected through optional control units. The accessory bag contains the nuts, bolts, ceiling hook and rubber anti-vibration washer needed for assembly. Vortice states these appliances are designed for residential and commercial properties.

Key features as printed in the datasheet

  • 1,400 mm (56 inch) three-blade steel rotor, white polyester powder coat.
  • Single-phase capacitor motor, external rotor, ball bearings; 231 rpm.
  • 13,500 m3/h at 70 W; service value 3.214 (m3/min)/W.
  • 375 mm ceiling rod; accessory bag with hook and anti-vibration washer.
  • Optional light kit (E27, up to 150 W) and optional speed control units.
  • Certifications shown: CE, EAC, CB test certificate.

Technical specification

Technical data, as printed on the Vortice data sheet

Parameter Specification
Code / model 61721 / NORDIK INTERNATIONAL PLUS 140/56
Blade diameter 1,400 mm (56 inch)
Voltage / frequency 220-240 V, 50 Hz
Max absorbed current / power 0.33 A / 70 W
Insulation class I (earthing required)
Speed 231 rpm
Weight 7.00 kg
Max airflow 13,500 m3/h (225 m3/min)
Max air velocity 1.69 m/s
Service value 3.214 (m3/min)/W
Sound power 52.6 dB(A)

NORDIK INTERNATIONAL PLUS range (Vortice data sheets)

Code Model Max airflow m3/h Max pressure Pa Max power W Voltage V
61701 NORDIK INTERNATIONAL PLUS 90/36 8550 – 70 220-240
61711 NORDIK INTERNATIONAL PLUS 120/48 9900 – 70 220-240
61721 NORDIK INTERNATIONAL PLUS 140/56 13500 – 70 220-240
61731 NORDIK INTERNATIONAL PLUS 160/60 14000 – 70 220-240
61742 NORDIK INTERNATIONAL PLUS-R 140/56″IPX5 13500 – 70 220-240

Selection and ordering guide

Four sizes are listed: 90/36 (8,550 m3/h), 120/48 (9,900 m3/h), 140/56 (13,500 m3/h) and 160/60 (14,000 m3/h), all at 70 W absorbed power. The 140/56 reaches nearly the same airflow as the 160/60 with a smaller sweep, which helps in rooms with limited headroom. The PLUS-R 140/56 IPX5 version (61742) is the IPX5-rated variant.

As a rule of thumb, a larger diameter at low speed moves air more comfortably than a small fan at high speed; choose by room size, not by price alone.

Installation and operation notes

The booklet requires the bottom edge of the blades to be at least 2.3 m above the floor in residential premises and at least 2.7 m in non-residential premises. The ambient temperature must not exceed 40 C (104 F), the ceiling must be structurally able to carry the product and anchors must be tightened and unable to unscrew through rotation.

The unit must be connected to an efficient earthing system, kept at a suitable distance from walls and objects, and switched off when not in use. Mount it with the supplied hook and rubber washer, never with improvised fittings.

Applications in Oman and the GCC

Warehouses, showrooms, mosques and prayer halls, majlis rooms, workshops and cafes where destratification and a steady breeze reduce the load on air conditioning. Where splashing water is expected, ask for the IPX5-rated R version.

The unit is rated to an ambient of 40 C, which matters in uncooled Gulf spaces; avoid mounting it in direct heat sources.

Compatible accessories and related items

Related items: optional Vortice speed control units and light kit as described in the data sheet; siblings 61701 (90/36), 61711 (120/48), 61731 (160/60) and 61742 (PLUS-R 140/56 IPX5).

Sizing and maintenance notes

The number of ceiling fans in a room depends on its size and use. A 1,400 mm fan typically covers a medium-sized room, while large halls, mosques, classrooms and waiting areas often use several fans in a regular grid. Keep the blades at a safe height above the floor, as given in the instructions, and allow enough distance from the ceiling for air to be drawn in freely.

In the region, ceiling fans are often used together with air conditioning, as the air movement makes people feel cooler and can allow a higher thermostat setting. Mount the fan on a secure ceiling fixing able to carry the weight and the dynamic load. Clean the blades regularly, since dust on the blades adds weight unevenly and can cause wobble.

Information to send with an enquiry

  • Room size and ceiling height
  • Number of fans and any speed regulators needed
  • Rod length if the ceiling is high
  • Delivery location

Frequently asked questions

How much air does the NORDIK INTERNATIONAL PLUS 140/56 move?

Up to 13,500 m3/h (225 m3/min) at 231 rpm.

What power does it use?

0.33 A and 70 W maximum at 220-240 V, 50 Hz.

What mounting height is required?

Blade bottom edge at least 2.3 m above the floor in residential and 2.7 m in non-residential premises, per the booklet.

Can a light be added?

It is factory-prepared for an optional light kit with an E27 lamp up to 150 W.

Is Seven Star LLC a Vortice distributor?

No. Seven Star LLC is not a Vortice distributor; it is an independent Muscat-based supplier that quotes Vortice products on request.

Documents and quotation

This page carries the official Vortice technical data sheet for 61721. Seven Star LLC is an independent supplier in Muscat and sources Vortice products on request; tell us the quantity and delivery point to receive a quotation. Always confirm the order code and technical values in the document first. See more in the product category.

Datasheets & Documents
  • PDF Datasheet Vortice NORDIK INTERNATIONAL PLUS 140/56 61721 technical data sheet (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Vortice is an Italian manufacturer of fans and air treatment products, founded in 1954 by Attilio Pagani and headquartered in Tribiano, near Milan. Pagani began in his father's metalworking basement in Milan, where he created a cooker-hood extractor fan in thermosetting resin that gave the company its name and won a Compasso d'Oro design award. Vortice makes residential, commercial and industrial ventilation fans.

Vortice company profile

Founded 1954, Milan, by Attilio Pagani
Headquarters Tribiano, Milan, Italy
Design awards Compasso d'Oro
Product families Industrial axial plate fans, medium-pressure axial fans, centrifugal roof fans, in-line centrifugal and mixed flow fans, cabinet extractor fans, heat recovery units, residential extractor fans

Industrial fans, duct fans and air curtains

For commercial and industrial sites the Vortice range includes LINEO mixed flow in-line fans, CA roof and in-line centrifugal fans, QBK cabinet fans, A-E, E, MP and MPC-E axial fans, NORDIK ceiling fans and AIR DOOR air curtains, ordered by numeric code.

Supply through Seven Star LLC

Seven Star LLC is an independent supplier in Muscat that quotes Vortice products for projects in Oman and the GCC, with the Vortice technical data sheet attached to each product page.

Vortice products we list

Family Examples
Industrial Fans & Blowers A-E 636 T Industrial Axial Plate Fan 630…, CA 200 MD E RF Centrifugal Roof Fan 3-Sp…, CA IL 125 Compact Flat In-Line Centrifug…, LINEO 200 ES Energy Saving Mixed Flow In…, MP 454 T Medium-Pressure Axial Plate Fan…, VORT QBK HE SAL 315 4M Cabinet Extractor…

Facts checked against Vortice's own history page (vortice.com), October 2026.

Frequently Asked Questions

How much air does the NORDIK INTERNATIONAL PLUS 140/56 move?
Up to 13,500 m3/h (225 m3/min) at 231 rpm.
What power does it use?
0.33 A and 70 W maximum at 220-240 V, 50 Hz.
What mounting height is required?
Blade bottom edge at least 2.3 m above the floor in residential and 2.7 m in non-residential premises, per the booklet.
Can a light be added?
It is factory-prepared for an optional light kit with an E27 lamp up to 150 W.
Is Seven Star LLC a Vortice distributor?
No. Seven Star LLC is not a Vortice distributor; it is an independent Muscat-based supplier that quotes Vortice products on request.