Brand:

Servomex 2377-3646 Sample Block Filter for Servomex 700B

Description

Servomex 2377-3646 overview: sample block filter for the 700B zirconia analyser

The Servomex 2377-3646 is the sample block filter of the Servomex 700B. The manual parts list describes it as a filter of 15 to 25 micron rating, and the recommended spares list shows it as Filter Sample Block. It protects the heated sample block and downstream sensors from particulates in the aspirated sample.

The image on this page shows the exploded sensor head drawing from the manual of the Servomex 700B zirconia oxygen analyser (700 series flue gas analyser) that this item belongs to, so that buyers can recognise the equipment family; it is not a close-up of the sample block filter itself. Every detail on this page is taken from the manufacturer documentation for that equipment, and where a value is not stated there, we have left it out rather than guess.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Servomex 2377-3646 so that maintenance and procurement teams can quote the exact number that appears in the manufacturer manual, which matters because instrument spares are rarely interchangeable by description alone.

Key features of 2377-3646

  • Exact manufacturer part number 2377-3646, taken from the documented spares or parts list of the analyser.
  • Item: sample block filter.
  • Intended equipment: Servomex 700B zirconia oxygen analyser (700 series flue gas analyser).
  • The manual recommends 1 for one to three analysers, 2 for four to nine and 4 for ten or more, and lists the related gaskets as separate parts: 3931-7090 for the lower end, 3931-6718 for the fibre top end and 3931-7083 for the PTFE top end.
  • Supplied against a quotation request that confirms the analyser model, serial number and quantity.

Technical specifications for 2377-3646

The first table records the data for the part itself, as given in the manufacturer documentation. The second table records the main data of the host equipment, which helps confirm that the part suits the installation. No pricing is shown on this page, and values not published in the documentation are not included.

Part data

Item Value
Part number 2377-3646
Description Filter, sample block, 15 to 25 micron
Recommended stock 1 (1-3 analysers), 2 (4-9), 4 (10 or more)
Related gaskets 3931-7090, 3931-6718, 3931-7083

Host equipment data

Item Value
Analyser family Servomex 700B zirconia oxygen analyser (sensor head plus control unit)
Sensor head ingress classification IP55, safe area unless purged by a suitable system
Control unit ingress classification IP54, safe area unless purged by a suitable system
Sensor head mass 9.0 kg excluding probe tube
Control unit mass 11.5 kg
Sample entry (sensor head) 1/4 inch NPTF
Sensor head to control unit spacing Up to 300 m
Zirconia cell operating temperature 725 degrees C (per the manual)

Typical applications in oil and gas, utilities, water and manufacturing

The 700B is a legacy two-unit flue gas analyser: a heated sensor head mounted on the flue with a probe tube, and a remote control unit. It measures oxygen with a zirconia cell, with an optional combustibles sensor and a flow sensor for the aspirated sample. Many are still running on boilers, process heaters and furnaces. In Oman and the GCC those are found in refineries, power and desalination plants and older petrochemical units where plants keep proven equipment running and need exact spare part numbers.

Gulf conditions add their own demands: high ambient temperature, fine desert dust and coastal humidity all age seals, filters and electronics faster than in temperate climates. A planned stock of spares such as 2377-3646 therefore pays back quickly, because an analyser that is waiting for a part can hold up a start-up, a safety check or an emissions report.

Selection and compatibility notes

The manual recommends 1 for one to three analysers, 2 for four to nine and 4 for ten or more, and lists the related gaskets as separate parts: 3931-7090 for the lower end, 3931-6718 for the fibre top end and 3931-7083 for the PTFE top end. Order matching gaskets with the filter.

The 700B instruction manual lists recommended spares by quantity for one to three analysers, four to nine analysers and ten or more, and notes that some items apply only if options are fitted. Sensor head parts are listed against the exploded view in the manual, so confirm the analyser configuration (with or without combustibles sensor) before ordering.

When you send an enquiry for 2377-3646, include the analyser model, the serial number or order code, the supply voltage if relevant, and a photograph of the nameplate. That information lets us confirm the match against the manufacturer documentation before a quotation is issued.

Installation and commissioning of 2377-3646

Allow the sensor head to cool, isolate power, and follow the manual procedure to open the sample block. Fit the new filter with fresh gaskets and check for leaks after reassembly.

As with any work on process analysers, follow the site permit-to-work system, isolate sample and electrical supplies, and use only the procedures in the manufacturer manual. After fitting 2377-3646, return the analyser to service in the order the manual describes and confirm the reading with a suitable reference gas before relying on the output for control or alarms.

Maintenance and service life

Filter life depends strongly on the dust and condensate content of the flue gas. Inspect at each service and replace on blockage, as indicated by low flow or flow alarms.

Keep a simple maintenance log for each analyser listing the date, the action and the part number used. When 2377-3646 has been changed, a short note makes it easy to plan the next replacement and gives the manufacturer or an engineer useful history if a fault returns.

Related products and ordering notes

Other items from the same manual that are often ordered with 2377-3646 include 00703000 (zirconia oxygen sensor), 00706701 (combustibles sensor and housing assembly), 00705000 (sample flow sensor), 00022907 (flame trap). Each is a separate part number and is quoted separately. Combining them in one enquiry avoids repeated shipments and shortens the shutdown window.

Many of these numbers belong to older analyser generations. If the manufacturer has superseded a part, we will tell you only if the manufacturer documentation names the replacement. Otherwise we will confirm availability and lead time before you commit to an order.

Frequently asked questions

The questions below summarise what buyers most often ask about 2377-3646.

What is 2377-3646? 2377-3646 is the manufacturer part number for the sample block filter used with the Servomex 700B zirconia oxygen analyser (700 series flue gas analyser). It is listed in the spares or parts section of the manufacturer manual.

Which equipment does 2377-3646 fit? It is listed for the Servomex 700B zirconia oxygen analyser (700 series flue gas analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.

Can Seven Star LLC supply 2377-3646 in Oman? Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.

Is a datasheet or manual available for 2377-3646? The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.

What details should I send with my RFQ for 2377-3646? Send the part number 2377-3646, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.

Documents and quotation

The official Servomex 700B Oxygen Analyser Instruction Manual (00700001B) is attached to this page as a PDF. The sensor head spares table (section 7.1.3, figure 7.2, manual page 7.6) lists 2377-3646 as the sample block filter, alongside the matching filter end gaskets. Send us the part number 2377-3646 with the model and serial number of your analyser and we will confirm compatibility and lead time in a written quotation.

Other Models in the Servomex 700B Range

Seven Star LLC supplies models from the Servomex 700B range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Servomex 00703000 Zirconia Oxygen Sensor for Servomex 700BGas Analyzer SystemsView details
Servomex 00706701 Combustibles Sensor Assembly for Servomex 700BGas Analyzer SystemsView details
Servomex 00705000 Flow Sensor for Servomex 700B Sensor HeadGas Analyzer SystemsView details
Servomex 00022907 Flame Trap for Servomex 700B Sensor HeadGas Analyzer SystemsView details
Servomex 2377-3646 Sample Block Filter for Servomex 700BGas Analyzer SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Servomex 700B Oxygen Analyser Instruction Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.

Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.

SERVOMEX company profile

Founded 1952, United Kingdom
Founders Richard Steel, John Crockett and Ronald Mudie
Headquarters Jarvis Brook, Crowborough, East Sussex
Ownership Spectris plc, since 1999
Key technologies Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981)
Product families MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers

Milestones

  • 1952: Servomex is founded.
  • 1961: The first Servomex paramagnetic oxygen analyser is introduced.
  • 1981: Servomex introduces zirconia oxygen sensors.
  • 1999: Spectris acquires Servomex.

Servomex analyzer families listed

Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:

  • SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
  • SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
  • SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
  • SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
  • SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
  • SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer

A flow alarm relay box for the 2700 flue gas analyzer is also listed.

Where Servomex gas analyzers are used

Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.

SERVOMEX products we list

Family Examples
Gas Analyzer Systems SERVOPRO 4900 Multigas Analyzer, SERVOPRO NanoTrace DF-550E Ultra-Trace O…, SERVOTOUGH Laser 3 Plus Combustion TDL G…, SERVOTOUGH OxyExact 2200 Oxygen Analyzer, ServoTough SpectraExact 2500 Gas Analyzer
Portable Test & Measurement Micro i.s. 5100 Portable Oxygen Analyzer
Gas Analyzer Accessories Tough Flue Gas 2700 Flow Alarm Relay Box

Ordering Servomex analyzers and spares: what we need

A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.

Facts checked against Servomex's own 70-year history and company profiles, October 2026.

FAQ

Questions about the Servomex 2377-3646 Sample Block Filter for Servomex

Answers from our engineering team on installation, compatibility and integration.

01What is 2377-3646?
2377-3646 is the manufacturer part number for the sample block filter used with the Servomex 700B zirconia oxygen analyser (700 series flue gas analyser). It is listed in the spares or parts section of the manufacturer manual.
02Which equipment does 2377-3646 fit?
It is listed for the Servomex 700B zirconia oxygen analyser (700 series flue gas analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.
03Can Seven Star LLC supply 2377-3646 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
04Is a datasheet or manual available for 2377-3646?
The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.
05What details should I send with my RFQ for 2377-3646?
Send the part number 2377-3646, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.