Brand:

SEKO Kronos 65 Peristaltic Dosing Pump 25 l/h

Description

The SEKO Kronos 65 is the high-flow stepper-motor peristaltic dosing pump in the Kronos family, supplied here as the KS FM 00 25 M 1 000 version: 25 ml/h to 25 l/h, back pressure to 0.5 bar, 100-240 Vac, Santoprene tube. The pump head is polypropylene, the enclosure ABS, and the motor runs below 35 dB.

In general, a peristaltic pump keeps the chemical inside the tube, which is why this pump type is often chosen for hypochlorite, polymers and viscous liquids (general engineering note, not a datasheet claim).

A peristaltic pump with a wide turn-down ratio

A stepper motor turns a roller rotor that squeezes the tube, and firmware micro-dosing keeps flow accurate down to 25 ml/h while the same pump reaches 25 l/h safely at 0.1 bar. SEKO describes the Kronos series as its most complete and reliable family of peristaltic pumps, able to cope with simple jobs and harsh industrial environments while staying easy to install and cheap to maintain.

Features from the datasheet

  • Flow rate 25 to 25000 ml/h (25 l/h)
  • Enclosure ABS, pump head PP, tube Santoprene
  • Minimum dosing 25 ml/h; safe dosing up to 25 l/h at 0.1 bar
  • Power supply 100-240 Vac, 50/60 Hz, 20 W, with galvanic insulation
  • Back pressure 0.5 to 6 bar across the family; 0.5 bar for this code
  • Stepper motor dosing, accurate, reliable and silent (below 35 dB)
  • Functions: adjustable flow, proportional 4-20 mA, 1:N and N:1, PPM, batch, statistics, password

Technical specification

Parameter Specification
Family and code Kronos 65-WTD, KS FM 00 25 M 1 000
Model and functions FM: adjustable flow rate, manual, 4-20 mA, PPM, 1:n, n:1, batch
Motor noise Below 35 dB
Power supply 100-240 Vac 50/60 Hz, 20 W
Flow range 0.025 to 25 l/h (25 to 25000 ml/h)
Pump head / enclosure Polypropylene / ABS
Tube Santoprene
Maximum back pressure 0.5 bar (7.2 psi)

Understanding the key code

The seven fields are: 1 family KS (Kronos peristaltic pump, high flow rate); 2 model and functions FM (FF on request); 3 maximum back pressure 00 meaning 0.5 bar (02, 03, 06 on request); 4 maximum flow rate 25 meaning 25 l/h (02, 08, 10, 15 on request); 5 power supply M for 100-240 Vac 50/60 Hz 20 W (A to D on request); 6 tube 1 Santoprene (3 Sekoflex, others on request); 7 options 000 standard. This page covers the stocked standard combination KS FM 00 25 M 1 000 only; other combinations are available upon request.

If your process needs more than 0.5 bar, use another Kronos or a diaphragm pump; the datasheet resume table lists only this combination.

Operation and maintenance

The tube is the only wearing part. Replace it on a schedule matched to run hours and chemical, and always use the tube material SEKO specifies for the pump head. Calibrate flow by timing a measured volume, and use the batch mode to deliver a fixed volume per signal. Wall mount the pump so the suction line is short and below the tank where possible.

GCC use cases

Typical uses are sodium hypochlorite at small water systems, polymer and coagulant aid at wastewater skids, antifoam and cleaning chemicals in food plants, and dosing of viscous or abrasive liquids. In summer heat, protect the tube from direct sun and keep chemical temperatures within the tube rating.

Selection and installation notes

A dosing pump is sized from the flow and pressure at the injection point, so confirm the chemical, its concentration and temperature, the head and seal materials, the back pressure and the stroke or speed range before ordering. Fit an injection valve and a suction strainer, keep the suction line short, prime the pump before use, and use a pressure relief valve on the delivery side. Wear the protective equipment named on the chemical safety data sheet when servicing the pump.

A peristaltic pump needs the tube to be replaced at regular intervals, so keep spare tubes in stock and check the tube material against the chemical being dosed.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Accessories and related products

Common add-ons are foot filters, injection valves, suction and delivery tubing and spare tubes. SEKO solenoid and mechanical dosing pumps are alternatives for higher pressure. See Pumps for related equipment.

Frequently asked questions

What flow range does the Kronos 65 give?
25 ml/h to 25 l/h, with minimum dosing of 25 ml/h and safe dosing up to 25 l/h at 0.1 bar.

What is the maximum back pressure for this code?
0.5 bar (7.2 psi) for KS FM 00 25 M 1 000.

What tube material is used?
Santoprene; the key code also lists Sekoflex as an option.

Which control modes are listed?
Adjustable flow, 4-20 mA proportional, 1:N, N:1, PPM, batch, statistics and password.

What supply does it need?
100-240 Vac, 50/60 Hz, 20 W, with galvanic insulation.

Documents and quotation

Quotations for the KRONOS 65 come from Seven Star LLC, independent supplier, Muscat, Oman. Provide the flow in l/h, back pressure, chemical and tube material, the viscosity of the liquid and the tube replacement interval you expect and we will confirm what can be delivered and when. Please confirm the key code and chemical compatibility before ordering. Peristaltic tubes are wear parts in general, so tell us if you want spares quoted. We quote against the key code exactly as printed in the datasheet. For reference, the SEKO Kronos 65-WTD KS technical data sheet rev 2 is available on this page.

Datasheets & Documents
  • PDF Datasheet SEKO Kronos 65-WTD KS technical data sheet rev 2 Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SEKO is an Italian manufacturer of dosing pumps, controllers and dispensing systems, founded in 1976 and headquartered in Santa Rufina, near Rieti. In 1995 the business was taken over by an Italian family, and it is owned and led by the brothers Alessandro Folio (president) and Stefano Folio (CEO). SEKO serves water treatment, industrial processes and professional cleaning and hygiene.

Seven Star LLC is an independent supplier in Muscat. We list SEKO pumps and controllers, each with the manufacturer datasheet, for water treatment and process users in Oman and the GCC.

SEKO company profile

Founded 1976, Italy
Headquarters Santa Rufina, Rieti, Italy
Ownership Folio family, since 1995
Leadership Alessandro Folio (president), Stefano Folio (CEO)
Product families Tekna solenoid dosing pumps (including ATEX versions), Spring mechanical diaphragm and plunger dosing pumps, Kontrol water treatment controllers, side channel blowers, dosing accessories

Milestones

  • 1976: SEKO is founded.
  • 1995: The Folio family takes over the company.

SEKO product series

Solenoid dosing pumps include the Tekna TPG digital pump and the ATEX-marked Tekna for hazardous areas, both for 0.4 to 110 l/h. Motor-driven pumps include the Spring MS1 and compact MSV mechanical diaphragm pumps and the Spring PS1 plunger piston pump for higher pressures. The Kronos 65 is a peristaltic pump with a stepper motor.

The Kontrol 65 and Kontrol 102 controllers measure pH, ORP and conductivity and drive the dosing pumps, and the BL095020 and BL320002 are double impeller side channel blowers.

Where SEKO equipment is used

Chemical feed in cooling towers and boilers, effluent neutralisation, disinfection of potable and process water, swimming pools, aeration and hazardous-area dosing where the ATEX Tekna is specified.

SEKO products we list

Family Examples
Pumps Spring MS1 Mechanical Diaphragm Dosing P…, Spring PS1 Plunger Piston Dosing Pump 1.…, Tekna ATEX Solenoid Dosing Pump 0.4-110…, Tekna TPG Digital Solenoid Dosing Pump 0…
Compressors BL095020 Double Impeller Side Channel Bl…, BL320002 Double Impeller Side Channel Bl…
Liquid Analytical Systems Kontrol 65 Water Treatment Controller 96…

Ordering SEKO pumps and controllers: what we need

Send the flow range, back pressure, chemical and concentration, pump head and seal material, supply voltage and, for pumps with a key code, the complete code as printed in the datasheet.

Facts checked against SEKO's own company pages (seko.com), October 2026.

Frequently Asked Questions

What flow range does the Kronos 65 give?
25 ml/h to 25 l/h, with minimum dosing of 25 ml/h and safe dosing up to 25 l/h at 0.1 bar.
What is the maximum back pressure for this code?
0.5 bar (7.2 psi) for KS FM 00 25 M 1 000.
What tube material is used?
Santoprene; the key code also lists Sekoflex as an option.
Which control modes are listed?
Adjustable flow, 4-20 mA proportional, 1:N, N:1, PPM, batch, statistics and password.
What supply does it need?
100-240 Vac, 50/60 Hz, 20 W, with galvanic insulation.