ebm-papst 4312 Axial Compact Fan 12 V DC, 119 mm

Description

Overview

Meet the ebm-papst 4312: a 119 mm DC axial compact fan from ebm-papst that runs at 2800 rpm from a 12 VDC supply (operating range 6 to 15 VDC). Its housing is glass-fiber reinforced PBT, its impeller is glass-fiber reinforced PA, and the rotor is carried on a ball bearing.

On the performance side the 4312 type gives 170 cubic metres per hour while consuming 5.0 W, and the datasheet states a sound power level of 5.8 B and a sound pressure level of 45 dB(A). The frame is 119 x 119 x 32 mm.

Where does this fan make sense? Anywhere a moderate airflow is needed at low supply voltage, in a space where the 119 mm opening is already available. The 4312 is a straightforward, serviceable choice because its data are fully published and its voltage siblings give you options if the system voltage changes.

Where the ebm-papst 4312 is used

Typical places where the 4312 model is specified in Oman and across the GCC include the following.

  • Medical, laboratory and test equipment where a small, quiet, low-voltage fan is required.
  • LED lighting drivers, signage controllers and display electronics that run at 24 V or 48 V.
  • Telecom and radio shelters, remote terminal units and battery-backed cabinets that run on a low-voltage DC bus.
  • Power electronics such as drives, rectifiers, inverters and converters whose heat sinks need forced convection.

The hot climate, dust and long summers of the region make fan life and sound level significant selection criteria, and the datasheet values for the ebm-papst 4312 give you the figures needed to make that judgment.

Key features of the ebm-papst 4312

A quick read of the data sheet shows these strengths:

  • Airflow of 170 m3/h at the rated point, equal to roughly 100 cfm.
  • Rated power of 5.0 W, or about 0.12 kWh per day of continuous running.
  • Sound power level of 5.8 B and sound pressure level of 45 dB(A).
  • Ambient temperature window from -20 to +70 degrees Celsius.
  • Housing of glass-fiber reinforced PBT plastic and impeller of glass-fiber reinforced PA plastic.
  • Ball bearing with a calculated L10 life of 62,500 hours at 40 degrees Celsius.
  • Protection against reverse polarity and blocked rotor, with locked-rotor and overload protection.
  • Approvals listed: VDE, CSA, UL, CE.

Rated values for the ebm-papst 4312

Every row of this the 4312 fan table is taken from the manufacturer data sheet; the cfm value is a straightforward conversion of the m3/h figure.

Parameter Value
Type 4312
Product group DC axial compact fan
Nominal voltage 12 VDC
Nominal voltage range 6 to 15 VDC
Speed 2800 rpm
Power consumption 5.0 W
Air flow 170 m3/h (100 cfm approx.)
Sound power level 5.8 B
Sound pressure level 45 dB(A)
Ambient temperature range -20 to +70 degrees Celsius
Dimensions 119 x 119 x 32 mm
Weight 0.220 kg
Housing material glass-fiber reinforced PBT plastic
Impeller material glass-fiber reinforced PA plastic
Airflow direction Exhaust over struts
Direction of rotation Clockwise, viewed toward rotor
Bearing Ball bearing
Service life L10 at 40 degrees Celsius 62,500 h
Service life L10 at maximum temperature 30,000 h
Connection Leads AWG 22, TR 64, stripped and tin-plated
Motor protection Protection against reverse polarity and blocked rotor, with locked-rotor and overload protection
Approvals VDE, CSA, UL, CE

How 4312 differs from other DC axial compact fan variants

For the 4312 type, the points that set it apart from the nearest alternatives are listed here with their datasheet numbers.

  • 4314: 24 VDC nominal, 170 m3/h, 5.0 W, 119 x 119 x 32 mm, 45 dB(A).
  • 4318: 48 VDC nominal, 170 m3/h, 5.1 W, 119 x 119 x 32 mm, 45 dB(A).

All three 43xx types deliver the same 170 m3/h at 2800 rpm and share the 119 x 119 x 32 mm frame. The 4312 is the 12 VDC version with a permissible range of 6 to 15 VDC and a rated power of 5.0 W; pick it only when the bus voltage of your equipment matches. Max ambient is 70 degrees Celsius for this type, and the maximum-temperature L10 life is 30,000 hours.

Mechanical design, airflow direction and service life

Physical size and air performance go together for the 4312 model: a 119 mm class frame, 170 cubic metres per hour and 45 dB(A). Weight is 0.220 kg and depth is 32 mm, which tells you how much room to reserve behind the mounting plane. Air leaves the fan over the struts, so any guard or filter on that side should be generous in free area to avoid a loss of flow and an increase in noise.

With a ball bearing and a rotation direction of clockwise viewed toward the rotor, the fan has a published L10 life of 62,500 hours at 40 degrees Celsius (about 7.1 years) falling to 30,000 hours at 70 degrees Celsius (about 3.4 years). Cooler air at the intake gives longer life, so route hot exhaust away from the intake.

Electrical supply and wiring notes for the 4312

Because the ebm-papst 4312 is a DC fan, the supply voltage decides everything about electrical compatibility. It is built for 12 VDC nominal and will operate within 6 to 15 VDC; running it near the lower end of that window reduces airflow and noise, while the upper end increases both. Dividing the rated 5.0 W by the nominal voltage gives a current of roughly 0.42 A, which is a handy figure for fuse and wire sizing, but check the nameplate current and the start-up current on your sample before finalising the protection.

The datasheet states that the fan has protection against reverse polarity and blocked rotor, with locked-rotor and overload protection. In practice this means an accidental polarity swap during wiring or a stalled rotor should not destroy the electronics, although a fan that is repeatedly blocked will still wear out and should be investigated rather than restarted over and over.

The connection is made with leads AWG 22, TR 64, stripped and tin-plated, so a terminal block or a crimped connector must be added by the installer. Optional functions listed for this type are speed signal, alarm signal and Vario-Pro; these are specified at order time and are not part of the plain type.

Keeping the 4312 running

Dust, heat and vibration shorten fan life, so the 4312 fan benefits from a simple routine. Clean the filter or louvre on the intake first, because a clogged filter starves the fan and raises the cabinet temperature. Next, clean the blades. Finally, check the supply with a meter: a drop below the lower end of the allowed range reduces speed and may cause start-up problems.

When replacing the unit, install the same type so that the airflow and mounting remain unchanged, and record the date for the next interval based on the 62,500 hour L10 figure.

Mounting, wiring and first start-up

Installing the 4312 type is straightforward when the basics are respected. Mount the fan on a flat surface using all four fixing holes, and use screws of the correct length so they do not protrude into the impeller. Keep the 32 mm depth in mind when you check clearance behind the cut-out, and ensure leads cannot touch the rotating impeller. Check the arrow on the housing for airflow and rotation direction before tightening the screws.

Commissioning means applying the nominal supply and listening for abnormal noise, checking that the airflow is on the expected side, and confirming the temperature inside the enclosure falls to the design level after thirty minutes of operation.

Ordering information and RFQ details

To obtain a quotation for the 4312, send the part number, quantity, the required delivery point in Oman or elsewhere in the GCC, and, if available, a photo of the existing fan label. If the equipment is old, include the machine model; this helps us confirm that the supply voltage and mounting dimensions are right.

For multiple voltage versions of the same fan family, list each type on a separate line so that quantities do not get mixed up.

Related items you may also need: ebm-papst Industrial Cooling Fan | ebm-papst R1G225-AF11-52 DC Fan | ebm-papst 4650 N AC Axial Compact Fan 119 mm 230 V | All ebm-papst products.

Documents and quotation

Before you place an order, open the datasheet linked on this page and compare the nominal data of the ebm-papst 4312 with your application. Seven Star LLC is an independent supplier serving Oman and the GCC. When you are ready, send an RFQ stating the part number 4312, the quantity and the delivery point, and our team will confirm availability and lead time.

If your project needs several fan types, we can quote them in one offer; just list each type and quantity on its own line.

Other Models in the Ebm Compact Axial Range

Seven Star LLC supplies models from the Ebm Compact Axial range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ebm-papst 3956 Axial Panel Compact Fan 230 V AC, 92 mmIndustrial Fans & BlowersView details
ebm-papst 5900 Axial Compact Fan 115 V AC, 127 mmIndustrial Fans & BlowersView details
ebm-papst 4312 Axial Compact Fan 12 V DC, 119 mmIndustrial Fans & BlowersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet ebm-papst 4312 Axial Compact Fan 12 V DC, 119 mm Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ebm-papst is a German family-owned maker of fans and motors, headquartered in Mulfingen. It was founded in 1963 by Gerhard Sturm and Heinz Ziehl as Elektrobau Mulfingen (ebm) and took its current name after acquiring Papst in 1992. ebm-papst makes EC fans, blowers and motors for ventilation, cooling and air conditioning.

Seven Star LLC is an independent supplier in Muscat. We list ebm-papst fans for equipment cooling in Oman and the GCC.

ebm-papst company profile

Founded 1963, Mulfingen, Germany
Founders Gerhard Sturm and Heinz Ziehl
Headquarters Mulfingen, Germany
Ownership Family-owned
Product families RadiCal and R1G EC centrifugal fans, axial fans, compact DC fans, EC motors

Milestones

  • 1963: Elektrobau Mulfingen is founded.
  • 1992: ebm acquires Papst and becomes ebm-papst.

ebm-papst product series

Centrifugal fans include the R1G175-AB41-02 and R1G225-AF11-52 DC fans with backward curved impellers. Papst industrial cooling fans are used in cabinets and electronics.

Replacements should match the part number exactly, as size, voltage, airflow, speed signal and connector can differ between versions. EC fans can be speed controlled to save energy and reduce noise.

Where ebm-papst fans are used

Cooling of drives, UPS, telecom and control cabinets, HVAC units and electronic equipment.

ebm-papst products we list

Family Examples
Cooling R1G175-AB41-02 DC Fan, R1G225-AF11-52 DC Fan
Automation Accessories Papst Industrial Cooling Fan

Ordering ebm-papst fans: what we need

Send the full part number from the label, voltage and quantity.

Facts checked against ebm-papst's published company history, October 2026.

FAQ

Questions about the ebm-papst 4312 Axial Compact Fan 12 V DC, 119 mm

Answers from our engineering team on installation, compatibility and integration.

01What supply does the ebm-papst 4312 need?
The ebm-papst 4312 is rated for 12 VDC with a permissible range of 6 to 15 VDC, and the rated power is 5.0 W at 2800 rpm.
02How much air does the ebm-papst 4312 move and how loud is it?
The datasheet gives 170 m3/h at the rated point, a sound power level of 5.8 B and a sound pressure level of 45 dB(A).
03What ambient temperature can the ebm-papst 4312 work in?
The ambient range in the datasheet is -20 to +70 degrees Celsius. Calculated L10 life is 62,500 hours at 40 degrees Celsius and 30,000 hours at the maximum temperature.
04What are the dimensions and material of the ebm-papst 4312?
The frame measures 119 x 119 x 32 mm and weighs 0.220 kg. The housing is glass-fiber reinforced PBT plastic and the impeller is glass-fiber reinforced PA plastic; air leaves the fan over the struts.
05How do I request a quotation for the ebm-papst 4312?
Send an RFQ to Seven Star LLC with the type 4312, the quantity and the delivery location in Oman or the GCC; a datasheet is attached to the product page for reference.