Brand:

Bürkert 126417 Type 6106 3/2-Way Rocker Solenoid Valve 24 V DC

Description

Overview

Pneumatic circuits that switch small cylinders, grippers and pilot lines often need a valve that is little more than a thumb wide. The Bürkert 126417 is one such valve: a direct-acting 3/2-way rocker solenoid valve from Bürkert Type 6106, normally closed, with a 0.9 mm orifice, a 24 V DC coil of 1 W and a sub-base mounting face. Its housing is only 16 mm wide, so a row of them fits on a manifold the size of a paperback. Seven Star LLC is an independent supplier serving Oman and the GCC.

What the article number stands for

Type 6106 is offered in two circuit functions and two orifice sizes, and each combination with a specific sub-base has its own number. The Bürkert 126417 is circuit function C, the normally closed version, with the Bürkert sub-base interface of 16 by 27 mm and the 0.9 mm orifice. Its sibling for the CNOMO lateral sub-base is 126418, and both are supplied with side plug contacts, a manual override, the sub-base seals and fastening screws of M2.5 by 16 mm.

The manual override matters during commissioning, since it lets a technician move the air without electrical power. The data sheet notes that variants without it are also available as an option.

Data for Bürkert 126417

Item Value
Article number 126417
Circuit function C, 3/2-way, normally closed
Port connection Bürkert sub-base 16 x 27 mm
Orifice DN 0.9
Nominal power 1 W
Flow QNn, 1 to 2 22 l/min
Flow QNn, 2 to 3 25 l/min
Pressure range vacuum to 8 bar
Valve body / seal polyamide / FKM
Operating voltage 24 V DC, tolerance plus/minus 10 percent
Duty cycle 100 percent continuous operation
Medium neutral gases, 5 micrometre filtering
Medium and ambient temperature minus 10 to plus 55 degrees C
Switching frequency approx. 16 Hz
Electrical connection plug contacts to DIN EN 175301-803 form C, cable plug Type 2516 or rectangular plug Type 2505 (ordered separately)
Degree of protection IP65 with cable plug Type 2516; IP30 with rectangular plug Type 2505
Width 16 mm
Optional approval ATEX / IECEx Ex ia IIC T5, T6 Gb on request (explosion-proof variant draws 0.5 W)

Flow and pressure in practice

At the datasheet test condition of 6 bar at the inlet and a differential of 1 bar, the valve delivers a standard nominal flow of 22 litres per minute from port 1 to 2 and 25 litres per minute from 2 to 3. For small single-acting cylinders, that is enough to move a piston of a few millilitres within a fraction of a second. The pressure range runs from vacuum to 8 bar, so the same valve can be used for vacuum handling as well as for positive pressure. The explicitly listed medium is neutral gas filtered to 5 micrometres.

How Bürkert 126417 differs from other Type 6106 variants

Four numbers describe the neighbourhood. The 1.2 mm normally closed valve on the same Bürkert sub-base, 126411, raises the flow to 40 and 47 litres per minute and the power to 2 W, with a pressure limit of 10 bar. The normally open versions replace the closed seat with an open one: 126421 for 0.9 mm and 126419 for 1.2 mm. So this 126417 is the smallest, lowest-power, normally closed member of the Bürkert sub-base group and should be chosen where economy of power and space matters more than flow.

Applications

In Oman and the wider GCC, valves of this kind sit inside analytical instruments, packaging machines, sample-handling systems and small automation cells. They are also widely used as pilot valves for pneumatic actuators on process valves at oil and gas sites, because the 1 W coil can be driven directly by many PLC output cards and low-power sources. The ATEX and IECEx Ex ia variant, available on request, extends the family to intrinsically safe circuits in hazardous areas.

Mounting and wiring

Place the valve on the matching Bürkert sub-base with its seals in the grooves, then tighten the two screws evenly. Plug a cable plug of Type 2516 onto the form C contacts for IP65 protection; a rectangular plug of Type 2505 only reaches IP30. Neither plug is included, so order one together with the valve. Connect 24 V DC, observing the polarity marking, and keep the supply within plus/minus 10 percent including any ripple.

Use clean, dry, filtered air. Particles larger than 5 micrometres can lodge on the small seat and are the most common reason for leakage in valves of this size.

Selecting the right sub-base and plug

Most mistakes with miniature valves come from the interface and not from the valve itself. The Bürkert sub-base and the CNOMO sub-base have different hole patterns, so the two are not interchangeable, and a valve ordered for the wrong one simply will not seal on the manifold. Check which manifold is already on the machine, count the number of stations and note whether the manifold is a single or multiple type, because the datasheet lists matching manifold bodies for each. Then decide on the electrical side: flying leads of 500 mm give a compact and sealed connection, the form C cable plug gives IP65 and is easy to exchange, and the rectangular plug saves space inside a cabinet but offers only IP30. If the machine will be washed down or installed outdoors, choose a connection with IP65 protection.

Care of small pneumatic valves

The design is made for a high number of cycles, so the usual failure is contamination and not wear. Fit and maintain a fine filter ahead of the manifold, drain the condensate regularly and avoid lubricated air unless the datasheet allows it. When replacing a valve on a manifold, shut the supply, vent the system, and renew the sub-base seals at the same time.

Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Moog 072-1201 Servo Valve, 95 l/min, ISO 10372 Size 06 | All Bürkert products.

Documents and quotation

The Type 6106 datasheet, with circuit functions, materials, dimensions and the manifold accessories, is attached. Send your RFQ with Bürkert 126417, the quantity, and the plug type you need, and tell us the delivery place in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Bürkert 126417 Type 6106 3/2-Way Rocker Solenoid Valve 24 V DC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 126417 Type 6106 3/2-Way Rocker Solenoid

Answers from our engineering team on installation, compatibility and integration.

01Which circuit function does the Bürkert 126417 have?
Circuit function C: a direct-acting 3/2-way valve that is normally closed, with ports 1 (P), 2 (A) and 3 (R).
02What flow does the Bürkert 126417 deliver?
With its 0.9 mm orifice it gives a standard nominal flow of 22 l/min from 1 to 2 and 25 l/min from 2 to 3 at 6 bar.
03What coil power and voltage does the 126417 use?
It uses a 24 V DC coil of 1 W with plus/minus 10 percent tolerance and a 100 percent duty cycle.
04Does the Bürkert 126417 include a cable plug?
No, connectors for the form C or rectangular plugs are not included and must be ordered separately as accessories.
05What is the difference between 126417 and 126418?
Both are the same normally closed 0.9 mm valve; 126417 fits the Bürkert sub-base, while 126418 fits the CNOMO lateral sub-base.