Brand:

APC SUA48XLBP Smart-UPS XL Battery Pack Tower/Rack Convertible

Description

What the SUA48XLBP is for

APC SUA48XLBP is catalogued by APC as Smart-UPS XL Battery Pack Tower/Rack Convertible 48V rackmount with kit 5U.

Chemistry: lead-acid battery. Each unit measures 444 mm x 221 mm x 495 mm (H x W x D) and weighs 66.36 kg.

Technical specifications

Parameter Specification
Part number SUA48XLBP
Main Input Voltage 48 V DC
Product or component type External battery pack
Number of cables 1
Battery type Lead-acid battery
Range of product Smart-UPS Battery Systems
Mounting preference No preference
Mounting mode Rack-mounted with kit
Number of rack unit 5U
Number of power module free slots 0
Number of power module filled slots 0
Redundant No
Additional information For use with "SUA" 2200/3000VA 5U rack/tower models. Can be used with 3U models with SUA039 extension cable.
Graph display 1
Show note OP temperature No
Liquid value 0
Battery curve B
Extended runtime 0
Replacement battery RBC55
Height 444 mm
Width 221 mm
Depth 495 mm
Net weight 66.36 kg
USB compatible No
Battery life 3…5 year(s)
Number of battery filled slots 0
Number of battery free slots 0
Number of battery replacement quantity 2
Relative humidity 0…95 %
Storage Relative Humidity 0…95 %
Ambient air temperature for storage -15…45 °C
Ambient air temperature for operation 0…40 °C
Operating altitude 0…10000 ft
Storage altitude 0…15240 m
Warranty (in months) 24

Battery data and handling

Replacement reference: RBC55. Battery life: 3…5 year(s).

Battery replacement should be matched to the exact UPS model named in the APC documentation, because voltage, connector and cartridge count differ between systems. Used batteries must be recycled according to local regulations.

Installation space and operating limits

Dimensions are 444 mm x 221 mm x 495 mm (H x W x D), and the unit weighs 66.36 kg.

Listed operating limits: operating temperature 0…40 °C; relative humidity 0…95 %; operating altitude 0…10000 ft.

Warranty recorded by APC (months): 24.

The APC SUA48XLBP is listed with type lead-acid battery, battery life 3…5 year(s). Replacement batteries should be fitted as a complete set of the same type and age, because mixing old and new cells shortens the life of the whole string. Fit and wire the cartridge exactly as shown in the installation sheet, and recycle used batteries according to local regulations.

Communication and management details listed: graph display: 1. Network cards, software and monitoring options should be matched to the facility monitoring system before ordering.

The unit measures 444 mm x 221 mm x 495 mm (H x W x D) and weighs 66.36 kg, so check the available space and the handling requirements before delivery. It occupies 5U of rack space. Listed environmental limits: operating temperature 0…40 °C; relative humidity 0…95 %; altitude 0…10000 ft. Store and operate the battery within these limits, because heat shortens service life.

The warranty period recorded in the product data is 24 months. If a project requires certificates or test reports, include that request with the quotation request.

Where the SUA48XLBP fits in an APC Smart-UPS XL installation

Smart-UPS XL models are the extended-runtime versions of the line-interactive Smart-UPS. They keep the internal battery of a standard unit and add a connector for external battery packs, so runtime can be extended from minutes to hours for telecom cabinets, security systems and remote sites.

An external battery pack adds runtime by connecting additional battery strings to the DC bus of a compatible UPS. The pack voltage and connector must match the UPS, and the UPS should be told how many packs are connected so that runtime estimates and charging stay correct. Packs are normally daisy-chained, so the total runtime can be built up step by step as the load or the outage risk of the site grows.

In the product data for the APC SUA48XLBP, its battery technology is listed as lead-acid battery; it occupies 5U rack unit(s). These values are the starting point for matching it to the rest of the installation.

Using the SUA48XLBP in Gulf climate and grid conditions

The listed operating temperature tops out at 40 °C. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, so the equipment belongs in an air-conditioned room or cabinet rather than an open plant area. Battery temperature has the biggest effect on service life: as a rule of thumb, the life of a valve-regulated lead-acid battery roughly halves for every 10 °C above 25 °C, so a room held at 20 to 25 °C pays back in fewer battery replacements. Fine dust inland and humid, salty air on the coast are hard on electronics, so a sealed room, clean filters and periodic inspection of fans and terminals are part of a reliable installation. At 66.36 kg the unit needs two people or lifting equipment for installation, and rails rather than a shelf if it goes into a rack.

Information to include when ordering the SUA48XLBP

The following details help confirm compatibility before a quotation is issued:

  • The exact UPS model the pack will be connected to
  • How many packs are already connected and how many are needed
  • The runtime target at the actual load
  • Rack or tower installation and available rack units
  • The delivery location in Oman (for example Muscat, Sohar, Duqm or Salalah) or elsewhere in the GCC, and the required date

The replacement battery for this unit is the APC RBC55, which can be quoted together with the UPS or kept as a spare.

Other APC UPS systems, batteries and accessories and Schneider Electric equipment can be combined in one quotation.

Documents and quotation

The user guide for the SUA48XLBP is hosted on this page under Documents so the wiring, installation and operating details can be reviewed before ordering.

The single-unit shipping package is listed as 52 cm (height) x 60 cm (width) x 77 cm (length) with a packed weight of 81 kg. Use these values when planning freight, lifting and receiving space.

To order, submit the part number SUA48XLBP, the quantity and the delivery location. Related items are grouped under UPS and Batteries. Seven Star LLC is an independent supplier based in Muscat and answers with availability and a quotation.

Datasheets & Documents
  • PDF User guide APC SUA48XLBP User guide Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

APC is Schneider Electric's brand for uninterruptible power supplies, power distribution units, cooling and racks for IT and control systems. American Power Conversion was founded in 1981 by three engineers from MIT's Lincoln Laboratory and grew into one of the largest UPS makers in the world. Schneider Electric completed its acquisition of APC on 14 February 2007, combined it with MGE UPS Systems, and since 2011 APC has been a product brand of Schneider Electric.
Seven Star LLC lists APC uninterruptible power supplies from desktop Back-UPS units to modular Symmetra systems, together with battery packs and network cards, and sources them for sites in Oman.

APC company profile
Founded1981, USA, as American Power ConversionFoundersThree engineers from MIT Lincoln LaboratoryOwnershipSchneider Electric since 14 February 2007; an APC by Schneider Electric product brand since 2011Product familiesBack-UPS, Easy UPS, Smart-UPS line-interactive, Smart-UPS On-Line SRT and SRV, Galaxy three-phase UPS, rack PDUs, NetShelter racks, network management cards and EcoStruxure IT software

Milestones
1981: American Power Conversion is founded by three MIT Lincoln Laboratory engineers.2006: Schneider Electric announces the acquisition of APC on 30 October.2007: The acquisition is completed on 14 February; APC is combined with MGE UPS Systems.2011: APC becomes a product brand within Schneider Electric.

APC UPS families on this page

APC names its UPS lines by topology and size:

Back-UPS and Back-UPS Pro: line-interactive units for workstations and small loads, such as BX1600MI-MS and BR1600MISmart-UPS: line-interactive models with sine wave output, including SMT750I, SMC1000IC and the Smart-UPS X SMX3000HV with its SMX120BP external battery packSmart-UPS SRT and Smart-UPS RT: online double-conversion units, for example SRT2200XLI, SRT3000XLI, SRT5KRMXLI and SURT8000XLIEasy UPS Online: SRV2KILSymmetra LX and Symmetra PX: modular, scalable systems for larger loads

The AP9641 Network Management Card 3 adds remote monitoring to UPS models with a SmartSlot.

Where APC UPS systems are used

In industrial plants across the GCC, APC UPS units back up DCS and PLC cabinets, operator stations, SCADA servers, telecom racks, fire and gas panels and analyzer shelters. Online double-conversion models are normally chosen for control systems because the load is always fed through the inverter. Line-interactive units suit office IT and less critical loads.

APC products we list
FamilyExamplesUPS and BatteriesAP9641 Network Management Card 3, BR1600MI Back-UPS Pro 1600VA/960W, BX1600MI-MS Back-UPS 1600VA Tower UPS, SMC1000IC Line-Interactive UPS 1000VA 600W, SMC1500I Smart-UPS C 1500VA/900W, SMT750I Smart-UPS 750VA/500W Line-Interactive, SMX120BP Smart-UPS X 120V External Battery, SMX1500RMI2U Smart-UPS X 1500VA Rack/Tower and 9 more

Ordering APC UPS units and parts: what we need

Send the full SKU, for example SRT3000XLI, and not only the VA rating. The letters carry meaning: an I in the suffix marks a 230 V international model, XL an extended-run version that accepts external battery packs, and RM a rack-mount form. For a new requirement, give load in watts, input and output voltage, required runtime, tower or rack format, and the plug or hardwire arrangement. For batteries, send the UPS SKU and serial number so the correct replacement battery cartridge can be found in APC documentation.

Replacement batteries, battery packs and spares
Most APC service work is battery work. APC Replacement Battery Cartridges, sold under RBC and APCRBC numbers, are sets of sealed valve-regulated lead-acid blocks that arrive pre-wired with the connectors for the UPS models they are listed for, so a weak battery can be changed as one unit and, on hot-swap models, without switching the load off. Some newer cartridges carry an -LI suffix for lithium-ion versions. External battery packs extend runtime on XL and SRT models, and are chained to the UPS through the battery connector on the rear panel. To find the right cartridge, send the UPS SKU and serial number; the same UPS can use different cartridges across hardware revisions.
Modular and three-phase APC systems
Symmetra LX and Symmetra RM: single-phase modular UPS frames with hot-swappable power modules, battery modules and intelligence modules, so a failed module can be exchanged while the load stays on protected power.Symmetra PX: three-phase modular UPS for data rooms, built from power modules with N+1 redundancy and battery modules for runtime.Smart-UPS VT: three-phase double-conversion UPS for small data rooms and technical buildings.Silcon: large three-phase UPS based on delta conversion, still running in many plants and data centres; spare part kits are listed in levels (SPL1 to SPL4) so sites can hold the parts that match their service plan.Easy UPS On-Line (SRV): cost-focused double-conversion units, many with external battery pack support.
APC UPS in Oman and GCC conditions
Oman supplies 240 V single-phase and 415 V three-phase at 50 Hz, so international models with an I suffix (230 V nominal, adjustable to 240 V on most Smart-UPS units) are the usual choice. Heat is the main enemy: most APC UPS units are rated for operation up to 40 °C, while summer shade temperatures in Muscat and the interior pass 45 °C, and a lead-acid battery loses roughly half its service life for every 10 °C above 25 °C. Install UPS and batteries in a cooled room, keep filters clean in dusty inland sites, and size the standby generator with margin for UPS input and battery charging current.
All APC UPS systems, batteries and accessories on this site are grouped under UPS and Batteries, and the wider Schneider Electric range can be quoted together with them.

Facts checked against APC by Schneider Electric's published history, October 2026.

Browse APC products by category: UPS and Batteries.
Need a replacement battery for an APC UPS you already run? Use our APC UPS replacement battery finder to match the model to its official RBC cartridge.

FAQ

Questions about the APC SUA48XLBP Smart-UPS XL Battery Pack Tower/Rack

Answers from our engineering team on installation, compatibility and integration.

01What is the APC SUA48XLBP?
APC lists the APC SUA48XLBP as: Smart-UPS XL Battery Pack Tower/Rack Convertible 48V rackmount with kit 5U.
02Which battery type is used with the APC SUA48XLBP?
The recorded battery type is lead-acid battery.
03What are the dimensions and weight of the APC SUA48XLBP?
The listed dimensions are 444 mm x 221 mm x 495 mm (H x W x D) and the weight is 66.36 kg.
04What operating conditions apply to the APC SUA48XLBP?
Listed limits: operating temperature 0…40 °C; relative humidity 0…95 %.
05How can I request a quotation for the APC SUA48XLBP?
Send the part number SUA48XLBP with quantity and delivery location through the RFQ form. Seven Star LLC is an independent supplier in Muscat and replies with availability and a quotation.