Brand: APC
APC SBPAR3I15K20R2M2WP Parallel Maintenance Bypass for 2 UPS
Description
SBPAR3I15K20R2M2WP bypass panel overview
The APC SBPAR3I15K20R2M2WP is catalogued by APC as Parallel Maintenance Bypass for 2 UPS (1+1) 3:1 15-20kVA Wallmount.
Supplied items listed by APC: installation guide.
The listed supplied items are: installation guide.
Technical specifications
| Parameter | Specification |
|---|---|
| Part number | SBPAR3I15K20R2M2WP |
| Main Input Voltage | 400 V 3 phases |
| Main Output Voltage | 220 V |
| Other Output Voltage | 230 V |
| Output connector type | Hard wire 3-wire (H N + E) for 1 zone(s) |
| Provided equipment | Installation guide |
| Height | 120 cm |
| Width | 101 cm |
| Depth | 80 cm |
| Net weight | 100 kg |
| Mounting location | Front |
| Mounting preference | No preference |
| Mounting mode | Rack-mounted |
| Standards | EN 50091-2 / EN/IEC 62040-1-1 / EN/IEC 62040-3 / VFI-SS-111 |
| Ambient air temperature for operation | 0…40 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0…10000 ft |
| Ambient air temperature for storage | -15…45 °C |
| Storage Relative Humidity | 0…95 % |
| Storage altitude | 0…9144 m |
| Warranty (in months) | 12 |
Compatibility and fitting notes
Input voltage: 400 V 3 phases. Output voltage: 220 V.
Check the exact compatible UPS model and the installation sheet before ordering, because accessory kits, cables and options are specific to a given system or range.
Site requirements and approvals
Dimensions are 120 cm x 101 cm x 80 cm (H x W x D), and the unit weighs 100 kg.
Listed operating limits: operating temperature 0…40 °C; relative humidity 0…95 %; operating altitude 0…10000 ft.
Standards: EN 50091-2 / EN/IEC 62040-1-1 / EN/IEC 62040-3 / VFI-SS-111. Warranty recorded by APC (months): 12.
The mounting mode is listed as rack-mounted. The unit measures 120 cm x 101 cm x 80 cm (H x W x D) and weighs 100 kg, so check the available space and the floor or rack loading before delivery. Rack installation should be checked against the rack depth, rail kit and the clearance needed behind the unit for cables and airflow. Listed environmental limits: operating temperature 0…40 °C; relative humidity 0…95 %; altitude 0…10000 ft. Equipment rooms in the Gulf region often run warm, so leave ventilation clearance and keep the unit away from direct heat sources.
The warranty period recorded in the product data is 12 months. If a project requires certificates or test reports, include that request with the quotation request.
How the SBPAR3I15K20R2M2WP is used in APC systems
APC by Schneider Electric is one of the most widely installed UPS brands worldwide, covering single-phase and three-phase UPS systems, replacement batteries, battery packs, management cards and installation accessories.
A maintenance bypass lets the protected load be transferred from the UPS output to the incoming supply, so the UPS can be serviced, tested or replaced without shutting the load down. The transfer is made in a defined sequence so the load is never interrupted, and the panel is wired to match the voltage, current and number of UPS units in the installation.
Applying the SBPAR3I15K20R2M2WP on sites in Oman and the GCC
Low-voltage three-phase networks in Oman run at a nominal 415 V, 50 Hz, and most GCC countries at 400 V or 415 V, so confirm that the input voltage window of the system covers the measured supply on site. The listed operating temperature tops out at 40 °C. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, so the equipment belongs in an air-conditioned room or cabinet rather than an open plant area. Coastal sites such as Muscat, Sohar and Duqm add humidity and salt to the air, and inland sites add fine dust, so keep the room sealed and clean and check filters and fans at every service visit. At 100 kg the unit needs two people or lifting equipment for installation, and rails rather than a shelf if it goes into a rack.
Service life and maintenance of the APC SBPAR3I15K20R2M2WP
Reliability over the years depends mostly on the environment and on routine checks. Keep the room cool and dust-free, inspect fans, filters and connections during planned visits, and review the event log for warnings. On UPS and battery systems, measure runtime under the real load from time to time and replace batteries as a complete set before the runtime falls below what the site needs.
Seven Star LLC supplies APC equipment as an independent supplier based in Muscat. Original product documents are provided where available, and the part number SBPAR3I15K20R2M2WP can be quoted together with related batteries, accessories and spares in one enquiry.
Storage, handling and delivery of the APC SBPAR3I15K20R2M2WP
Electronic assemblies and accessories should be stored in their original packaging in a dry, temperature-controlled area until installation, away from dust and condensation. Check the packaging and the part number label on arrival, keep the documents supplied with the item, and record the installation date so that future service intervals and warranty questions can be answered quickly. Seven Star LLC arranges delivery to project sites, warehouses and offices across Oman, and shipment to other GCC countries on request.
What to send with an enquiry for the SBPAR3I15K20R2M2WP
The following details help confirm compatibility before a quotation is issued:
- The UPS model and serial number the item will be used with
- The quantity needed, including any spares to keep on site
- Rack, room or panel details where the item will be installed
- Any documents or certificates required for the project
- The delivery location in Oman (for example Muscat, Sohar, Duqm or Salalah) or elsewhere in the GCC, and the required date
Other APC UPS systems, batteries and accessories and Schneider Electric equipment can be combined in one quotation.
Documents and quotation
The user guide for the SBPAR3I15K20R2M2WP is hosted on this page under Documents so the wiring, installation and operating details can be reviewed before ordering.
The single-unit shipping package is listed as 120 cm (height) x 101 cm (width) x 80 cm (length) with a packed weight of 100 kg. Use these values when planning freight, lifting and receiving space.
To order, submit the part number SBPAR3I15K20R2M2WP, the quantity and the delivery location. Related items are grouped under UPS and Batteries. Seven Star LLC is an independent supplier based in Muscat and answers with availability and a quotation.
Datasheets & Documents
- User guide APC SBPAR3I15K20R2M2WP User guide Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
APC is Schneider Electric's brand for uninterruptible power supplies, power distribution units, cooling and racks for IT and control systems. American Power Conversion was founded in 1981 by three engineers from MIT's Lincoln Laboratory and grew into one of the largest UPS makers in the world. Schneider Electric completed its acquisition of APC on 14 February 2007, combined it with MGE UPS Systems, and since 2011 APC has been a product brand of Schneider Electric.
Seven Star LLC lists APC uninterruptible power supplies from desktop Back-UPS units to modular Symmetra systems, together with battery packs and network cards, and sources them for sites in Oman.
APC company profile
Founded1981, USA, as American Power ConversionFoundersThree engineers from MIT Lincoln LaboratoryOwnershipSchneider Electric since 14 February 2007; an APC by Schneider Electric product brand since 2011Product familiesBack-UPS, Easy UPS, Smart-UPS line-interactive, Smart-UPS On-Line SRT and SRV, Galaxy three-phase UPS, rack PDUs, NetShelter racks, network management cards and EcoStruxure IT software
Milestones
1981: American Power Conversion is founded by three MIT Lincoln Laboratory engineers.2006: Schneider Electric announces the acquisition of APC on 30 October.2007: The acquisition is completed on 14 February; APC is combined with MGE UPS Systems.2011: APC becomes a product brand within Schneider Electric.
APC UPS families on this page
APC names its UPS lines by topology and size:
Back-UPS and Back-UPS Pro: line-interactive units for workstations and small loads, such as BX1600MI-MS and BR1600MISmart-UPS: line-interactive models with sine wave output, including SMT750I, SMC1000IC and the Smart-UPS X SMX3000HV with its SMX120BP external battery packSmart-UPS SRT and Smart-UPS RT: online double-conversion units, for example SRT2200XLI, SRT3000XLI, SRT5KRMXLI and SURT8000XLIEasy UPS Online: SRV2KILSymmetra LX and Symmetra PX: modular, scalable systems for larger loads
The AP9641 Network Management Card 3 adds remote monitoring to UPS models with a SmartSlot.
Where APC UPS systems are used
In industrial plants across the GCC, APC UPS units back up DCS and PLC cabinets, operator stations, SCADA servers, telecom racks, fire and gas panels and analyzer shelters. Online double-conversion models are normally chosen for control systems because the load is always fed through the inverter. Line-interactive units suit office IT and less critical loads.
APC products we list
FamilyExamplesUPS and BatteriesAP9641 Network Management Card 3, BR1600MI Back-UPS Pro 1600VA/960W, BX1600MI-MS Back-UPS 1600VA Tower UPS, SMC1000IC Line-Interactive UPS 1000VA 600W, SMC1500I Smart-UPS C 1500VA/900W, SMT750I Smart-UPS 750VA/500W Line-Interactive, SMX120BP Smart-UPS X 120V External Battery, SMX1500RMI2U Smart-UPS X 1500VA Rack/Tower and 9 more
Ordering APC UPS units and parts: what we need
Send the full SKU, for example SRT3000XLI, and not only the VA rating. The letters carry meaning: an I in the suffix marks a 230 V international model, XL an extended-run version that accepts external battery packs, and RM a rack-mount form. For a new requirement, give load in watts, input and output voltage, required runtime, tower or rack format, and the plug or hardwire arrangement. For batteries, send the UPS SKU and serial number so the correct replacement battery cartridge can be found in APC documentation.
Replacement batteries, battery packs and spares
Most APC service work is battery work. APC Replacement Battery Cartridges, sold under RBC and APCRBC numbers, are sets of sealed valve-regulated lead-acid blocks that arrive pre-wired with the connectors for the UPS models they are listed for, so a weak battery can be changed as one unit and, on hot-swap models, without switching the load off. Some newer cartridges carry an -LI suffix for lithium-ion versions. External battery packs extend runtime on XL and SRT models, and are chained to the UPS through the battery connector on the rear panel. To find the right cartridge, send the UPS SKU and serial number; the same UPS can use different cartridges across hardware revisions.
Modular and three-phase APC systems
Symmetra LX and Symmetra RM: single-phase modular UPS frames with hot-swappable power modules, battery modules and intelligence modules, so a failed module can be exchanged while the load stays on protected power.Symmetra PX: three-phase modular UPS for data rooms, built from power modules with N+1 redundancy and battery modules for runtime.Smart-UPS VT: three-phase double-conversion UPS for small data rooms and technical buildings.Silcon: large three-phase UPS based on delta conversion, still running in many plants and data centres; spare part kits are listed in levels (SPL1 to SPL4) so sites can hold the parts that match their service plan.Easy UPS On-Line (SRV): cost-focused double-conversion units, many with external battery pack support.
APC UPS in Oman and GCC conditions
Oman supplies 240 V single-phase and 415 V three-phase at 50 Hz, so international models with an I suffix (230 V nominal, adjustable to 240 V on most Smart-UPS units) are the usual choice. Heat is the main enemy: most APC UPS units are rated for operation up to 40 °C, while summer shade temperatures in Muscat and the interior pass 45 °C, and a lead-acid battery loses roughly half its service life for every 10 °C above 25 °C. Install UPS and batteries in a cooled room, keep filters clean in dusty inland sites, and size the standby generator with margin for UPS input and battery charging current.
All APC UPS systems, batteries and accessories on this site are grouped under UPS and Batteries, and the wider Schneider Electric range can be quoted together with them.
Facts checked against APC by Schneider Electric's published history, October 2026.
Browse APC products by category: UPS and Batteries.
Need a replacement battery for an APC UPS you already run? Use our APC UPS replacement battery finder to match the model to its official RBC cartridge.
Related products
Frequently Asked Questions
APC lists the APC SBPAR3I15K20R2M2WP as: Parallel Maintenance Bypass for 2 UPS (1+1) 3:1 15-20kVA Wallmount.
APC lists these supplied items: installation guide.
The listed dimensions are 120 cm x 101 cm x 80 cm (H x W x D) and the weight is 100 kg.
Listed limits: operating temperature 0…40 °C; relative humidity 0…95 %.
Send the part number SBPAR3I15K20R2M2WP with quantity and delivery location through the RFQ form. Seven Star LLC is an independent supplier in Muscat and replies with availability and a quotation.